YY/T 1766.3-2023Image quality evaluation methods for X-ray computed tomography equipment - Part 3: Performance evaluation of dual-energy imaging and spectral applications (English PDF)

X射线计算机体层摄影设备图像质量评价方法 第3部分:双能量成像与能谱应用性能评价

Preview PDF

This is a limited preview

Buy now to download the full PDF (34 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1766.3-2023 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

June 20, 2023

Implementation date

January 1, 2025

Scope

YY/T 1766.3-2023 is the English-translated version of X射线计算机体层摄影设备图像质量评价方法 第3部分:双能量成像与能谱应用性能评价.

YY/T 1766.3-2023 is the Chinese standard "Image quality evaluation methods for X-ray computed tomography equipment - Part 3: Performance evaluation of dual-energy imaging and spectral applications".

Its scope clause reads: This document specifies the dual-energy imaging and energy spectrum applications of X-ray computed tomography equipment (hereinafter referred to as CT scanning equipment) Performance evaluation methods.

This document applies to whole-body and dedicated CT scanning devices, including CT scanning devices that provide image data for radiotherapy planning, but does not include Including oral CT scanning devices or angiography and mobile C-arm equipment with three-dimensional imaging capabilities. Its clauses include normative reference documents; terms and definitions.

Found what you need?

Document preview — YY/T 1766.3-2023

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C43

Issued by: National Medical Products Administration

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative reference documents
  • 3 Terms and Definitions
  • 4 Typical imaging conditions of CT dual-energy imaging
  • 5 Dose level evaluation method of CT dual-energy imaging
  • 5.1 Test device
  • 5.2 Test conditions
  • 5.3 Test principle
  • 5.4 Test method
  • 5.5 Result expression
  • 6 Conventional image performance evaluation methods for CT dual-energy imaging
  • 6.1 Noise amplitude, average CT value and uniformity
  • 6.2 XY plane modulation transfer function (MTF)
  • 6.3 Z-axis MTF
  • 6.4 Reconstructing slice thickness
  • 6.5 Low contrast resolution
  • 7 Energy spectrum image performance evaluation method for CT dual-energy imaging
  • 7.1 Evaluation of material separation performance
  • 7.2 Quantitative performance evaluation of substances
  • 8 Performance evaluation methods applicable to CT dual-energy imaging and energy spectrum applications
  • 8.1 Overview
  • 8.2 CT dual-energy imaging that provides high-energy images and low-energy images
  • 8.3 Providing CT dual-energy imaging for routine diagnostic images
  • 8.4 CT dual-energy imaging that provides CT energy spectrum images
  • 8.5 Post-processing software for energy spectrum applications
  • 8.6 Evaluation methods applicable to CT dual-energy imaging and energy spectrum applications
  • Appendix A (informative) Implementation methods of CT dual-energy imaging technology
  • Appendix B (informative) Physical properties of reference materials and X-ray interaction
  • Appendix C (informative) Image type generation principles and evaluation examples of common CT dual-energy imaging
  • Appendix D (informative) Relevant standards and research materials

1 Scope

This document specifies the dual-energy imaging and energy spectrum applications of X-ray computed tomography equipment (hereinafter referred to as CT scanning equipment)

Performance evaluation methods.

This document applies to whole-body and dedicated CT scanning devices, including CT scanning devices that provide image data for radiotherapy planning, but does not include

Including oral CT scanning devices or angiography and mobile C-arm equipment with three-dimensional imaging capabilities.

2 Normative reference documents

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations

For referenced documents without dates, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document.

document.

GB 9706.244-2020 Medical electrical equipment Part 2-44.Basic safety and basic performance of X-ray computed tomography equipment

Special requirements

GB/T 10149 Medical X-ray equipment terms and symbols

GB/T 19042.5-2022 Evaluation and routine testing of medical imaging departments Part 3-5.X-ray computed tomography equipment

Image performance acceptance test and stability test

YY/T 1766.1-2021 X-ray computed tomography equipment image quality evaluation method Part 1.Modulation transfer function evaluation

YY/T 1766.2-2021 Image quality evaluation method for X-ray computed tomography equipment Part 2.Low contrast resolution evaluate

3 Terms and definitions

The following terms and definitions as defined in GB/T 10149, GB 9706.244-2020, GB/T 19042.5-2022 apply to this document.

3.1

An imaging method that uses a CT scanning device to obtain data corresponding to a single energy spectrum for image reconstruction and processing.

Note 1.The “energy spectrum” here refers to the energy distribution in the traditional physics sense.

Note 2.Usually based on a single tube voltage, single filtering, energy integrating detector.

Note 3.Imaging with conventional CT scanning devices is usually single-energy imaging.

3.2 CT dual energy imagingdualenergyCTimaging

Use a CT scanning device to obtain data corresponding to two energy spectra in a dual-energy imaging process for imaging reconstruction and processing.

Way.

Note 1.The “energy spectrum” here refers to the energy distribution in the traditional physics sense.

Note 2.Different energy spectrum data can be generated and acquired through technology based on ray sources, filtering, and detectors. The current technology implementation method of CT dual-energy imaging […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 34 pages — is available in the English PDF.

Referenced standards

How to Download YY/T 1766.3-2023

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
34 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1766.3-2023

$485.00