YY/T 0980.1-2016Biopsy needles for single use - Part 1: General requirements (English PDF)
一次性使用活组织检查针 第1部分:通用要求
This is a limited preview
Buy now to download the full PDF (31 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0980.1-2016 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
March 23, 2016
Implementation date
January 1, 2017
Scope
YY/T 0980.1-2016 is the English-translated version of 一次性使用活组织检查针 第1部分:通用要求.
YY/T 0980.1-2016 is the Chinese pharmaceutical industry standard that sets the general requirements for single-use biopsy needles, the needles used to take a living tissue sample for examination.
It classifies them by the way the sample is taken - aspiration or cutting - by how they are driven, manually or by a mechanical power device, and by their intended use, and it fixes the model marking and the structure of the needle.
The requirements cover the sampling structure, the stainless steel and titanium materials, dimensional tolerance, appearance and cleanliness, the needlepoint, the collection space, the pull-out load between needle tube and needle seat, rigidity, elasticity and toughness, the 6% Luer cone of the needle seat, sterility, chemical performance and biological evaluation, together with packaging and marking.
It is a modified adoption of JIS T 3228:2011 and does not apply to reusable biopsy needles. Issued on 23 March 2016, it has applied since 1 January 2017.
Found what you need?
Document preview — YY/T 0980.1-2016
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword4
- 1 Scope5
- 2 Normative References5
- 3 Terms and Definitions6
- 4 Classification and Mark8
- 4.1 Classification8
- 4.2 Mark8
- 4.3 Structure9
- 5 Requirements12
- 5.1 Sampling structure of biopsy needle12
- 5.2 Materials12
- 5.3 Dimensional tolerance13
- 5.4 Appearance and cleanliness13
- 5.5 Needlepoint13
- 5.6 Sample collection space and smoothness13
- 5.7 Connecting firmness14
- 5.8 Rigidity and elasticity14
- 5.9 Toughness15
- 5.10 Cone joint of needle seat16
- 5.11 Biological performance16
- 5.12 Chemical performance16
- 5.13 Biological evaluation17
- 6 Package17
- 6.1 Sterile primary packaging17
- 6.2 Outer packaging17
- 7 Mark17
- 7.1 Sterile primary packaging17
- 7.2 Outer packaging18
- 7.3 Pictogram18
- Appendix A (Informative) Structure changes between this Part and JIS T 3228.201119
- Appendix B (Informative) Technical differences and causes between this Part and JIS T 3228:201122
- Appendix C (Informative) Guidelines for biopsy needle rigidity and structural size29
- Bibliography31
Foreword
YY/T 0980 Biopsy Needles for Single Use can be divided into the following 4 parts.
-- Part 1: General Requirements;
-- Part 2: Manual Biopsy Needle;
-- Part 3: Mechanical Assembly Type;
-- Part 4: Mechanical Complete Type.
This Part belongs to Part 1 of YY/T 0980 Biopsy Needles for Single Use.
This Part was drafted as per the rules specified in GB/T 1.1-2009.
This Part modifies and adopts JIS T 3228:2011 Biopsy Needles for Single Use.
Compared with JIS T 3228:2011, this Part has more adjustments in structure; Appendix A list the Clause Number Comparison List between This Part and JIS T 3228:2011.
There is technical difference between this Part and JIS T 3228:2011; Appendix B gives the Corresponding Technical Differences and Causes List.
1 Scope
This Part of YY/T 0980 specifies the general requirements of biopsy needle for single use (hereinafter referred to as biopsy needle).
This Part is applicable to the biopsy needle for single use for sample collection of living tissue for inspection.
This Part is not applicable to biopsy needle for repeated use, and the mechanical power device connected with the biopsy needle by means of assembly.
2 Normative References
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.
GB/T 1220-2007 Stainless-steel Bars
GB/T 1962.1 Conical Fittings with a 6% (Luer) Taper for Syringes, Needles and Certain Other Medical Equipment - Part 1: General Requirement
GB/T 1962.2 Conical Fittings with a 6% (Luer) Taper for Syringes, Needles and Certain Other Medical Equipment - Part 2: Lock Fittings
GB/T 2965 Titanium and Titanium Alloy Bars
GB/T 14233.1-2008 Test Methods for Infusion Transfusion Injection Equipment for Medical Use - Part 1: Chemical Analysis Methods
3 Terms and Definitions
The following terms and definitions are applicable to this document.
3.6 Fabricated mechanical power needle biopsy [Translator note. should be biopsy needle]
3.1 Biopsy
The method to obtain living tissue sample from the patient body for the pathological examination and disease diagnosis.
3.2 Biopsy needle
Needle medical device for collecting the living tissue sample.
3.3 Aspiration biopsy needle
The biopsy needle collecting the living tissue sample through aspiration, the front end of the needle body shall be designed as a puncture structure and retain sample aspiration collection space; it can be used alone or coordinate with aspirator to use.
3.4 Cutting biopsy needle
The biopsy needle collecting the living tissue sample through cutting the living tissue, the front end of the needle body shall be designed as puncture structure and retain sample cutting collection space.
3.5 Manual biopsy needle
The biopsy needle collecting the living tissue sample through manual operation.
The biopsy needle, before use, the biopsy needle body is assembled with the reusable mechanical power device; automatically or semi-automatically collecting the living tissue sample by means of mechanical power device.
4 Classification and Mark
4.1 Classification
4.1.1 According to the method to obtain the biopsy sample through the biopsy needle, it can be divided into.
4.1.2 According to the method to use biopsy needle, it can be divided into.
4.1.3 According to the usage of biopsy needle, it can be divided into.
4.2 Mark
4.2.1 Model mark
The model mark of biopsy needle consists of English letters and Arabic numerals; the expression method is as follows.
4.3 Structure
The needle part of the biopsy needle is composed of single needle tube and needle Design style code
5 Requirements
5.1 Sampling structure of biopsy needle
The sampling structure of biopsy needle shall at least include one of the following modes.
5.2 Materials
5.2.1 Needle tube materials
The needle tube shall be made of the following materials.
5.2.2 Needle seat or relevant accessories materials
The materials of needle seat or relevant accessories that in direct or indirect contact with the human body shall meet the requirements of 5.11, 5.12, and 5.13 in this Part.
5.5 Needlepoint
The needlepoint cutting edge shall be sharp; use the 2.5× magnifier to check there shall be no visible hook head, flat head, burs or the like defects.
5.7 Connecting firmness
5.7.1 According to nominal outside diameter or outside diameter on the minimum cross-section of the biopsy needle, exert the axial static tension specified in Table 2 on the needle tube and needle seat, last for 10s, the two of which shall not be separated.
5.8 Rigidity and elasticity
5.8.1 For the needle tube adopting the stainless-steel materials specified in GB/T 18457-2015, and applicable to the inside and outside diameter sizes listed in Table 1, its rigidity shall meet the requirements of such standard.
5.9 Toughness
5.9.1 For the needle tube adopting the stainless-steel materials specified in GB/T 18457-2015, and applicable to the inside and outside diameter size series listed in
5.11 Biological performance
5.11.1 Sterile
The biopsy needle ensures the sterility of the product through confirmation of sterilization process and routine control.
5.13 Biological evaluation
Perform the biological evaluation against the biopsy needle as per the method specified in GB/T 16886.1.
6 Package
6.1 Sterile primary packaging
The sterile primary packaging shall meet the requirements of GB/T 19633.1; ensure that it is not easy to be broken before use, and can prevent the microbial invasion.
6.2 Outer packaging
The outer packaging shall have the strength to protect the content products under the normal disposing, transporting and storing conditions.
7 Mark
7.1 Sterile primary packaging
The sterile primary packaging shall have the following marks at least.
7.2 Outer packaging
The outer packaging shall have the following marks at least.
7.3 Pictogram
The pictogram shall conform to the provisions of YY/T 0466.1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 31 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1220-2007Stainless steel bars
- GB/T 1962.1Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirement
- GB/T 1962.2Conical fittings with a 6 %(Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings
- GB/T 2965Titanium and titanium alloy bars
- GB/T 14233.1-2008Test methods for infusion, transfusion, injection equipments for medical use - Part 1: Chemical analysis methods
Similar standards
How to Download YY/T 0980.1-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1220-2007 — Stainless steel bars
GB/T 14233.1-2008 — Test Methods for Infusion, Transfusion, Injection Equipment for Medical Use — Part 1: Chemical Analysis Methods
GB/T 1962.1-2015 — Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirement
Secure payment via Stripe
Payments accepted
YY/T 0980.1-2016