Valid

GA/T 841-2021General technical requirements for trace narcotics/explosives detectors based on ion mobility spectrometry (English PDF)

基于离子迁移谱技术的痕量毒品炸药探测仪通用技术要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (14 pages)

Need quotation for your management?

Get a formal quotation for GA/T 841-2021 in 30 minutes.

Issued by

Ministry of Public Security

Level / Type

National · Recommended

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

GA/T 841-2021 is the English-translated version of 基于离子迁移谱技术的痕量毒品炸药探测仪通用技术要求.

GA/T 841-2021 — This document specifies the requirements for trace drug detectors, trace explosive detectors, trace drugs and explosive detectors based on ion mobility spectrometry: Requirements for classification, technical requirements, marking, packaging, transportation and storage, describe test methods, and establish inspection rules: This document applies to trace drug detectors, trace explosives detectors, trace drugs and explosives based on ion mobility spectrometry with swab sampling: Design, manufacture and inspection of drug detectors:

Found what you need?

Document preview — GA/T 841-2021

National Standard of the People's Republic of China

Classification
A 91

Issued by: Ministry of Public Security

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Category
  • 5 Technical requirements
  • 6 Test method
  • 7 Inspection rules
  • 8 Marking, packaging, transportation and storage

Foreword

This document is drafted in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents":

This document replaces GA/T 841-2009 "General technical requirements for trace drug/explosive detectors based on ion mobility spectrometry", and Compared with GA/T 841-2009, in addition to structural adjustment and editorial changes, the main technical changes are as follows:

a) Modified terms, added detection limit, blank test, self-cleaning time, characteristic database (see 3.5, 3:7, 3:9, 3:11), deleted Ion mobility spectrometer, trace drug/explosive detector, inhalation sampling, cold start (see 3.2, 3:3, 3:4, 3:6 of the:2009 edition), revised Changed the swab sampling and detection rate (see 3.2, 3:3, 3:5 and 3:9 of the:2009 edition);

b) Modified the appearance requirements [see 5.1, 5:1a), b) of the:2009 edition];

c) Added identification requirements (see 5.2);

d) Added quality requirements (see 5.3);

e) Modified the software function (see 5.4, 5:2:3 of the:2009 edition);

f) Added self-test requirements (see 5.5, 5:2:4 of the:2009 edition);

g) revised storage capacity requirements [see 5.6, 5:2:3d) of the:2009 edition];

h) revised data interface requirements (see 5.7, 5:2:4 of the:2009 edition);

i) Modified the alarm prompt requirements (see 5.8, 5:2:5 of the:2009 edition);

j) Added school hours requirements (see 5.9);

k) delete the sampling method requirement (5:2:2 of the:2009 edition);

l) Modify the requirements for the types of detectable substances (see 5.11:2, 5:3:2 of the:2009 edition);

m) Modified the detection limit requirements (see 5.11:3, 5:3:4 of the:2009 edition);

n) Added self-cleaning time requirement (see 5.11:5);

o) Modify the overload recovery time requirements (see 5.11:6, 5:3:6 of the:2009 edition);

p) revised power requirements (see 5.12, 5:2:1 of the:2009 edition);

q) Modified the electrical safety requirements (see 5.13, 5:6:2 of the:2009 edition);

r) Modified radiation safety requirements (see 5.14, 5:6:1 and 5:5:2 of the:2009 edition);

s) Modified electromagnetic compatibility requirements (see 5.15, 5:5 of the:2009 edition);

t) Modified the requirements for environmental adaptability (see 5.16, 5:4 of the:2009 edition);

u) Modified the test environment requirements (see 6.1:1, 6:1 of the:2009 edition);

v) The configuration method of the detection solution was deleted (see 6.2:3 of the:2009 edition);

w) Revised the sample requirements for drugs and explosives (see 6.1:2, 6:2:1 of the:2009 edition); added the requirements for detector samples (see 6.1:3);

x) Modified the basic detection performance verification test method (see 6.2, 6:2:6 of the:2009 edition); test methods for the types of detectable substances (See 6.13:4, 6:5:2 of the:2009 edition); Test methods for environmental suitability (see 6.18, 6:6 of the:2009 edition):

Please note that some content of this document may involve patents: The issuing agency of this document assumes no responsibility for identifying patents:

1 Scope

This document specifies the requirements for trace drug detectors, trace explosive detectors, trace drugs and explosive detectors based on ion mobility spectrometry:

Requirements for classification, technical requirements, marking, packaging, transportation and storage, describe test methods, and establish inspection rules:

This document applies to trace drug detectors, trace explosives detectors, trace drugs and explosives based on ion mobility spectrometry with swab sampling:

Design, manufacture and inspection of drug detectors:

2 Normative references

The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document:

GB/T 191 Graphical signs of packaging, storage and transportation GB/T 2423.1-2008 Environmental Testing of Electrical and Electronic Products Part 2: Test Methods Test A: Low Temperature GB/T 15211-2013 Environmental adaptability requirements and test methods for safety precaution and alarm equipment GB 16796-2009 Safety requirements and test methods for safety precaution and alarm equipment GB/T 17626.2-2018 Electromagnetic Compatibility Test and Measurement Technology Electrostatic Discharge Immunity Test GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology Radio frequency electromagnetic field radiation immunity test GB/T 17626.4-2018 Electromagnetic Compatibility Test and Measurement Technology Electrical Fast Transient Burst Immunity Test GB/T 17626.5-2019 Electromagnetic Compatibility Test and Measurement Technology Surge (Shock) Immunity Test

3 Terms and Definitions

The following terms and definitions apply to this document:

ion mobility spectrometry Using the difference in the mobility of gas-phase ions formed by the ionization reaction of substances in an electric field to achieve trace analysis for the identification of the tested sample Technology:

wipe sampling wipesamplecolection the method of wiping the surface of the test object with the sampling carrier to collect the sample for analysis:

Detection rate probabilityofdetection the probability that the detector can correctly alarm when detecting explosives/drugs:

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

Referenced standards

How to Download GA/T 841-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GA/T 841-2021

$240.00