Valid

GB 16916.21-2008Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB) -- Part 21: Applicability of the general rules to RCCB functionally independent of line voltage (English PDF)

家用和类似用途的不带过电流保护的剩余电流动作断路器(RCCB) 第21部分:一般规则对动作功能与电源电压无关的RCCB的适用性

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for GB 16916.21-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Mandatory

Issue date

June 19, 2008

Implementation date

June 1, 2009

Scope

GB 16916.21-2008 is the English-translated version of 家用和类似用途的不带过电流保护的剩余电流动作断路器(RCCB) 第21部分:一般规则对动作功能与电源电压无关的RCCB的适用性.

GB 16916.21-2008 — Except for the following modifications, Part 1 applies. Instead of the first paragraph with the following.

The operation of this section applicable to the exchange rated voltage not exceeding 440V, rated current not exceeding 125A is mainly used for protection against electric shock Function independent of the supply voltage for household and similar uses overcurrent protection for residual current operated circuit breaker (RCCB).

Found what you need?

Document preview — GB 16916.21-2008

National Standard of the People's Republic of China

ICS
29.120.50
Classification
K 31
Replacing
GB 16916.21-1997

Issued by: Standardization Administration of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 5 RCCB features
  • 6 Logos and other product data
  • 8 Structure and operating requirements
  • 9 Test

Foreword

All technical content in this section is mandatory.

GB 16916 "Household and similar uses overcurrent protection for residual current operated circuit breaker (RCCB)" divided into the following section.

--- Part 1. General rules;

--- Part 21. General rules for the operation of the functions independent of line voltage RCCB applicability;

--- Part 22. General rules for the operation of the function and line voltage RCCB applicability.

This section GB Part of 2,116,916.

This section identical with IEC 61008-2-1:1990 "Household and similar uses overcurrent protection for residual current operated circuit breaker (RCCB) - Part 2.1. General rules for the operation of the functions independent of line voltage RCCB applicability. " this section should be used and GB 16916.1-2003 "household and similar purposes without overcurrent protection RCBO (RCCB) - Part 1. General rules "together.

This Part replaces GB 16916.21-1997, the main difference between this part and GB 16916.21-1997 follows.

--- The whole standard "line voltage" to "supply voltage";

--- Chapter 6 "n) item" to "m) item";

--- The "9.11.2.1a) the last two" to "9.11.2.1a) last paragraph." this part is proposed by the China Electrical Equipment Industrial Association.

The low-voltage electrical part by the National Standardization Technical Committee (SAC/TC189) centralized.

This section is responsible for drafting unit. Shanghai Electrical Apparatus Research Institute (Group) Co., Ltd.

Participated in the drafting of this section. Schneider Electric (China) Investment Co., Ltd.

Introduction

Part of GB 2116916 (ie GB 16916.21) is the corresponding provisions of Part 1 (ie GB 16916.1) supplement or repair to change, to accommodate motor function independent of supply voltage of the RCCB.

GB 16916.21-2008/IEC 61008-2-1:1990 Household and similar purposes without overcurrent protection Residual current operated circuit breaker (RCCB) Part 21. General rules for the operation of the function Applicability of the power supply voltage independent RCCB

1 Scope

Except for the following modifications, Part 1 applies.

Instead of the first paragraph with the following.

The operation of this section applicable to the exchange rated voltage not exceeding 440V, rated current not exceeding 125A is mainly used for protection against electric shock Function independent of the supply voltage for household and similar uses overcurrent protection for residual current operated circuit breaker (RCCB).

2 Normative references

The following documents contain provisions which, through reference in this Part of GB 16916, constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

Part 1 of this clause apply.

3 Terms and Definitions

In addition to Part 1 of 3.3.5,3.4.10 NA, the other are applicable.

Category 4

In addition to 4.1.2, Part 1 provisions apply.

5 RCCB features

Except for the last two lines of 5.1 is not applicable, the provisions of Part 1 applies.

6 Logos and other product data

Apart) m NA item, the Part 1 provisions apply.

7 and the standard conditions of installation Part 1 provisions apply.

8 Structure and operating requirements

In addition to 8.12 NA, the provisions of Part 1 applies.

9 Test

In addition to the following, in part 1 of this clause apply.

9.1.1 in Table 7, line 15 (about 9.17 Test) Not applicable.

GB 16916.21-2008/IEC 61008-2-1:1990

9.7.4 Note 3 does not apply.

9.9.5 Not applicable.

9.11.2.1a) last paragraph and i) the last paragraph does not apply.

9.17 Not applicable.

Last paragraph 9.18.1 and 9.18.2 do not apply.

Part 1 would apply.

appendix

In addition to Appendix A, Table A. 1 in terms of "working conditions 9.17 supply voltage fault" (test sequences D.1) NA and Annex IB the last two symbols NA, the other contents of the first section of the appendix apply.

GB 16916.21-2008/IEC 61008-2-1:1990

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

Referenced standards

Normative references

GB 16916

How to Download GB 16916.21-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 16916.21-2008

$65.00