GB 16916.1-2014[GB/T 16916.1-2014] Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB) -- Part 1: General rules (English PDF)
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB 16916.1-2014 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Mandatory
Issue date
May 6, 2014
Implementation date
June 29, 2015
Scope
GB 16916.1-2014 ([GB/T 16916.1-2014] Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB) -- Part 1: General rules) is available as an English-translated PDF.
GB 16916.1-2014 — This part of GB 16916 specifies the terms and definitions, technical requirements and tests of various types of RCCB.
Found what you need?
Document preview — GB 16916.1-2014
National Standard of the People's Republic of China
- ICS
- 29.120.50
- Classification
- K 31
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword...6
- 1 Scope...11
- 2 Normative references...13
- 3 Terms and definitions...14
- 3.1 Definition of flowing from the live parts into the earth current...14
- 3.2 Definition relating to the excitation of residual current circuit breaker...15
Foreword
The entire technical content of this part is mandatory.
GB 16916 "Residual current operated circuit-breakers without integral
overcurrent protection for household and similar uses (RCCB)" is divided into 3
parts.
- Part 1.General rules;
- Part 21.Applicability of the general rules to RCCB functionality
independence of supply voltage;
- Part 22.Applicability of the general rules to the RCCB functionally
dependent on supply voltage.
This part is part 1 of GB 16916.
This part was drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB 16916.1-2003 "Residual current operated circuit-
breakers without integral overcurrent protection for household and similar uses
(RCCB) - General rules".
As compared with GB 16916.1-2003, the main changes are as follows.
- In the Chapter 1 "Scope", EXTEND the AC rated frequency from 50 Hz or
60 Hz to 50 Hz, 60 Hz, or 50/60 Hz, that is, adding the frequency range
which can be applied to both 50 Hz and 60 Hz; meanwhile, in 5.3.7
"Standard frequency", ADD the standard frequency value 50/60 Hz;
- ADD 3.9 the definitions on insulation coordination;
- MODIFY the Table 1 and Table 2, in order to further define the limit values
of the A-type RCCB breaking time and not driving time;
- ADD the 5.3.13 the standard value of rated impulse withstand voltage (Uimp);
- In Chapter 6, MODIFY the marking of the rated frequency into. "rated
frequency; if RCCB is used for multiple frequencies (e.g. 50/60 Hz), it shall
mark it accordingly"; ADD that it may use the symbol to mark its application
for isolation";
- In 8.1.1, DEFINE the requirements for the set method of RCCB with multi-
level setting values;
- In 8.1.2, ADD the requirements that it shall provide the isolation distance as
necessary to satisfy the isolation function when the RCCB is at
disconnected position, and PROVIDE one or two indication devices to
indicate the devices of the main contact;
- MODIFY the contents of 8.1.3, 9.7.7, 9.20 and Appendix B on insulation
coordination. ADD the requirements and verification of isolation function; in
Table 5, INCREASE the electrical gap between the open contacts of the
RCCB of the rated working voltage 230/400 V, 230 V and 400 V from 3 mm
to 4 mm; ADD 9.7.7 the verification of impulse withstand voltage (across
the electrical gap and across solid insulation) and the leakage current
between open contacts;
- MODIFY 8.1.4.4 the description methods on the materials of the current
carrying parts. Originally it clearly indicates that the material of the current
carrying part is copper and other alloys, AND it is currently modified to
indicate that it is metal, making examples that the material is copper and
other alloys. It is defined that when using iron alloy or appropriate coating
of iron alloy, it shall use the anti-rust test to verify whether it comply with the
anti-corrosion requirements. Therefore, ADD the new clause "9.25 Anti-rust
test";
- MODIFY 9.5.1, specifying that the various types of conductors, hard
conductors (single core or twisted) and soft conductors shall be subjected
to the test, as well as the cross section range of the test conductors
corresponding to the conductor types; MODIFY the Table 12, defining the
tension force applied accordingly to the conductors of different cross
sections;
- ADD 9.7.7 "Verification of impulse withstand voltage (across the electrical
gap and across solid insulation) and the leakage current between open
contacts", which includes the test methods of using impulse withstand
voltage to verify the electrical gap, the leakage current between the open
contacts (suitable for isolation), the insulation between open contacts, and
the basic insulation withstand voltage capability. INCLUDE also the original
9.20 "verification of insulation impulse withstand voltage performance" into
this test clause; ADJUST accordingly the test voltage value;
- MODIFY 9.9.2.3 a) test methods for the suddenly appeared residual
sinusoidal AC current. MODIFY the method of measuring the breaking time
into firstly close the switch S2 and then close the power switch S1.The
time measured by the test method includes the time to supply power to the
RCCB, making the measurement time more reasonable;
- MODIFY 9.9.2.4 the test procedure for the residual current in the range of
5Ideltan to 500 A, from originally selecting 6 residual current values (5 A, 10 A,
20 A, 50 A, 100 A and 200 A) for test to arbitrarily selecting 2 residual current
values from the current range of 5 A ~ 200 A to conduct test, simplifying the
test procedures;
- In 9.11 the verification of RCCB working conditions under short-circuit
condition, MODIFY the test circuit and description method. COMBINE the
originally 5 short circuit tests respectively in single phase circuit, three
phase circuit, and three phase four wire circuit, respectively, into one short
circuit test diagram, and ADD an additional test circuit diagram and
impedance Z structure diagram for IT test; in 9.11.2.1 the general test
conditions, ADD item j). "oscillogram description", defining the methods on
how to determine the external voltage, the recovery voltage, and the
expected short-circuit current, etc., and ADD Figure 30 "Example of short
circuit test setting oscillogram";
- In 9.11.2.3, ADD a short circuit test to verify the applicability of RCCB in IT
systems;
- MODIFY 9.14 abnormal heat and flame test; MODIFY the number of
samples and application prohibition parts, the test is conducted on 3 test
specimens AND the glow-wire cannot be directly applied to the following
parts. terminals, arc chamber and electromagnetic trip part;
- In 9.17, DEFINE the test methods to verify the multi-phase power supply
requirements for the products as classified in 4.1.2.2;
- Further DEFINE the test methods to verify the correct action in 9.21.1.4
when the residual pulsating DC current is superimposed 0.006 A smooth
DC current;
- DELETE the original Appendix E "Test to verify the RCCB compliance with
electromagnetic compatibility (EMC) technical requirements, supplemental
test procedures, and test specimen quantity list", INCLUDE the
corresponding contents into the newly added clause 9.24 "Electromagnetic
compatibility" as well as the newly added EMC test procedures H, I and J
in the Table A.1, Table A.2 and Table A.3 in Appendix A, including the test
items, the number of test specimens and the qualification judgment number,
etc.; and ADD T2.6 the test items such as "the common mode conducted
disturbance below 150 kHz frequency range";
- ADD new Appendix. Specific requirements for RCCB with thread-less
terminals, Specific requirements for RCCB with flat fast connection
terminals, and Special requirements for RCCB with threaded connection
terminals connecting external untreated aluminum wires and the aluminum
threaded connection terminal to connect copper or aluminum conductors;
- RENUMBER the Appendix alphabetically.
This part, through the redrafting method, modifies and adopts the International
Electrotechnical Commission IEC 61008-1.2012 "Residual current operated
circuit-breakers without integral overcurrent protection for household and
similar uses (RCCB) - Part 1.General rules".
The main differences between this part and IEC 61008-1.2012 are as follows.
- In this part, as for the RCCB for which the Ideltan <= 0.03 A action function is
related to the power supply voltage AND which cannot be automatically
disconnected when the power supply voltage fails, RETAIN the technical
requirements that it can still act when the power supply voltage decreases
to 50 V as mentioned in GB 16916.1-2003.Therefore, ADD note 2 below
4.1.2.2, AND the test method shall follow 9.9.5.
- In paragraph 5 of 9.7.7.5 of IEC 61008-1.2012, it is mistakenly written as
follows. "Under conditions of 9.9.2.3, the RCCB shall trip when passing
through 1.25Ideltan current..."; it is corrected in this part as follows. "Under
conditions of 9.9.2.3a), the RCCB shall trip when passing through 1.25Ideltan
current...". This mistake also appears in 9.19.2.3, 9.22.1.3a), 9.22.1.5,
9.22.2 and 9.23, which shall be modified accordingly.
- In 9.11.2.1, MODIFY "SCPD (SEE 3.4.8)" into "SPCD (SEE 3.4.10);
MODIFY "impedance L" into "impedance Z".
- In Table A.1, MODIFY "9.1.5 Trip-free mechanism" into "9.15 Trip-free
mechanism".
- In Table I.1 (Table IE.1 of IEC 61008-1.2012), MODIFY "9.20 Verification of
electrical gap by impulse withstand voltage" into "9.7.7.2 Verification of
electrical gap by impulse withstand voltage"; ADD the descriptions. "it shall
also conduct test between each pole in order".
- As compared with IEC 61008-1.2012, in Table A.3 of Appendix A in this part,
ADD one group of 3 test specimens for the minimum In rating and maximum
Ideltan rating to the E test procedure; whilst DELETE one group of 3 test
specimens for the minimum In rating and maximum Ideltan rating from the G
test procedure. It is believed this is more reasonable, because it shall
respectively use the test specimens for maximum rating In and the minimum
rating In to conduct the short circuit test, whilst for the reliability test, it is
enough to conduct test against the test specimen of the maximum rating.
- RENUMBER the Appendix alphabetically.
This part specifies the terms and definitions, technical requirements and tests
of the various types of RCCBs. When used for a particular type of RCCB, this
part shall be used together with GB 16916.21-2008 "Residual current operated
circuit-breakers without integral overcurrent protection for household and
similar uses (RCCB) - Part 21.Applicability of the general rules to RCCB
functionality independence of supply voltage" and GB 16916.22-2008 Residual
current operated circuit-breakers without integral overcurrent protection for
household and similar uses (RCCB) - Part 22.Applicability of the general rules
to the RCCB functionally dependent on supply voltage".
This part was proposed by China Electrical Equipment Industry Association.
This part shall be under the jurisdiction of the National Low Voltage Electrical
Apparatus Standardization Technical Committee (SAC/TC 189).
The responsible drafting organizations of this part. Shanghai Electric Appliance
Research Institute, SEARI Electric Technology Co., Ltd.
The participating drafting organizations of this part. Zhejiang Zhengtai Electric
Appliance Co., Ltd., Schneider Electric (China) Investment Co., Ltd., Shanghai
Liangxin Electric Appliance Co., Ltd., Shanghai Electrical Equipment Testing
Institute, Suzhou Electric Appliance Research Institute Co., Ltd., Shanghai
Noark Electric Co., Ltd., Zhejiang Delixi Electric Co., Ltd., Foretech Electric
(Jiangsu) Co., Ltd., Sassin International Electric Shanghai Co., Ltd., JBANG
Electric Co., Ltd., Huatong Electromechanical Co., Ltd., Shanghai People
Enterprise Group Wenzhou Electric Co., Ltd., Legrand Low-voltage Electric
(Wuxi) Co., Ltd., TOLLEA Technology Group Co., Ltd., Yuyao Jiarong
Electronic Appliance Co., Ltd., Zhejiang Garcia Electrical Appliance Co., Ltd.
1 Scope
This part of GB 16916 specifies the terms and definitions, technical
requirements and tests of various types of RCCB.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) are applicable to this document.
GB 2099.1 Plugs and socket-outlets for household and similar purposes -
Part 1.General requirements (GB 2099.1-2008, IEC 60884-1.2006, MOD)
3 Terms and definitions
The following terms and definitions apply to this document.
The terms "voltage" and "current" used in this part are RMSs.
It refers to the current of pulsating wave form which assumes, in each period
of the rated power frequency, the value 0 or a value not exceeding DC 0.006
A, during one single interval of time, expressed in angular measure, of at
least 150°.
4 Classification
The RCCB is classified as follows.
5 RCCB characteristics
The rated operational voltage (hereinafter referred to as the rated voltage) of
the RCCB is the voltage value assigned by the manufacturer to which its
performance is referred.
The rated impulse withstand voltage of the RCCB shall be equal to or higher
than the standard value of the rated impulse withstand voltage as specified in
Table 3.
6 Marking and other product information
Each RCCB shall be marked in a durable manner with all or part of the following
(for small product) data.
For RCCBs operated by means of two buttons, the push-button designed for
the opening operation only shall be RED and/or be marked with the symbol "O".
Red shall not be used for any other push-button of the RCCB. If a push-button
is used for closing the contact AND is evidently identified as such, its depressed
position is sufficient indicate the closed position.
7 Standard conditions for operation in service and for installation
The RCCB complying with the requirements of this part shall be capable of
operating under the standard conditions as shown in Table 4.
8 Requirements for construction and operation
The moving contacts of all poles of multi-pole RCCB shall be so mechanically
coupled that all poles except for the switched neutral, if any, make and break
substantially together, whether operated manually or automatically.
If the cover is used as a guiding means for push-buttons, it shall not be possible
to remove the buttons from the outside of the RCCB.
9 Test
Unless otherwise specified, the RCCB is installed individually in accordance
with manufacturer's instructions and in free air, at an ambient temperature
between 20 °C and 25 °C, AND is protected against undue external heating or
cooling.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
GB 2099.1 · GB 2099.1-2008 · IEC 60884
Cited by
- GB/T 14048.2-2020Low-voltage switchgear and controlgear—Part 2: Circuit-breakers
- GB/Z 32513-2016General rules of reliability for low voltage apparatus
- JB/T 12762-2015Self-resetting overvoltage and undervoltage protectors
- GB 28527-2012Residual current devices with or without overcurrent protection for socket-outlets for household and similar uses
- GB 29303-2012[GB/T 29303-2012] Switched protective earth portable residual current devices for class I and battery powered vehicle applications
- GB/Z 22721-2008Guidance for the correct use of residual current-operated protective devices (RCDs) for household and similar use
How to Download GB 16916.1-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 11557-2026 — Provisions for protecting drivers from injury by the steering mechanism of motor vehicles
GB 12021.4-2026 — Maximum allowable values of the energy consumption, water consumption and grades for electric washing machines and washer-dryers
Secure payment via Stripe
Payments accepted
GB 16916.1-2014
$400.00