Valid

YY/T 1195-2011Reference measurement procedure of total protein in serum (English PDF)

血清总蛋白参考测量程序

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1195-2011 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

December 31, 2011

Implementation date

June 1, 2013

Scope

YY/T 1195-2011 is the English-translated version of 血清总蛋白参考测量程序.

YY/T 1195-2011 is the Chinese pharmaceutical industry standard that fixes the reference measurement procedure for the total protein content of serum.

It sets out the principle of the procedure and the reagents and apparatus it requires, the preparation of the sample, the measurement and the calculation of the result, and the performance the procedure must show, so that it can serve to assign values to reference materials and to assess routine methods. Issued on 31 December 2011, it has applied since 1 June 2013.

Found what you need?

Document preview — YY/T 1195-2011

National Standard of the People's Republic of China

ICS
11.100
Classification
C 44

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

Introduction

Biuret method for measuring serum total protein has been nearly a hundred years of history, in this process, many researchers measured their system Optimized 1974 American Association for Clinical Chemistry (AACC) total protein study group this method was more in-depth studies, the establishment Serum total protein reference measurement procedures and findings in the American Journal of ClinicalChemistry continuously published. The final Senate Test methods recognized standards agency and became the Joint Commission Laboratory Medicine Traceability (JCTLM, JointCommitteefor TraceabilityinLaboratoryMedicine) Recommended total serum protein reference measurement procedures. This standard is based on this reference measurement procedures Making. Serum total protein reference measurement procedures

1 Scope

This standard is used for quantitative measurement of serum total protein content.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

Laboratory use specifications and test methods GB/T 6682-2008 Analysis JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Sensitivity analysis

The sensitivity of the measurement program sensitivityofameasurementprocedure Measurements indicating values divided by the corresponding change of the measured value quotient.

Note 1. The sensitivity of the measurement procedure is likely to be dependent on the measured value.

Note 2. To investigate the changes must be greater than the measured value resolution.

Note 3. a measuring system sensitivity analysis is the slope of the calibration curve.

Note 4. The analytical sensitivity should not be used to indicate the limit of quantification or detection limit, and should not be confused with the diagnostic sensitivity. [ISO 18113-1:2009, defined A3.3]

3.2 Linearityofameasuringsystem linear measuring system

Linear linearity Values are given in the sample to be measured is directly measured value of the ability to scale.

Note 1. For in vitro diagnostic medical devices, linear and linear measurement calibration or indication of a given measurement result of the measurement interval related.

Note 2. Linear assessed by measuring the recipe which contains known or known relative relationship (not necessarily absolute knowledge) is measured samples. Relative is measured when the measurement result Absolute or relative value is plotted, the curve of the line plan that is a measure of degree of compliance linearity. [ISO 18113-1:2009, defined A3.21]

3.3 Influence quantity

In direct measurement, does not affect the actual amount to be measured, but the amount of influence between the indication and the measurement result of the relationship.

Example 1. direct measurement of hemoglobin concentration in human plasma bilirubin concentrations.

Example 2. measurement of the background pressure in the mass spectrometer ion source in a fraction of the amount of substance.

Note 1. Indirect Measurement combination comprising direct measurements, wherein each measurement can be affected by the amount of impact.

Note 2. In the GUM, the concept is defined as the amount of influence a previous version of VIM, covering not only the amount of influence the measuring system, as defined above, but also that These affect the actual amount was measured quantity. Further, in the GUM this concept is not limited to direct measurement.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 1195-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1195-2011

$255.00