Scope
YY/T 0729.2-2009 is the English-translated version of 组织粘合剂粘接性能试验方法 第2部分:T-剥离拉伸承载强度.
YY/T 0729.2-2009 is the Chinese pharmaceutical industry standard that gives the T-peel test under tensile loading for the bonding properties of a tissue adhesive or sealant on soft tissue.
It is the second part of the YY/T 0729 series and provides a comparable measure of the adhesive strength, setting out the substrates, the bonded area, the peeling and the calculation of the peel strength; with a suitable substrate the method also serves the manufacturer for quality control. Issued on 16 June 2009, it has applied since 1 December 2010.
Found what you need?
Document preview — YY/T 0729.2-2009
National Standard of the People's Republic of China
- ICS
- 11.120.20
- Classification
- C 48
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Instrument
Foreword
YY/T 0729 "tissue adhesive bonding performance test method", it includes the following components.
--- Part 1. Lap - bearing shear tensile strength; Part --- Article 2. T- peel bearing tensile strength;
--- Part 3. Tensile strength;
--- Part 4. wound closure strength. This section YY/T Section 20729 of.
The partial modification using ASTM F2256-05 "Standard Test Method for strength T- peel tissue adhesive tensile bearer", and ASTM F2256-05 no technical difference.
Appendix A to this part of the normative appendix, Appendix B is an informative annex.
Introduction
Surgery for bonding living tissue materials and equipment increasingly used for sutures and staples play a supporting role in all kinds of surgery, Or used to replace these devices. Depending on the patient's specific circumstances, the nature and size of the force is also very different. All applications Material involving varying degrees of mechanical force applied affordability. Thus, the mechanical properties and adhesion properties of the material is unique to comment Price organizational suitability important parameters. In addition, given the mechanical properties of the adhesive can be used to evaluate whether the product is consistent in quality control, Which also can be used to evaluate the adhesive prior to use is affected by various surface treatments.
Application Category tissue adhesion complex instruments. Even in a given application (surgery), if without analysis of the binder Do not understand the performance alone a T- peel test result is unsuitable for determining the allowable design stresses.
Susceptibility test methods given in this section can be used to compare changes or adhesive bonding process to fatigue or the environment, but this ratio We must hold a relatively cautious because of different adhesives for different conditions may show different responses.
1 Scope
YY/T test method specified in this part of the organization for 0729 is expected to be bonded tissue adhesive or sealant on the soft tissue Adhesive strength provide comparable means. The method of selecting suitable substrate, this section can be used in the manufacture of tissue adhesive in quality control.
2 Normative references
The following documents contain provisions which, through reference YY/T 0729 and become part of the provisions of this section. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage the agreement on this section Whether the parties can study the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
Inspection and correction tension and (or) pressure testing machine force measuring system. GB/T 16825.1 of static uniaxial testing machines - Part 1 Associate (GB/T 16825.1-2008, ISO 7500-1:1999, IDT)
3 Terms and Definitions
The following terms and definitions apply YY/T 0729 to the present section.
3.1 Adherend
The method used in this section indicates that the term should be adhered such a size and physical properties, their adhesion to any corner less than 90 ° No cracking or rupture of the opening.
3.2 Tissue adhesive
This section refers to the expected tissue adhesives for closing wounds (surgery or trauma) or body fluid sealing compound or system leak.
3.3 Sealant
In order to prevent leakage of body fluids having a suitable surface coating agent adhesive strength.
3.4 Under
the conditions specified in this section, the gradual separation of the average load per unit width required for two specimens flexibility of being bonded.
4 Instrument
4.1 Testing Machine
4.1.1 fixing mechanism, with a fixed or stationary chuck mechanism.
4.1.2 moving mechanism, with the other movable chuck mechanism.
4.1.3 chuck to be sandwiched between the sample testing machine fixing mechanism and moving mechanism may be stationary, but also self-adjusting type.
4.1.3.1 Fixed chuck. rigid fixing mechanism and moving mechanism connected to the tester, when using this type of chuck, should pay special attention To ensure that the sample is inserted, and ensure the long axis of the sample by stretching direction coincides with the centerline of the collet assembly when clamped.
4.1.3.2 Automatic centering chuck. fixed mechanism and the moving mechanism in such a way to connect to the test machine, that is, once a load is applied, two Who would free the pair, so that the long axis of the sample with the tensile direction by the collet assembly centerline consistent. Samples can be realized in the tensile direction
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 0729.2-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16825.1-2002 — Verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Verification and calibration of the force-measuring system
GB/T 16825.1-2008 — Verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Verification and calibration of the force-measuring system
GB/T 16825.1-2022 — Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of the force-measuring system
YY/T 0729.2-2009
$135.00