YY/T 1766.1-2021Image quality evaluation methods for computed tomography system - Part 1: Modulation transfer function evaluation (English PDF)
X射线计算机体层摄影设备图像质量评价方法 第1部分: 调制传递函数评价
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1766.1-2021 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
March 9, 2021
Implementation date
April 1, 2022
Scope
YY/T 1766.1-2021 is the English-translated version of X射线计算机体层摄影设备图像质量评价方法 第1部分: 调制传递函数评价.
YY/T 1766.1-2021 is the Chinese pharmaceutical industry standard that gives the method for evaluating the spatial resolution of an X-ray computed tomography scanner through its modulation transfer function.
It is the first part of the YY/T 1766 series on CT image quality and sets out the phantom and the scanning conditions, how the edge or wire response is measured and transformed into the MTF, and how the result is stated, so that the resolution declared for different scanners is obtained in the same way.
It applies to whole body and special purpose CT equipment. Issued on 9 March 2021, it has applied since 1 April 2022.
Found what you need?
Document preview — YY/T 1766.1-2021
National Standard of the People's Republic of China
- Classification
- C 43
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
Foreword
YY/T 1766 "X-ray computer tomography equipment image quality evaluation method" is divided into two parts.
---Part 1: Modulation transfer function evaluation;
---Part 2: Evaluation of low-contrast resolution. This part is part 1 of YY/T 1766.
This section was drafted in accordance with the rules given in GB/T 1.1-2009.
Introduction
Spatial resolution, also known as high contrast resolution, is an important indicator of the image performance of CT scanning devices.
Historically, the test of this indicator was mainly through the subjective test method of visually inspecting high-contrast line pairs or small holes. Subjective assessment methods are limited by The observation ability of the human eye cannot accurately describe CT performance. Therefore, the MTF-frequency domain curve objective evaluation program is used by major manufacturers to make progress. Perform CT evaluation.
The test method of the existing standard (such as YY/T 0310) spatial resolution test item is described as. Use the MTF method to measure the spatial resolution However, there is no detailed and accurate description of the MTF test method at present. Allows different manufacturers in the industry to evaluate spatial resolution test items There are differences in current practices, and the spatial resolution test results obtained by various manufacturers are less comparable.
Based on the above status, this section gives the test methods and evaluations of the spatial resolution of the CT scanning device, using the modulation transfer function. The price standard is proposed for the purpose.
The implementation of this method standard will surely make the evaluation of spatial resolution in the CT industry unified and standardized.
1 Scope
This part of YY/T 1766 is applicable to whole body and special X-ray computed tomography equipment (hereinafter referred to as CT scanning device).
This section specifies the modulation transfer function (MTF) evaluation method of the spatial resolution of X-ray CT scanning devices.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated reference documents, the latest version (including all amendments) is applicable to this document.
GB/T 10149-1988 Medical X-ray equipment terms and symbols
3 Terms and definitions
The following terms and definitions defined in GB/T 10149-1988 apply to this document.
3.1 Spatialresolution
When the difference between the attenuation value of the object and the background is much larger than the noise, the computer tomography equipment can distinguish the difference of different objects in the displayed image. ability.
Note 1.Usually the difference of the attenuation coefficient between the object and the background causes the difference of hundreds of HU units in the corresponding CT value to be considered as large enough.
Note 2.High contrast resolution is another term for spatial resolution. [GB/T 19042.5-2006, definition 3.17]
3.2 Point spread function pointspread function; PSF
In a specific plane or axis direction, the target pixel value distribution on the image formed by the imaging system for a sufficiently small target.
3.3 Modulation transfer function; MTF
The modulus of the system's point spread function after Fourier transform.
3.4 Region of interest; ROI
Part of the image of particular interest drawn on the image at a certain moment. [GB/T 19042.5-2006, definition 3.15]
3.5 CT operating conditions CTconditionsofoperation
All optional parameters that dominate the operation of the CT scanning device.
Note 1.Including, for example, the nominal body slice thickness, pitch coefficient, filtration, peak X-ray tube voltage, and X-ray tube current and loading time, or current time Between product.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 1766.1-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10149-1988 — Terminology and symbol for medical X-ray equipment
YY/T 1766.2-2021 — Image quality evaluation methods for computed tomography system - Part 2: Low contrast resolution evaluation
YY/T 1766.3-2023 — Image quality evaluation methods for X-ray computed tomography equipment - Part 3: Performance evaluation of dual-energy imaging and spectral applications
Secure payment via Stripe
Payments accepted
YY/T 1766.1-2021
$150.00