YY/T 0729.4-2009Test methods for bonding properties of tissue adhesives - Part 4: Wound closure strength (English PDF)
组织粘合剂粘接性能试验方法 第4部分:伤口闭合强度
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0729.4-2009 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
June 16, 2009
Implementation date
December 1, 2010
Scope
YY/T 0729.4-2009 is the English-translated version of 组织粘合剂粘接性能试验方法 第4部分:伤口闭合强度.
YY/T 0729.4-2009 is the Chinese pharmaceutical industry standard that gives the method for measuring the wound closure strength of a tissue adhesive applied to relatively soft tissue.
It is the fourth part of the YY/T 0729 series and sets out the substrate and the incision made in it, the application of the adhesive across the wound, the loading and the force at which the closure fails; with a suitable substrate the method also serves the medical device manufacturer for quality control. Issued on 16 June 2009, it has applied since 1 December 2010.
Found what you need?
Document preview — YY/T 0729.4-2009
National Standard of the People's Republic of China
- Classification
- C 48
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
Foreword
YY/T 0729 "tissue adhesive bonding performance test method", it includes the following components.
--- Part 1. Lap - bearing shear tensile strength; Part --- Article 2. T- peel bearing tensile strength;
--- Part 3. Tensile strength;
--- Part 4. wound closure strength. This section YY/T Section 40729 of.
The partial modification using ASTM F2458-05 "Standard Test Method for tissue adhesives and sealants wound closure strength", and ASTM F2458-05 no technical difference.
Appendix A to this part of the normative appendix, Appendix B is an informative annex.
Introduction
Surgery for bonding living tissue materials and equipment increasingly used for sutures and staples play a supporting role in all kinds of surgery, Or used to replace these devices. Depending on the patient's specific circumstances, the nature and size of the force is also very different. All applications Material involving varying degrees of mechanical force applied affordability. Thus, the mechanical properties and adhesion properties of the material is unique to comment Price their applicability important parameters. In addition, given the mechanical properties of the adhesive can be used to evaluate whether the product is consistent in quality control, Which also can be used to evaluate the adhesive prior to use is affected by various surface treatments.
Application Category tissue adhesion complex instruments. Even in a given application (the procedure itself may vary in different parts of the body And clinical purposes vary), if you do not analyze, do not understand its application, adhesive properties and clinical phenomenon alone a wound closure Strength test results also suitable for determining the allowable design stresses.
Test methods may be used in this section gives comparative adhesive bonding process or sensitivity to environmental changes and fatigue, but for this ratio It must be compared with caution, because of different adhesives for different conditions may show different responses.
This test method has not been established with the results of actual human living tissue adhesion performance correlation.
1 Scope
This section YY/T 0729 include a method for protecting a relatively soft tissue attachment tissue adhesive wound closure strength. through By selecting suitable substrate, this part can be used for tissue adhesive medical device manufacturers in quality control.
2 Normative references
The following documents contain provisions which, through reference YY/T 0729 and become part of the provisions of this section. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage the agreement on this section Whether the parties can study the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
Inspection and correction tension and (or) pressure testing machine force measuring system. GB/T 16825.1 of static uniaxial testing machines - Part 1 Associate (GB/T 16825.1-2008, ISO 7500-1:1999, IDT)
3 Terms and Definitions
The following terms and definitions apply YY/T 0729 to the present section.
3.1 Wound closure device
All use as a medical device to help the wound edges together or soft tissue healing material.
3.2 Sealant
In order to prevent leakage of body fluids having a suitable surface coating agent adhesive strength.
3.3 Internal adhesive strength
3.4 Tissue adhesive/substrate interface strength
3.5 Internal adhesive bonding damage
3.6 Adhesive/substrate bonding damage
3.7 Tissue destruction substrate
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 0729.4-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16825.1-2002 — Verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Verification and calibration of the force-measuring system
GB/T 16825.1-2008 — Verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Verification and calibration of the force-measuring system
GB/T 16825.1-2022 — Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of the force-measuring system
YY/T 0729.4-2009