GB/T 20013.3-2015Nuclear medicine instrumentation -- Routine tests -- Part 3: Positron emission tomograph (English PDF)
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for GB/T 20013.3-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Recommended
Issue date
December 10, 2015
Implementation date
July 1, 2017
Scope
GB/T 20013.3-2015 (Nuclear medicine instrumentation -- Routine tests -- Part 3: Positron emission tomograph) is available as an English-translated PDF.
GB/T 20013.3-2015 — This Part of GB/T 20013.3 is valid for POSITRON EMISSION TOMOGRAPHS utilizing stationary or moving detectors in a circular arrangement. This Part is not valid for SPECT-systems operated in coincidence mode.
In the framework of QUALITY CONTROL, this Part describes test methods suitable for the purpose of routine testing. Methods used for acceptance testing are described in GB/T 18988.1-2003.
Found what you need?
Document preview — GB/T 20013.3-2015
National Standard of the People's Republic of China
- ICS
- 11.040.50
- Classification
- C 53
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Foreword...3
- 1 Scope...5
- 2 Normative references...5
- 3 Terms and definitions...5
- 4 Test methods...9
- 5 Frequency of ROUTINE TESTS...11
- Bibliography...12
- Index of defined terms...13
Foreword
GB/T 20013 Nuclear medicine instrumentation - Routine tests consists of four
parts.
- Part 1. Radiation counting system;
- Part 2. Scintillation cameras and single photon emission computed
tomography imaging (SPECT);
- Part 3. Positron emission tomographs;
- Part 4. Radionuclide calibrator.
This Part is the third part of GB/T 20013.
This Part was drafted in accordance with the rules given in GB/T 1.1-2009.
This Part identically adopts IEC TR 61948-3.2005 Nuclear medicine
instrumentation - Routine tests - Part 3. Positron emission tomographs. For
easy use, this Part makes the following editorial modifications.
- deleted the foreword and introduction of IEC TR 61948-3.2005; added the
foreword of this Part;
- in Clause 2 "Normative references", added the introduction according to
the requirements of GB/T 1.1-2009;
- for other International standards referred in IEC TR 61948-3.2005, if they
have been transferred into China national standards, this Part used China
national standard reference number to replace the corresponding
International standard reference number;
- used decimal point "." to replace "," which was used as decimal point;
- used "this Standard" to replace "this International Standard".
Attention is drawn to the possibility that some of the elements of this document
may be the subject of patent rights. The issuing authority shall not be held
responsible for identifying any or all such patent rights.
This Part was proposed by State Food and Drug Administration.
This Part shall be under the jurisdiction of National Technical Committee on
Medical Electrical Equipment of Standardization Administration of China
(SAC/TC 10).
Nuclear medicine instrumentation - Routine tests -
Part 3. Positron emission tomographs
1 Scope
This Part of GB/T 20013.3 is valid for POSITRON EMISSION TOMOGRAPHS
utilizing stationary or moving detectors in a circular arrangement.
This Part is not valid for SPECT-systems operated in coincidence mode. In the
framework of QUALITY CONTROL, this Part describes test methods suitable
for the purpose of routine testing. Methods used for acceptance testing are
described in GB/T 18988.1-2003.
2 Normative references
The following referenced documents are indispensable for the application of
this document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
GB/T 18988.1-2003 Radionuclide imaging device - Characteristics and test
conditions - Part 1. Positron emission tomograph (IEC 61675-1.1998, IDT);
GB/T 20013.2-2005 Nuclear medicine instrumentation -Routine test - Part 2.
Scintillation cameras and single photon emission computed tomography
imaging (SPECT) (IEC 61948-2.2001, IDT)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
NOTE A certain number of terms used in this document have been drawn from GB/T
17857, GB/T 18988.1 and GB/T 20013.1-2005 (see Index of defined terms).
3.1 quality control
part of the quality assurance in nuclear medicine including tests of instruments
with appropriate test methods
NOTE Includes both acceptance test and routine test.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 18988.1-2003Radionuclides imaging devices - Characteristics and test conditions - Part 1: Positron emission tomographs
- GB/T 20013.2-2005Nuclear medicine instrumentation - Routine tests - Part 2: Scintillation cameras and single photon emission computed tomography imaging
IEC 61675 · IEC 61948
How to Download GB/T 20013.3-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 20013.1-2025 — Nuclear medicine instrumentation - Routine tests - Part 1: Gamma radiation counting systems
GB/T 20013.2-2025 — Nuclear medicine instrumentation - Routine tests - Part 2: Scintillation cameras and single photon emission computed tomography imaging
GB/T 20013.4-2010 — Nuclear medicine instrumentation -- Routine tests -- Part 4: Radionuclide calibrator
Secure payment via Stripe
Payments accepted
GB/T 20013.3-2015
$105.00