SN/T 1431.6-2012Rules for the inspection of low-voltage appliances for import and export. Part 6: Energy efficiency of AC contactor (English PDF)
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for SN/T 1431.6-2012 in 30 minutes.
Issued by
General Administration of Customs
Level / Type
National · Recommended
Issue date
October 23, 2012
Implementation date
May 1, 2013
Scope
SN/T 1431.6-2012 (Rules for the inspection of low-voltage appliances for import and export. Part 6: Energy efficiency of AC contactor) is available as an English-translated PDF.
SN/T 1431.6-2012 - SN/T 1431 This section provides import and export of exchanges and contacts with energy efficiency requirements, sampling, testing and the results of determination.
This part of the direct drive rated frequency 50Hz, rated working voltage of 380V (400V), rated current of 6A ~ 630A Style, three-pole electric, AC contactor integral.
This section does not apply to additional energy-saving devices, for household and similar purposes contactors and semiconductor contactors (solid state contactors).
Found what you need?
Document preview — SN/T 1431.6-2012
National Standard of the People's Republic of China
- Classification
- K30
Issued by: General Administration of Customs
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Energy efficiency requirements
- 4.1 Contactor energy efficiency rating
Foreword
SN/T 1431 "Importers and low-voltage electrical inspection procedures" is divided into six parts.
--- Part 1. General requirements;
--- Part 2. Household and similar circuit breakers for overcurrent protection;
--- Part 3. Household and similar residual current operated circuit breaker;
--- Part 4. Electromechanical contactors and motor starters;
--- Part 5. Low-voltage fuses;
--- Part 6. AC contactor energy efficiency.
This section SN/T 1431 Part 6.
This section drafted in accordance with GB/T 1.1-2009 given rules.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This section proposed and managed by the National Certification and Accreditation Administration Committee.
1 Scope
SN/T 1431 This section provides import and export of exchanges and contacts with energy efficiency requirements, sampling, testing and the results of determination.
This part of the direct drive rated frequency 50Hz, rated working voltage of 380V (400V), rated current of 6A ~ 630A Style, three-pole electric, AC contactor integral.
This section does not apply to additional energy-saving devices, for household and similar purposes contactors and semiconductor contactors (solid state contactors).
2 Normative references
GB 21518 AC contactor energy efficiency limit value and energy efficiency rating China energy efficiency labeling base style (NDRC Announcement 2004 No. 71)
3 Terms and Definitions
Terms and definitions defined in GB 21518 apply to this section.
4 Energy efficiency requirements
4.1 Contactor energy efficiency rating
Contactor energy efficiency rating is divided into three, the lowest level 1 holding power. Each grade contactor holding power shall be not greater than the requirements in Table 1.
Table 1 contactor (AC-3) energy efficiency rating
Rated operational current IE Holding power (V. A) Level 1 2 3 6<=IE<=12 0.5 5.0 9.0 12 \u003cIE<=22 0.5 5.1 9.5 twenty two \u003cIE<=32 0.5 8.3 14.0 32 \u003cIE<=40 0.5 11.4 19.0 40 \u003cIE<=63 0.5 31.2 57.0 63 \u003cIE<=100 1.0 36.6 61.0 100 \u003cIE<=160 1.0 51.3 85.5 160 \u003cIE<=250 1.0 91.2 152.0 250 \u003cIE<=400 1.0 150.0 250.0 400 \u003cIE<=630 1.0 150.0 250.0 Note. The same frame degree take maximum IE, for example. 40A ~ 65A for the same frame degree of contact, 65A should energy efficiency level assessment, namely
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 21518Minimum allowable values of energy efficiency and energy efficiency grades for AC contactors
Chinese energy efficiency labeling basic style NDRC Notice No. 71 of 2004
How to Download SN/T 1431.6-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 21518-2022 — Minimum allowable values of energy efficiency and energy efficiency grades for AC contactors
SN/T 1431.1-2011 — Rules for the inspection of low-voltage electrical apparatus for import and export. Part 1: General requirements
SN/T 1431.2-2011 — Rules for the inspection of low-voltage electrical apparatus for import and export. Part 2: Circuit-breakers for overcurrent protection for household and similar installations
Secure payment via Stripe
Payments accepted
SN/T 1431.6-2012
$149.00