Valid

GB/T 20013.3-2015Nuclear medicine instrumentation -- Routine tests -- Part 3: Positron emission tomograph (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for GB/T 20013.3-2015 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Recommended

Issue date

December 10, 2015

Implementation date

July 1, 2017

Scope

GB/T 20013.3-2015 (Nuclear medicine instrumentation -- Routine tests -- Part 3: Positron emission tomograph) is available as an English-translated PDF.

GB/T 20013.3-2015 — This Part of GB/T 20013.3 is valid for POSITRON EMISSION TOMOGRAPHS utilizing stationary or moving detectors in a circular arrangement. This Part is not valid for SPECT-systems operated in coincidence mode.

In the framework of QUALITY CONTROL, this Part describes test methods suitable for the purpose of routine testing. Methods used for acceptance testing are described in GB/T 18988.1-2003.

Found what you need?

Document preview — GB/T 20013.3-2015

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C 53

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Normative references...5
  • 3 Terms and definitions...5
  • 4 Test methods...9
  • 5 Frequency of ROUTINE TESTS...11
  • Bibliography...12
  • Index of defined terms...13

Foreword

GB/T 20013 Nuclear medicine instrumentation - Routine tests consists of four

parts.

- Part 1. Radiation counting system;

- Part 2. Scintillation cameras and single photon emission computed

tomography imaging (SPECT);

- Part 3. Positron emission tomographs;

- Part 4. Radionuclide calibrator.

This Part is the third part of GB/T 20013.

This Part was drafted in accordance with the rules given in GB/T 1.1-2009.

This Part identically adopts IEC TR 61948-3.2005 Nuclear medicine

instrumentation - Routine tests - Part 3. Positron emission tomographs. For

easy use, this Part makes the following editorial modifications.

- deleted the foreword and introduction of IEC TR 61948-3.2005; added the

foreword of this Part;

- in Clause 2 "Normative references", added the introduction according to

the requirements of GB/T 1.1-2009;

- for other International standards referred in IEC TR 61948-3.2005, if they

have been transferred into China national standards, this Part used China

national standard reference number to replace the corresponding

International standard reference number;

- used decimal point "." to replace "," which was used as decimal point;

- used "this Standard" to replace "this International Standard".

Attention is drawn to the possibility that some of the elements of this document

may be the subject of patent rights. The issuing authority shall not be held

responsible for identifying any or all such patent rights.

This Part was proposed by State Food and Drug Administration.

This Part shall be under the jurisdiction of National Technical Committee on

Medical Electrical Equipment of Standardization Administration of China

(SAC/TC 10).

Nuclear medicine instrumentation - Routine tests -

Part 3. Positron emission tomographs

1 Scope

This Part of GB/T 20013.3 is valid for POSITRON EMISSION TOMOGRAPHS

utilizing stationary or moving detectors in a circular arrangement.

This Part is not valid for SPECT-systems operated in coincidence mode. In the

framework of QUALITY CONTROL, this Part describes test methods suitable

for the purpose of routine testing. Methods used for acceptance testing are

described in GB/T 18988.1-2003.

2 Normative references

The following referenced documents are indispensable for the application of

this document. For dated references, only the edition cited applies. For undated

references, the latest edition of the referenced document (including any

amendments) applies.

GB/T 18988.1-2003 Radionuclide imaging device - Characteristics and test

conditions - Part 1. Positron emission tomograph (IEC 61675-1.1998, IDT);

GB/T 20013.2-2005 Nuclear medicine instrumentation -Routine test - Part 2.

Scintillation cameras and single photon emission computed tomography

imaging (SPECT) (IEC 61948-2.2001, IDT)

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

NOTE A certain number of terms used in this document have been drawn from GB/T

17857, GB/T 18988.1 and GB/T 20013.1-2005 (see Index of defined terms).

3.1 quality control

part of the quality assurance in nuclear medicine including tests of instruments

with appropriate test methods

NOTE Includes both acceptance test and routine test.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 20013.3-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 20013.3-2015

$105.00