YY/T 0647-2021Non-active surgical implants-Particular requirements of mammary implants (English PDF)

无源外科植入物 乳房植入物的专用要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (52 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0647-2021 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

December 6, 2021

Implementation date

December 1, 2022

Scope

YY/T 0647-2021 is the English-translated version of 无源外科植入物 乳房植入物的专用要求.

YY/T 0647-2021 is the Chinese pharmaceutical industry standard that sets the particular requirements for mammary implants as non-active surgical implants.

It covers the intended performance of the implant, its design attributes, the materials it is made from, the design evaluation, the manufacturing, the packaging and the sterilization, and the information the manufacturer must supply, so that the safety of the implant is addressed through the whole of its development and production rather than by a final test alone.

It replaces YY 0647-2008, was issued on 6 December 2021 and has applied since 1 December 2022.

Found what you need?

Document preview — YY/T 0647-2021

National Standard of the People's Republic of China

Replacing
YY 0647-2008

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword3
  • Introduction6
  • 1 Scope7
  • 2 Normative References7
  • 3 Terms and Definitions8
  • 4 Intended Performance10
  • 5 Design Attributes10
  • 6 Materials10
  • 7 Design Evaluation12
  • 8 Manufacturing15
  • 9 Sterilization15
  • 10 Packaging15
  • 11 Information Supplied by the Manufacturer15
  • Appendix A (Normative) Determination of Octamethylcyclotetrasiloxane (D4) and Decamethylcyclopentasiloxane (D5) in Silicone Gels18
  • Annex B (Normative) Tests for Shell Integrity22
  • Annex C (Normative) Mechanical Tests on a Mammary Implant in its Implantable State .25
  • Annex D (Normative) Test Method for Valve Competence and Injection Site Competence31
  • Annex E (Normative) Test for Silicone Gel Cohesion (Silicone Filling Materials Only) .34
  • Annex F (Normative) Test for Silicone Gel Penetration (Silicone Filling Materials Only) .36
  • Annex G (Informative) Assessment of Silicone Diffusion from Mammary Implants Using an in Vitro Method41
  • Annex H (Informative) Test for Surface Characteristics46
  • Annex I (Normative) Information for the User49
  • Annex J (Normative) Information for the Patient50
  • Bibliography52

Foreword

This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for Standardization - Part 1: Rules for the Structure and Drafting of Standardizing Documents.

This Document replaced YY 0647-2008 Non-Active Surgical Implants - Mammary Implants - Particular Requirements. Compared with YY 0647-2008, the major technical changes of this Document are as follows.

--- Add the requirements and test methods for the cytotoxicity test of raw materials (see 6.2 of this Edition);

--- Add the requirements and test methods for residual low molecular weight oligomers in silica gel (see 6.3 of this Edition);

--- Add the limit requirements for trace elements of raw materials (see 6.4 of this Edition);

--- Add test methods for physical and mechanical properties and characterization of raw materials (see 6.5 of this Edition);

--- Modify the requirements and test methods for fatigue tests (see 7.2.2.2.1 of this Edition;

7.2.2.5.2 of 2008 Edition);

--- Delete the tear resistance of the shell (see 7.2.2.2.3 of 2008 Edition);

--- Delete the static rupture test (see 7.2.2.5.4 of 2008 Edition);

--- Add the test method for silicone gel penetration test (see 7.2.3.3.3 of this Edition);

--- Modify the test method of the diffusion test (see 7.2.3.4 of this Edition; 7.2.3.4 of 2008 Edition);

--- Modify the test method for surface properties (see 7.2.3.7 of this Edition; 7.2.2.8 of 2008 Edition);

--- Add requirements for surface particle contamination (see 7.2.3.8 of this Edition).

This Document uses translation method to equivalently adopt ISO 14607:2018 Non-Active Surgical Implants - Mammary Implants - Particular Requirements.

The Chinese documents that have a consistent correspondence with the international documents normatively cited in this Document are as follows.

--- GB/T 528-2009 Rubber, Vulcanized or Thermoplastic - Determination of Tensile Stress- Strain Properties (ISO 37:2005, IDT);

--- GB/T 529-2008 Rubber Vulcanized or Thermoplastic - Determination of Tear Strength (Trouser, Angle and Crescent Test Pieces) (ISO 34-1:2004, MOD);

--- GB/T 531.1-2008 Rubber Vulcanized or Thermoplastic - Determination of Indentation Hardness - Part 1: Durometer Method (Shore Hardness) (ISO 7619-1:2004, IDT);

--- GB/T 3505-2009 Geometrical Product Specifications (GPS) - Surface Texture. Profile Method - Terms Definitions and Surface Texture Parameters (ISO 4287:1997, IDT);

--- GB/T 16886.1-2011 Biological Evaluation of Medical Devices - Part 1: Evaluation and Testing Within a Risk Management Process (ISO 10993-1:2009, IDT);

--- GB/T 16886.5-2017 Biological Evaluation of Medical Devices - Part 5: Tests for in Vitro Cytotoxicity (ISO 10993-5:2009, IDT);

--- GB/T 16886.18-2011 Biological Evaluation of Medical Devices - Part 18: Chemical Characterization of Materials (ISO 10993-18:2005, IDT);

--- GB/T 19633.1-2015 Packaging for Terminally Sterilized Medical Devices - Part 1.

Requirements for Materials, Sterile Barrier Systems and Packaging Systems (ISO 11607- 1.2006, IDT);

--- YY/T 0297-1997 Clinical Investigation of Medical Devices (ISO 14155:1996, IDT). This Document made the minimum editorial modifications as follows.

--- In order to coordinate with the current standard, change the standard name into Non- Active Surgical Implants - Particular Requirements of Mammary Implants.

Please note some contents of this Document may involve patents. The issuing agency of this Document shall not assume the responsibility to identify these patents.

1 Scope

This Document specifies particular requirements for mammary implants.

With regard to safety of the implants, this Document specifies requirements for intended performance, design attributes, materials, design evaluation, manufacturing, packaging, sterilization, and information supplied by the manufacturer.

2 Normative References

The provisions in following documents become the essential provisions of this Document through reference in this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document.

YY/T 0640-2016 Non-Active Surgical Implants - General Requirements (ISO 14630:2012, IDT)

3 Terms and Definitions

For the purposes of this Document, the terms and definitions given in ISO 10993-1, ISO 14155 and YY/T 0640 and the following apply.

Volume of the material contained within the shell (3.11) or volume of the solution necessary to fill an inflatable or adjustable mammary implant (3.8).

4 Intended Performance

The requirements of YY/T 0640-2016, Clause 4, shall apply.

5 Design Attributes

The requirements of YY/T 0640-2016, Clause 5, shall apply.

6 Materials

The components of each production raw material lot shall be cured and tested for cytotoxicity in accordance with ISO 10993-5.No cytotoxic effects, as defined in ISO 10993-5, shall be induced by the material tested, or throughout the culture.

7 Design Evaluation

The pre-clinical evaluation of mammary implants shall conform to YY/T 0640-2016, 7.2, and fulfil the requirements of ISO 10993-1. The integrity of the shell shall be evaluated.

8 Manufacturing

The requirements of YY/T 0640-2016, Clause 8, shall apply.

9 Sterilization

The requirements of YY/T 0640-2016, 9.1, 9.2 and 9.4, shall apply. Implants shall be supplied sterile.

10 Packaging

The requirements of YY/T 0640-2016, Clause 10, apply. Packaging design shall be validated according to ISO 11607-1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 52 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of YY/T 0647

EditionTitleRevisionStatus
YY/T 0647-2021Non-active surgical implants-Particular requirements of mammary implantscurrent editionCurrent
YY 0647-2008Non-active surgical implants-Particular requirements of mammary implantsprevious editionSuperseded

This page sells the current edition, YY/T 0647-2021. Earlier editions are listed for reference only.

How to Download YY/T 0647-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
52 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0647-2021

$485.00