YY/T 1649.1-2019Test method for interactions of medical devices with platelet - Part 1: In vitro platelet count assay (English PDF)
医疗器械与血小板相互作用试验 第1部分:体外血小板计数法
This is a limited preview
Buy now to download the full PDF (23 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1649.1-2019 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
May 31, 2019
Implementation date
June 1, 2020
Scope
YY/T 1649.1-2019 is the English-translated version of 医疗器械与血小板相互作用试验 第1部分:体外血小板计数法.
YY/T 1649.1-2019 is the Chinese pharmaceutical industry standard that gives the platelet count method for studying how a medical device or material interacts with platelets in vitro, as part of the assessment of blood compatibility.
Blood is exposed to the device or material and the fall in platelet count, together with the markers of activation, shows how far platelets adhere to the surface and are set off by it.
The test system is established for human blood; where animal blood is used, its suitability has to be demonstrated. It is the first part of the YY/T 1649 series on the interaction of medical devices with blood. Issued on 31 May 2019, it has applied since 1 June 2020.
Found what you need?
Document preview — YY/T 1649.1-2019
National Standard of the People's Republic of China
- ICS
- 11.040.01
- Classification
- C 30
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Overview
- 5 Reagents and materials
Foreword
YY/T 1649 "Medical Device and Platelet Interaction Test" is divided into the following sections.
--- Part 1. In vitro platelet counting method;
--- Part 2. In vitro platelet activation test. This part is the first part of YY/T 1649.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
Introduction
The test methods for the blood compatibility of medical devices/materials and the selection strategies for the tests are given in GB/T 16886.4. But only given Choose the principle. This part of YY/T 1649 is a specific test method for in vitro platelet count, which can be used as a medical device in GB/T 16886.4.
Supplement to the evaluation of the interaction of the device/material with platelets.
As an important component of blood, platelets play a key role in preventing bleeding. The decrease in the number of platelets in the blood after contact with the device is caused by Caused by the action of platelet adsorption, aggregation or activation, it will directly affect the blood compatibility of medical devices/materials. YY/T 1649 of this Part of the method for determining in vitro platelet counts can be used to screen medical devices with potential platelet adhesion and activation. material.
1 Scope
This part of YY/T 1649 specifies the use of medical devices/materials for in vitro and platelet interaction in blood compatibility assessment. Platelet count test method used.
This section applies to the evaluation of platelet adhesion properties and activation potential on medical devices/materials.
The test system established in this section is applicable to human blood. The test is carried out using animal blood. Refer to this section and its suitability should be carried out. Argument.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 16886.1 Biological evaluation of medical devices - Part 1. Evaluation and testing in the process of risk management (GB/T 16886.1- 2011, ISO 10993-1.:2009, IDT)
GB/T 16886.4 Biological evaluation of medical devices - Part 4. Selection of test for interaction with blood (GB/T 16886.4-2003,
ISO 10993-4:2002, IDT)
3 Terms and definitions
The terms and definitions defined in GB/T 16886.1 and GB/T 16886.4 apply to this document.
4 Overview
When medical devices/materials come into contact with human blood, platelets in the blood may adhere to the surface of the medical device/material and potential Activation reaction. When the medical device/material is in contact with blood, the number of platelets in the blood is significantly reduced, indicating that platelet has occurred.
Adhesion and activation may be associated with induction of thrombosis in vivo.
5 Reagents and materials
5.1 Reagents
5.1.1 Controls or other reference materials suitable for blood analyzer calibration.
5.1.2 Fresh healthy anticoagulant human whole blood.
Note. After the test is over, the blood and blood contact items should be disposed according to relevant regulations.
5.1.3 EDTA salt solution (analytical grade), 500 mmol/L
5.1.4 0.9% sodium chloride injection, for selection.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 1649.1-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 16886.4-2022 — Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood
YY/T 1649.2-2019 — Test method for interactions of medical devices with platelets - Part 2: In vitro platelet activation products (beta-TG, PF4 and TxB2) assay
Secure payment via Stripe
Payments accepted
YY/T 1649.1-2019
$90.00