YY/T 0920-2014Non-active surgical implants—Joint replacement implants—Specific requirements for hip-joint replacement implants (English PDF)
无源外科植入物 关节置换植入物 髋关节置换植入物的专用要求
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0920-2014 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
June 17, 2014
Implementation date
July 1, 2015
Scope
YY/T 0920-2014 is the English-translated version of 无源外科植入物 关节置换植入物 髋关节置换植入物的专用要求.
YY/T 0920-2014 is the Chinese pharmaceutical industry standard that sets the specific requirements for hip joint replacement implants among the non-active surgical implants.
As regards safety it fixes the intended performance of the implant, its design attributes, the materials, the preclinical evaluation, the manufacture, the sterilization and the packaging, and the information the manufacturer must provide, covering the articulating surfaces and their wear, the stem and the cup and the fixation of each, and the mechanical strength of the components and of their assembly. Issued on 17 June 2014, it has applied since 1 July 2015.
Found what you need?
Document preview — YY/T 0920-2014
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword3
- Introduction5
- 1 Scope6
- 2 Normative references6
- 3 Terms and definitions7
- 4 Expected performance8
- 5 Design attributes8
- 6 Materials9
- 7 Design evaluation10
- 8 Manufacturing11
- 9 Sterilization11
- 10 Packaging11
- 11 Information provided by the manufacturer11
- Appendix A (Informative) Evaluation of relative angular motion of components14
- References16
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is translated and identical to ISO 21535:2007 Non-active surgical implants - Joint replacement implants - Specific requirements for hip-joint replacement implants.
The Chinese documents that have consistent correspondence with the international documents normatively cited in this standard are as follows:
-- YY/T 0640-2008 Non-active surgical implants - General requirements (ISO 14630:2005, IDT)
-- YY/T 0809.1 Implants for surgery - Partial and total hip joint prostheses - Part 1: Classification and designation of dimensions (YY/T 0809.1-2010, ISO 7206-1:2008, IDT)
-- YY/T 0809.2 Implants for surgery - Partial and total hip joint prostheses - Part 2: Articulating surfaces made of metallic, ceramic and plastic materials (YY/T 0809.2-2010, ISO 7206-2:1996, MOD)
-- YY/T 0809.4 Implants for surgery - Partial and total hip joint prostheses - Part 4: Determination of endurance properties of stemmed femoral components (YY/T 0809.4-2010, ISO 7206-4:2002, MOD)
-- YY/T 0809.6 Implants for surgery - Partial and total hip joint prostheses - Part 6: Determination of endurance properties of head and neck region of stemmed femoral components (YY/T 0809.6-2010, ISO 7206-6:1992, MOD)
1 Scope
This standard specifies specific requirements for hip joint replacement implants.
With regard to safety, this standard specifies requirements for expected performance, design attributes, materials, design evaluation, fabrication, sterilization, packaging, and information provided by the manufacturer, as well as test methods.
2 Normative references
The following documents are essential to the application of this document. For the dated referenced documents, only the versions with the indicated dates are applicable to this document; for the undated referenced documents, only the latest version (including all the amendments) is applicable to this document.
YY/T 0640-2008 Non-active surgical implants - General requirements (ISO 14630:2005, IDT)
YY/T 0809.1 Implants for surgery - Partial and total hip joint prostheses - Part 1: Classification and designation of dimensions (YY/T 0809.1-2010, ISO 7206-1:2008, IDT)
YY/T 0809.2-2010 Implants for surgery - Partial and total hip joint prostheses - Part 2: Articulating surfaces made of metallic, ceramic and plastic materials (ISO 7206-2:1996, MOD)
YY/T 0809.4 Implants for surgery - Partial and total hip joint prostheses - Part 4: Determination of endurance properties of stemmed femoral components (YY/T 0809.4-2010, ISO 7206-4:2002, MOD)
YY/T 0809.6-2010 Implants for surgery - Partial and total hip joint prostheses - Part 6: Determination of endurance properties of head and neck region of stemmed femoral components (ISO 7206-6:1992, MOD)
YY/T 0809.10 Implants for surgery - Partial and total hip joint prostheses - Part 10: Determination of resistance to static load of modular femoral heads (YY/T 0809.10-2010, ISO 7206-10:2003, MOD)
11 Information provided by the manufacturer
11.3 Structural and functional compatibility of components
11.3.1 If a femoral component or modular femoral head is only expected to be compatible with the structures and functions of specific acetabular cups, the compatible acetabular cups shall be stated in its label, instruction leaflet, or manual.
11.3.2 If an acetabular component is only expected to be compatible with the structures and functions of specific femoral components, the compatible femoral components shall be stated in its label, instruction leaflet, or manual.
11.3.3 For a femoral component and head of modular construction, the label, instruction
leaflet, or manual shall state for each, the corresponding components with which they are structurally and functionally compatible.
NOTE: In general, components made by different companies may not match. This applies in particular to modular components with male or female tapered connections.
11.4 Marking
11.4.1 The nominal diameter of the femoral head shall be marked on a monobloc femoral component.
11.4.2 A modular femoral head shall be marked to identify its nominal outer diameter and the characteristics of the cone and bore connection. In normal or corrected vision, these markings shall be legible.
11.4.3 For the stemmed femoral component of the hip joint replacement implant matched with the modular femoral head in the way of a male/female tapered connection, as long as the expected function of the component is not damaged, there shall be a mark indicating the connection method. Markings required for identification or other reasons may be located on the neck of the femoral component of a hip joint replacement implant only if it is proven that endurance property will not be impaired. For stemmed femoral components fitted with modular femoral heads, the marking shall be located on the proximal end face of the conical region where the femoral head is fitted. In normal or corrected vision, the marking shall be clear.
11.4.4 The acetabular component with the articular surface of a total hip joint
arthroplasty shall be marked with the nominal diameter of the articular surface. In normal or corrected vision, the marking shall be clear.
11.5 Information provided to patients
The manufacturer shall at least make the following statement or equivalent statement in the instruction leaflet or manual:
"Patients receiving hip joint replacements should be advised that the longevity of the […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Referenced standards
Normative references
- YY/T 0640-2008Non-active surgical implants - General requirements
- YY/T 0809.1Implants for surgery-Partial and total hip joint prostheses - Part 1: Classification and designation of dimensions
- YY/T 0809.2-2010Implants for surgery—Partial and total hip joint prostheses - Part 2: Articulating surfaces made of metallic, ceramic and plastics materials
- YY/T 0809.4Implants for surgery—Partial and total hip joint prostheses - Part 4: Determination of endurance properties and performance of stemmed femoral components
- YY/T 0809.6-2010Implants for surgery—Partial and total hip joint prostheses - Part 6: Endurance properties testing and performance requirements of neck region of stemmed femoral components
- YY/T 0809.10Implants for surgery-Partial and total hip-joint prostheses - Part 10: Determination of resistance to static load of modular femoral heads
Similar standards
How to Download YY/T 0920-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0640-2008 — Non-active surgical implants—General requirements
YY/T 0809.1-2010 — Implants for surgery-Partial and total hip joint prostheses - Part 1: Classification and designation of dimensions
YY/T 0809.10-2014 — Implants for surgery—Partial and total hip joint prostheses - Part 10: Determination of resistance to static load of modular femoral heads
Secure payment via Stripe
Payments accepted
YY/T 0920-2014
$185.00