YY/T 1766.2-2021Image quality evaluation methods for computed tomography system - Part 2: Low contrast resolution evaluation (English PDF)

X射线计算机体层摄影设备图像质量评价方法 第2部分:低对比度分辨率评价

Preview PDF

This is a limited preview

Buy now to download the full PDF (20 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1766.2-2021 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

March 9, 2021

Implementation date

April 1, 2022

Scope

YY/T 1766.2-2021 is the English-translated version of X射线计算机体层摄影设备图像质量评价方法 第2部分:低对比度分辨率评价.

YY/T 1766.2-2021 is the Chinese pharmaceutical industry standard that gives the method for evaluating the low-contrast resolution of the images produced by an X-ray computed tomography scanner, that is the smallest object of slight density difference that can still be distinguished.

It is the second part of the YY/T 1766 series and sets the phantom, the scanning and reconstruction conditions, the reading of the result and the way it is reported.

It applies to whole body and special purpose CT equipment, including scanners used to provide image data for radiotherapy planning, and not to dental CT, nor to angiographic and mobile C-arm equipment with three-dimensional imaging. Issued on 9 March 2021, it has applied since 1 April 2022.

Found what you need?

Document preview — YY/T 1766.2-2021

National Standard of the People's Republic of China

Classification
C 43

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Quantitative evaluation of low contrast resolution of CT scanning device
  • 4.1 Test overview
  • 4.2 Test method
  • 4.3 Expression of results
  • 5 Objective contrast evaluation of low-contrast resolution when using reduced-dose image reconstruction technology
  • 5.1 Test overview
  • 5.2 Test method
  • 5.3 Expression of results
  • Appendix A (informative appendix) Overview of task-based model observer evaluation
  • Appendix B (informative appendix) Model observers and channelization methods used in this standard
  • Appendix C (informative appendix) Quantitative evaluation based on manual observer
  • Appendix D (Informative Appendix) Operating Conditions for Evaluation of Low Contrast Resolution
  • Appendix E (informative appendix) Supplementary explanation of the statistical analysis of the recognition task. ROC, AUC and accuracy
  • Reference

Foreword

YY/T 1766 "X-ray computed tomography equipment image quality evaluation method" is divided into the following two parts.

---Part 1: Modulation transfer function evaluation;

---Part 2: Evaluation of low-contrast resolution. This part is part 2 of YY/T 1766.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

Please note that certain contents of this document may involve patents. The issuing agency of this document is not responsible for identifying these patents.

Introduction

The low-contrast resolution of CT is an important indicator of the image performance of CT scanning devices, and it also reflects the image quality and dose of CT scanning devices. Horizontal relationship.

At present, the absolute evaluation of the low-contrast resolution of CT scanning devices is mainly done through visual evaluation.

The influence of many factors. Due to the significant difference in low-contrast resolution at different doses, the expression of low-contrast resolution evaluation results is also A standardized and standardized form is needed.

On the other hand, with reduced dose CT image reconstruction technology (such as iterative reconstruction technology, etc.), more and more CT products are applied How to effectively evaluate the comparability of low-contrast resolution while reducing the dose is also an important aspect of image quality evaluation.

The method based on manual (expert) visual evaluation is often time-consuming and does not have broad application significance. Based on the objective comparative evaluation of the model observer Based on the research foundation in recent years, the price has also been gradually introduced into CT image quality evaluation.

Based on the above status, this standard provides the low-contrast resolution for CT scanning devices and the use of reduced-dose image reconstruction technology Afterwards, the achievable dose reduction level is given a standardized evaluation method.

The implementation of this method standard will surely unify and standardize the evaluation of low-contrast resolution in the CT industry.

1 Scope

This part of YY/T 1766 specifies the evaluation method of low-contrast resolution of CT scanning device images.

This part is applicable to whole body and special X-ray computed tomography equipment (hereinafter referred to as CT scanning device), including radiotherapy CT scanning devices that plan to provide image data, but do not include oral CT scanning devices or angiography and mobile imaging with three-dimensional imaging capabilities. Moving C-arm equipment.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 10149-1988 Medical X-ray equipment terms and symbols

3 Terms and definitions

The following terms and definitions defined in GB/T 10149-1988 apply to this document.

3.1 Lowcontrastresolution

The lowest contrast detail that can be distinguished from a uniform background for an object of a prescribed shape and size. [GB/T 19042.5-2006.3.11]

Note. Low contrast resolution is also expressed as lowcontrastdetectability (LCD).

3.2 Region of interest; ROI

Part of the image of particular interest drawn on the image at a certain moment. [GB/T 19042.5-2006.3.15]

3.3 CT operating conditions CTconditionsofoperation

All optional parameters that dominate the operation of the CT scanning device.

Note 1.Including, for example, the nominal body slice thickness, pitch coefficient, filtration, peak X-ray tube voltage, and X-ray tube current and loading time, or current time Between product.

Note 2.Some CT operating conditions may change during the exposure process.

Note 3.CT operating conditions include the parameters generated by the system according to the parameters selected by the user. [IEC 60601-2-44:2009/AMD2.2016, definition.201.3.202]

3.4 Protocol unit

A specific set of CT operating conditions necessary to perform a scan.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 1766.2-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
20 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1766.2-2021

$390.00