GB/T 29067-2012Non-destructive testing - Test method for measuring industrial computed tomography (CT) image (English PDF)
无损检测 工业计算机层析成像(CT)图像测量方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 29067-2012 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 31, 2012
Implementation date
October 1, 2013
Scope
GB/T 29067-2012 is the English-translated version of 无损检测 工业计算机层析成像(CT)图像测量方法.
GB/T 29067-2012 is the Chinese standard "Non-destructive testing - Test method for measuring industrial computed tomography (CT) image".
Its scope clause reads: This standard specifies the (CT) system and the size of the image density measurement calibration measurement calibration for non-destructive testing of industrial computer tomography Method, and a method for measuring the object to be measured from the CT image material density and size.
The standard test for measuring the density of each part of the interior of the body (including the measured internal body composed of different materials in each part of the secret Degrees) and the measured object and outside the structure (especially a closed cavity) geometry. Its clauses include terms and definitions; basic.
Found what you need?
Document preview — GB/T 29067-2012
National Standard of the People's Republic of China
- ICS
- 19.100
- Classification
- J 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 BASIC
1 Scope
This standard specifies the (CT) system and the size of the image density measurement calibration measurement calibration for non-destructive testing of industrial computer tomography
Method, and a method for measuring the object to be measured from the CT image material density and size.
The standard test for measuring the density of each part of the interior of the body (including the measured internal body composed of different materials in each part of the secret
Degrees) and the measured object and outside the structure (especially a closed cavity) geometry.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 12604.2 Terminology for nondestructive testing radiographic testing
3 Terms and Definitions
Terms and definitions GB/T 12604.2 defined apply to this document.
4 BASIC
4.1 Testing Equipment Requirements
It requires the relevant testing equipment (including industrial CT image processing equipment and related software), and requires customers and suppliers in the relevant
We agreed terms.
4.2 avoid the influence of image artifacts on the density measurement
Density measurement method requires. CT density changes reflect real changes in the density of the object instead of image artifacts. Since the detector
Response inconsistent ray scattering beam hardening and other reasons, CT images may exhibit some degree of artifacts and artifacts are often mistaken
Density variations. To ensure the effectiveness of this method of density measurement, industrial equipment manufacturers to respond ray CT projection data is corrected to minimize
Reducing CT image artifacts. In actual testing, you should try to avoid the area affected by artifacts Density measurements.
4.3 avoid the influence of image artifacts on the size measurement
Size measurement method requires. the measured area of the object corresponding to the CT image should have a relatively steep edges. Since the detector ring
Should not, ray scattering beam hardening and other reasons, CT images may exhibit some degree of artifacts, in addition to the straight edge of the object
Edge strip may cause artifacts. To ensure the effectiveness of the method of measuring the size of industrial CT equipment manufacturers respond ray projection data into
Line correction to minimize the CT image artifacts. In actual testing, you should try to avoid the area affected by the dimensional artifacts measuring.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 29067-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 29067-2012
$155.00