GB/T 18988.1-2025Radionuclides imaging devices - Characteristics and test conditions - Part 1: Positron emission tomographs (English PDF)

放射性核素成像设备 性能和试验规则 第1部分:正电子发射断层成像装置

Preview PDF

This is a limited preview

Buy now to download the full PDF (54 pages)

Need quotation for your management?

Get a formal quotation for GB/T 18988.1-2025 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Recommended

Issue date

October 31, 2025

Implementation date

May 1, 2027

Scope

GB/T 18988.1-2025 is the English-translated version of 放射性核素成像设备 性能和试验规则 第1部分:正电子发射断层成像装置.

GB/T 18988.1-2025 — This document specifies the test methods and accompanying documentation for the performance of positron emission tomography (PET) devices. This document applies to positron emission tomography (PET) devices.

Found what you need?

Document preview — GB/T 18988.1-2025

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C 43
Replacing
GB/T 18988.1-2013

Issued by: State Administration for Market Regulation

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative References
  • 3 Terms and Definitions
  • 4 Test methods 6.
  • 4.1 General Rules
  • 4.2 Spatial Resolution
  • 4.3 Tomographic imaging sensitivity
  • 4.4 Scattering fraction
  • 4.5 PET count rate characteristics
  • 4.6 Time-of-flight resolution
  • 4.7 Image quality and quantitative accuracy of radioactive source activity concentration
  • 5 Accompanying document
  • 5.1 General Rule
  • 5.2 Design Parameters and Configuration
  • 5.3 Spatial resolution
  • 5.4 Sensitivity
  • 5.5 Scattering fraction
  • 5.6 Count Rate Performance
  • 5.7 Time-of-flight resolution
  • 5.8 Image quality and quantitative accuracy of radioactive source activity concentration
  • Appendix A (Informative) NEMANU2-2018
  • A.1 Definitions and Symbols
  • A.2 General Rule
  • A.3 Spatial resolution
  • A.4 Scattering fraction, count loss, and coincidence
  • A.5 Sensitivity
  • A.6 Accuracy. Counting loss and accidental coincidence count correction
  • A.7 Image quality, accuracy of attenuation correction and scattering correction
  • A.8 Time-of-flight resolution
  • References

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".

Drafting.

This document is Part 1 of GB/T 18988, "Performance and Test Rules for Radionuclide Imaging Equipment". GB/T 18988 has been...

The following sections were published.

---Part 1: Positron Emission Tomography Apparatus;

---Part 2: Planar, Whole-body, Tomographic Gamma Cameras this document replaces GB/T 18988.1-2013 "Performance and Test Rules for Radionuclide Imaging Equipment - Part 1: Positron Emissions".

Compared with GB/T 18988.1-2013, the main technical changes in "Radio Tomography Imaging Devices" are as follows, except for structural adjustments and editorial modifications.

a) Some content in the "Terms and Definitions" section has been changed (see Chapter 3, Chapter 2 of the 2013 edition);

b) The methodology, analysis, and reporting of "spatial resolution" have been changed (see 4.2, 3.1 in the 2013 edition);

c) The methodology, analysis, and reporting of "Tomographic Sensitivity" have been modified (see 4.3, 3.3 in the 2013 edition);

d) The methodology, analysis, and reporting of the "scattering fraction" have been changed (see 4.4, 3.6 of the 2013 edition);

e) The methodology, analysis, and reporting of "PET count rate characteristics" have been changed (see 4.5, 3.5 in the 2013 edition);

f) Added "time-of-flight resolution" (see 4.6);

g) Combine "Restoration Factor" (see 3.2 in the 2013 edition) and "Attenuation Correction" (see 3.7 in the 2013 edition) into "Image Quality and Magnification".

The accuracy of quantitative determination of source activity concentration was improved (see 4.7), and the methods, analysis, and reporting were modified.

h) "Uniformity" has been removed (see 3.4 in the 2013 edition);

i) The contents of "Supplementary Documents" have been changed (see Chapter 5, Chapter 4 of the 2013 edition).

This document is modified to adopt IEC 61675-1:2022 "Radionoid Imaging Apparatus - Performance and Test Rules - Part 1: Positron Emissions".

"Radio-tomographic imaging device".

This document has undergone the following structural adjustments compared to IEC 61675-1:2022.

---Appendix A has been added;

---Versions 4.7.4.2 and 4.7.5.5 have been deleted, and 4.7.4.1 has been changed to 4.7.4 in this file.

The technical differences between this document and IEC 61675-1:2022, and the reasons therefor, are as follows.

---The content regarding PET/CT image registration (see 4.7.4.2 and 4.7.5.5 of IEC 61675-1:2022) has been removed to align with the standard.

Use range.

The following editorial changes have been made to this document.

---To facilitate users' understanding and use of the IEC and NEMA series standards for positron emission tomography (PET) devices the document includes an informative appendix, Appendix A, which contains NEMANU2-2018, "Performance of Positron Emission Tomography (PET) Devices".

test".

Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.

This document was proposed by the National Medical Products Administration.

This document is under the jurisdiction of the National Technical Committee on Standardization of Medical Electrical Appliances (SAC/TC10).

Introduction

GB/T 18988, "Performance and Test Rules for Radionuclide Imaging Equipment", is divided into two parts.

---Part 1: Positron Emission Tomography (PET) Apparatus. The purpose is to describe the experimental methods for evaluating the performance of PET systems.

Law and accompanying documents.

---Part 2: Planar, Whole-Body, Tomographic Gamma Cameras. The purpose is to describe gamma cameras and single-photon emission computed tomography (SEP) imaging techniques.

Test methods and accompanying documentation for SPECT (Spectral Parametric Electron Device) performance.

This document is Part 1, describing how positron emission tomography (PET) devices detect the annihilation of positron-emitting radionuclides using coincidence detection.

radiation.

This document modifies and adopts IEC 61675-1:2022, and incorporates NEMA standard publication NU2-2018 "Positron Emission Tomography Apparatus".

Performance testing is included as Appendix A. Due to differences in testing requirements and methods between IEC and NEMA standards, it is recommended that the standard be...

Prospective users should use either method in its entirety, without crossing them over.

Performance and testing rules for radionuclide imaging equipment Part 1: Positron Emission Tomography Apparatus

1 Scope

This document specifies the test methods and accompanying documentation for the performance of positron emission tomography (PET) devices.

This document applies to positron emission tomography (PET) devices.

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.

For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.

This document.

(defined terms)

Note. GB/T 17857-1999 Medical Radiology Terminology (IEC 60788:1984, eqv)

3 Terms and Definitions

The terms and definitions defined in IEC TR60788:2004 and the following terms and definitions apply to this document.

Tomography

X-ray imaging of one or more layers inside an object.

[Source. IEC TR60788:2004, rm-41-15] 3.1.1 an imaging method for representing the spatial distribution of radionuclides contained on a specified two-dimensional slice passing through an object.

3.1.1.1

projection

Integrating along the direction of the projection beam with respect to the physical properties of a determined image transforms a three-dimensional object into a two-dimensional image, or transforms a two-dimensional object...

The volume is transformed into its one-dimensional image.

Note. This process is mathematically represented as a line integral along the projection direction (along the response line), and is called the Radon-transform.

3.1.1.2

projection beam

The projection beam determines the smallest possible volume of the image, within which the physical properties of the image are determined and integrated during the measurement process.

Note 1.The shape of the projection beam is limited by spatial resolution in all three spatial dimensions.

Note 2.The projection beam is mostly long and thin, cylindrical or conical in shape. In positron emission tomography (PET) imaging devices, it operates in a coincidence mode.

The sensitive volume between the two detector units.

3.1.1.3

projection angle

The angle used when measuring or acquiring a projection.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 54 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 18988.1-2025

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
54 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 18988.1-2025

$915.00