Scope
YY/T 1287.1-2016 is the English-translated version of 颅外引流系统 第1部分:颅脑穿刺外引流收集装置.
YY/T 1287.1-2016 is the Chinese pharmaceutical industry standard for the external drainage device used after cranial puncture, part of the external cerebrospinal fluid drainage system.
It is the first part of the YY/T 1287 series and sets the requirements for the device used to drain cerebrospinal fluid and to drain an intracerebral haemorrhage or haematoma, covering the collection chamber and its graduations, the pressure level setting, the tubing, connectors and filters, the tightness and the strength of the assembly, the materials and their biological evaluation and sterility. Issued on 23 March 2016, it has applied since 1 January 2017.
Found what you need?
Document preview — YY/T 1287.1-2016
National Standard of the People's Republic of China
- Classification
- C 30
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Structure and Name
- 5 Material
- 6 Physical requirements
- 7 Chemical requirements
- 8 Biological requirements
- 9 type test
- 10 logo
- 11 Packing
- Appendix A (Normative Appendix) Physical Test Method Reference
Foreword
YY/T 1287 "External Brain Drainage System" is divided into the following three parts.
--- Part 1. Brain puncture external drainage collection device;
--- Part 2. Lumbar puncture cerebrospinal fluid drainage device;
--- Part 3. Extracranial drainage catheter. This part is the first part of YY/T 1287.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
Introduction
The extracranial drainage device is suitable for drainage of patients with cerebrospinal fluid and patients with less cerebral hemorrhage (or hematoma). Cerebrospinal fluid is in the brain The liquid in the spine that communicates with it can be clinically introduced into other parts of the body through shunting in the body, and can also be passed as appropriate.
Extracorporeal drainage (belonging to extracranial drainage) or extra-vertebral drainage leads it out of the body; cerebral hemorrhage (or blood outside the brain and under the skull)
Swelling can be taken out of the body by external drainage of the brain.
The device specified in this section is used for extraventricular drainage of the cerebrospinal fluid and external drainage of cerebral hemorrhage (or hematoma). The former needs ventricular pressure monitoring and Regulatory device.
For the in vivo shunt cerebrospinal fluid shunt, see YY/T 0487, "Single-use sterile hydrocephalus and its components." Extracranial drainage system Part 1. Brain puncture external drainage collection device
1 Scope
This part of YY/T 1287 specifies the requirements for the external drainage device for craniocerebral puncture in the extracranial drainage system. It is suitable for cerebrospinal fluid.
External drainage of the brain and external drainage of cerebral hemorrhage (or hematoma).
The requirements for devices for external drainage of the lumbar puncture, extracranial drainage catheters, and intracranial pressure monitoring devices are not within the scope of this section.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 1962.2 Syringes, needles and other medical devices 6% (Ruhr) conical joints Part 2. Locking joints (GB/T 1962.2-2001, ISO 594-2.:1998, IDT)
GB 8368-2005 Disposable infusion set gravity infusion (ISO 8536-4:2004, MOD)
GB/T 16886.1 Biological evaluation of medical devices - Part 1. Evaluation and testing in the process of risk management (GB/T 16886.1- 2011, ISO 10993-1.:2009, IDT)
GB 17257.2-2009 Urine collection bag Part 2. Requirements and test methods (ISO 8669-2:1996, IDT)
YY/T 0466.1 Medical devices for use in medical devices - signs, labels and symbols for information - Part 1. General requirements (YY/T 0466.1-2009, ISO 15223-1:2007, IDT)
YY 0581.1-2011 Infusion connector Part 1. Puncture connector (heparin cap)
YY 0581.2-2011 Infusion connection parts - Part 2. Needle-free connectors
YY 0585.2-2005 Disposable fluid circuits for pressure infusion devices and their accessories - Part 2. Accessories (ISO 8536-10. 2004, IDT)
YY/T 0615.1 Requirements for "sterile" medical devices - Part 1. Requirements for terminally sterilized medical devices
YY/T 1551 Air filtration material for infusion and blood transfusion apparatus
ISO 11607-1:2006 Packaging of terminally sterilized medical devices - Part 1. Requirements for materials, sterile barrier systems and packaging systems 1)
1) China's standard GB/T 19633.1 equivalent to ISO 11607-1:2006 is currently in the approval stage.
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Extracranial drainage
Intracranial effusion [including cerebrospinal fluid, cerebral hemorrhage (hematoma), cerebral cyst fluid, etc.] through brain puncture or lumbar puncture (cerebrospinal fluid) drainage Drainage to the outside of the body.
3.2 External puncture drainage
The drainage of the intracranial effusion through the cranial puncture is drained to the drainage in vitro.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1962.2Conical fittings with a 6 %(Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings
- GB 8368-2005Infusion sets for single use -- Gravity feed
- GB/T 16886.1Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
- YY/T 0466.1Medical devices - Symbols to be used with information to be supplied by the manufacturer - Part 1: General requirements
- YY 0581.1-2011Infusion access adapters - Part 1: Needle access adapters(Heparin plugs)
- YY 0581.2-2011Infusion access adapter - Part 2: Needleless access adapters
GB 17257.2-2009 · YY/T 1551 · ISO 11607-1:2006
Similar standards
How to Download YY/T 1287.1-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 1962.2-2001 — Conical fittings with a 6 %(Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings
YY 0581.1-2011 — Infusion access adapters - Part 1: Needle access adapters(Heparin plugs)
Secure payment via Stripe
Payments accepted
YY/T 1287.1-2016
$235.00