Valid

YY/T 0829-2011Characteristics and test methods for imaging system of positron emission and X-ray computed tomography (English PDF)

正电子发射及X射线计算机断层成像系统性能和试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (26 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0829-2011 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

December 31, 2011

Implementation date

June 1, 2013

Scope

YY/T 0829-2011 is the English-translated version of 正电子发射及X射线计算机断层成像系统性能和试验方法.

YY/T 0829-2011 is the Chinese pharmaceutical industry standard that fixes the characteristics and the test methods of the imaging system of a combined positron emission and X-ray computed tomography scanner.

It gives the terms and definitions and covers the spatial resolution, the sensitivity, the count rate performance and the scatter fraction of the PET part, the image quality and the dose of the CT part, the accuracy of the attenuation correction and of the registration between the two data sets. Issued on 31 December 2011, it has applied since 1 June 2013.

Found what you need?

Document preview — YY/T 0829-2011

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C 43

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Performance

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

Introduction

Positron emission and X-ray computed tomography system in positron emission tomography section (hereinafter referred to as PET portion)

Reference and test methods for performance standards for GB/T 18988.1-2003, X-ray computed tomography section (hereinafter referred to as CT section) Performance criteria and test methods cited YY 0310-2005.

GB/T 18988.1-2003 identical with the IEC 61675-1:1998. Currently, a major manufacturer of radionuclide imaging apparatus Production sites are located in the United States, are NEMA National Electrical Manufacturers Association for its report parameters, data processing software, test phantom Standards as a basis for the design, but also manufacturers use IEC standard. In order to facilitate the government, enterprises and medical institutions understand and use such production Products two series IEC and NEMA standard content, radiotherapy, nuclear medicine science equipment at the Technical Committee and the radiation dose (SAC / TC10/SC3) with the consent and support of NEMA Board's NEMA Standards Publication NU2-2007 "as positron emission tomography Like device performance test "incorporated this standard, the NEMA standard as a normative appendix to this standard.

Since the IEC and NEMA standards there are some differences in testing requirements, test methods, the use of motifs, test conditions, test Position, the calculation method is different, so I can not compare with each other between the two standard test items and complete references recommend two standard user The method of any one species should not be used interchangeably.

1 Scope

This standard specifies the positron emission and X-ray computed tomography system (hereinafter referred to as PET/CT) terms, definitions and sexual Energy and test methods.

This standard applies to PET/CT, does not apply to independent positron emission tomography apparatus (PET) and a separate X-ray computed Tomography apparatus (CT).

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 17857-1999 Medical imaging academic language (radiotherapy, nuclear medicine and radiation dosimetry equipment)

GB/T 18988.1-2003 Radionuclide imaging device - Characteristics and test - Part 1. Positron emission tomography Equipment

YY 0310-2005 X-ray computer tomography equipment general technical conditions

3 Terms and Definitions

GB/T 17857-1999, GB/T 18988.1-2003, YY 0310-2005 as defined in the following terms and definitions apply This document.

3.1 Attenuation correction

After radiation of medium strength loss correction. Attenuation caused by absorption or scattering. In the body by correcting the actual attenuation required Measuring the linear attenuation coefficient. General use of radioactive sources or X-ray transmission scan to determine the attenuation coefficient.

3.2 Image registration

The different sets of image data conversion process to the same coordinate system. Different image data set is a different time and (or) different models of the same Obtaining a data set collected objects.

4 Performance

4.1 PET part of the performance and test methods

4.1 And performance

and test methods specified in Appendix A can choose one, the proposed standard users complete reference in either of two methods It one of the cross should not be used.

4.1.1 Spatial resolution

Press Test GB/T 18988.1-2003 be specified in 3.1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 26 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0829-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
26 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0829-2011

$465.00