SN/T 1431.3-2011Rules for the inspection of low-voltage electrical apparatus for import and export. Part 3: Residual current cooperated circuit-breakers for household and similar uses (English PDF)
进出口低压电器检验规程 第3部分:家用和类似用途剩余电流动作断路器
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for SN/T 1431.3-2011 in 30 minutes.
Issued by
General Administration of Customs
Level / Type
National · Recommended
Issue date
September 9, 2011
Implementation date
April 1, 2012
Scope
SN/T 1431.3-2011 is the English-translated version of 进出口低压电器检验规程 第3部分:家用和类似用途剩余电流动作断路器.
SN/T 1431.3-2011 — This section provides a sample import and export of household and similar residual current operated circuit breaker, test results and determination.
This section applies to AC 50Hz (or 60Hz), voltage does not exceed 440V, rated current not exceeding 125A household or similar purposes Inspection of residual current operated circuit breaker.
This section does not apply to product testing. --- Using battery RCCB; --- For motor protection RCBO; --- Setting current value by the user in the use of self-regulation of RCBO.
Found what you need?
Document preview — SN/T 1431.3-2011
National Standard of the People's Republic of China
- ICS
- 29.120.30
- Classification
- L 24
- Replacing
- SN/T 0996-2001
Issued by: General Administration of Customs
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
Foreword
SN/T 1431 "Importers and low-voltage electrical inspection procedures" series of standards is divided into five parts.
--- Part 1. General requirements;
--- Part 2. Household and similar circuit breakers for overcurrent protection;
--- Part 3. Household and similar residual current operated circuit breaker;
--- Part 4. Electromechanical contactors and motor starters;
--- Part 5. low voltage fuses.
This is Part 3 SN/T 1431 "Importers and low-voltage electrical inspection procedures" series of standards.
This section based on GB/T 1.1-2009 write drafted.
Some of this section may involve patents, this part of the release mechanism does not assume the responsibility to identify these patents.
The partial replacement of SN/T 0996-2001, compared with the SN/T 0996-2001 The main changes are as follows.
--- Examine the contents of the deleted original packaging procedures, shape and installation manual testing, electromagnetic compatibility test, delete, and modify some of the Visual inspection contents;
--- Increasing the consistency test project, assembly quality inspection;
--- Modify the flag checking the contents of the original dielectric strength test procedure to test dielectric properties, and to increase the inspection auxiliary circuit Seeking original statutes overcurrent protection characteristics test (if applicable) to modify the overcurrent tripping characteristic and increase its requirements in Table 3 Detailed description of the operating characteristics of the original statutes to Residual Current Operating Characteristic (no-load);
--- Table 2. visual inspection of the surface of the product failed to Category B, over-current operating characteristics of substandard classification according to different projects Divided into Class A and Class B;
--- Increased content inspection and supervision mode and test mode.
This section proposed and managed by the National Certification and Accreditation Administration Committee.
This section drafted by. People's Republic of China Zhejiang Exit Inspection and Quarantine.
Introduction
"Importers and low-voltage electrical inspection of" low-voltage electrical products import and export inspection work basis, import and export of low-voltage electrical products Inspection play a guiding and regulating.
With China's accession to the World Trade Organization (WTO) and the revised "People's Republic of China Import and Export Commodity Inspection Law" Import and Export Commodity Inspection Test mode has undergone great change, to adapt to changes in the situation and to meet the actual needs of inspection and quarantine work, Inspection and Quarantine of the competent Inspection and quarantine departments to establish a standard system.
This part belongs to the standard system of inspection and quarantine fourth floor --- personality standard that specifies the import and export of household and similar residual current operated Breaker inspection requirements.
Low-voltage electrical inspection of import and export Part 3. Household and similar residual current operated breaker
1 Scope
This section provides a sample import and export of household and similar residual current operated circuit breaker, test results and determination.
This section applies to AC 50Hz (or 60Hz), voltage does not exceed 440V, rated current not exceeding 125A household or similar purposes Inspection of residual current operated circuit breaker.
This section does not apply to product testing.
--- Using battery RCCB;
--- For motor protection RCBO;
--- Setting current value by the user in the use of self-regulation of RCBO.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2828.1-2003 Sampling procedures for inspection - Part 1. Press to accept the quality limit (AQL) retrieval batch test sample Programme (ISO 2859-1:1999, IDT) GB/T 2900.18-2008 Electrotechnical term low-voltage electrical (RCCB) Part 1 GB 16916.1-2003 household and similar uses overcurrent protection for residual current operated circuit breaker Score. General rules (IEC 61008-1:1996, MOD) GB 16917.1-2003 household and similar uses overcurrent protection for residual current operated circuit breaker (RCBO) (IEC 61009-1:1996, MOD) the basic provisions of SN/T 0002 Electromechanical Import and Export Commodity Inspection procedures prepared
3 Terms and Definitions
GB/T 2828.1-2003, GB/T 2900.18-2008, GB 16916.1-2003, GB 16917.1-2003 and SN/T 0002 Defining the following terms and definitions apply to this document.
Sampling mode modeofsamplinginspection According to the mandatory requirements of national technical specifications, batch import and export commodities or pumping grant implementation sampling, testing and inspection of conformity assessment activities.
Type Test mode modeoftypetest According to a predetermined cycle based on the mandatory requirements of national technical specifications type testing, according to on-site inspection requirements for product pumping batch inspection Inspection, supervision and implementation of the conformity assessment activities of the enterprise quality management system.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2828.1-2003Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
- GB/T 2900.18-2008Electrotechnical terminology - Low voltage apparatus
- GB 16916.1-2003[GB/T 16916.1-2014] Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB) -- Part 1: General rules
- GB 16917.1-2003Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) -- Part 1: General rules
- SN/T 0002General rules for drafting of regulations for inspection of import and export mechanical and electrical commodity
ISO 2859 · IEC 61008 · IEC 61009
How to Download SN/T 1431.3-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2900.18-2008 — Electrotechnical terminology - Low voltage apparatus
SN/T 0002.1-2012 — General rules for drafting of regulations for inspection of import and export mechanical and electrical commodity
SN/T 0002.2-2012 — General stipulation for drafting of standards on inspection method of mechanical and electrical commodity for import and export
Secure payment via Stripe
Payments accepted
SN/T 1431.3-2011