YY/T 0729.3-2009Test methods for bonding properties of tissue adhesives - Part 3: Tension strength (English PDF)

组织粘合剂粘接性能试验方法 第3部分:拉伸强度

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0729.3-2009 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

June 16, 2009

Implementation date

December 1, 2010

Scope

YY/T 0729.3-2009 is the English-translated version of 组织粘合剂粘接性能试验方法 第3部分:拉伸强度.

YY/T 0729.3-2009 is the Chinese pharmaceutical industry standard that gives the tension test for the bonding properties of a tissue adhesive or sealant on soft tissue, the load being applied normal to the bonded surface.

It is the third part of the YY/T 0729 series and provides a comparable measure of the adhesive strength, setting out the substrates, the bonded area, the loading and the calculation of the tensile strength; with a suitable substrate the method also serves the manufacturer for quality control. Issued on 16 June 2009, it has applied since 1 December 2010.

Found what you need?

Document preview — YY/T 0729.3-2009

National Standard of the People's Republic of China

ICS
11.120.20
Classification
C 48

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Instrument

Foreword

YY/T 0729 "tissue adhesive bonding performance test method", it includes the following components.

--- Part 1. Lap - bearing shear tensile strength; Part --- Article 2. T- peel bearing tensile strength;

--- Part 3. Tensile strength;

--- Part 4. wound closure strength. This section YY/T Section 30729 of.

The partial modification using ASTM F2258-05 "tissue adhesive tensile strength of standard test methods", and no ASTM F2258-05 Technical differences.

Appendix A to this part of the normative appendix, Appendix B is an informative annex.

Introduction

Use, the scope and effectiveness of the binder in many clinical literature has a detailed report. Whether it is used as a binder, a hemostatic agent, secret Sealant, or a pharmaceutical carrier or growth factors, adhesives in the medical field in the increasingly widespread application. There are several factors for the medical organization Critical to the success and effectiveness of the adhesive. They are.

1) appropriate organizational bonding strength;

2) histocompatibility;

3) When used in vivo acceptable biodegradable;

4) accessibility;

5) ease of use;

6) costs.

Medical adhesive is widely used in various types of tissue. Applications range from fixed tissue outside the body to be applied to similar Two opposite surfaces or dissimilar. Biological or chemical composition of the binder determines its chemical properties, other mechanical factors, such as the use of an adhesive Or the amount of use will also affect the adhesive properties. Obviously, the amount of medical adhesive strength of the adhesive and the suitability of the adhesive concerned. open Made a constant, reproducible and comparable evaluation standard test method is very important. Since the adhesive is actually used in living tissue, Test is best to use easily-accessible surface of the test organisms.

Data generated from a standardized test method may differ from the in vivo situation. However, test results can be valuable for the adhesive properties Information, and to lay the conditions for future in vivo experiments.

Application Category tissue adhesion complex instruments. Even in a given application (surgery), if without analysis of the binder Do not understand the performance alone a tensile test result is unsuitable for determining the allowable design stresses.

Susceptibility test methods given in this section can be used to compare changes or adhesive bonding process to fatigue or the environment, but this ratio We must hold a relatively cautious because of different adhesives for different conditions may show different responses. Tissue adhesive bonding performance test method Part 3. Tensile Strength

1 Scope

YY/T test method specified in this part of the organization for 0729 is expected to be bonded tissue adhesive or sealant on the soft tissue Adhesive strength provide comparable means. The method of selecting suitable substrate, this section can be used in the manufacture of tissue adhesive in quality control.

2 Normative references

The following documents contain provisions which, through reference YY/T 0729 and become part of the provisions of this section. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage the agreement on this section Whether the parties can study the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

Inspection and correction tension and (or) pressure testing machine force measuring system. GB/T 16825.1 of static uniaxial testing machines - Part 1 Associate (GB/T 16825.1-2008, ISO 7500-1:1999, IDT)

3 Terms and Definitions

The following terms and definitions apply YY/T 0729 to the present section.

3.1 Tissue adhesive

This section refers to the expected tissue adhesives for closing wounds (surgery or trauma) or body fluid leaks or plugging compound system.

3.2 Sealant

In order to prevent leakage of body fluids having a suitable surface coating agent adhesive strength.

4 Instrument

4.1 Testing Machine

4.1.1 fixing mechanism, with a fixed or stationary chuck mechanism.

4.1.2 moving mechanism, with the other movable chuck mechanism.

4.1.3 chuck to be sandwiched between the sample testing machine fixing mechanism and moving mechanism may be stationary, but also self-adjusting Style.

4.1.3.1 Fixed chuck. rigid fixing mechanism and moving mechanism connected to the tester, when using this type of chuck, should pay special attention To ensure that the sample is inserted, and ensure the long axis of the sample by stretching direction coincides with the centerline of the collet assembly when clamped.

4.1.3.2 Automatic centering chuck. in such a way that the fixing mechanism and the moving mechanism connected to the tester, that is, once a load is applied, Both will be free to the stretching direction passing through the centerline of the collet assembly coincides with the long axis of the specimen. The sample may be implemented in the tensile direction The rotational motion of no, it will not slip or damage collet samples, self-adjusting jig can be a small amount of "not for the" conduct adjust.

4.1.4 driving mechanism, according to the provisions of 8.3 at a controlled uniform speed driven moving mechanism.

4.1.5 load indicator, when the sample held in the chuck a load indicating mechanism can display the total sample suffered tensile load. That Agencies, under specified test speed almost no inertia lag, load indication accuracy should not be less than ± 1% of indicated value. The test machine accuracy should be […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0729.3-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0729.3-2009

$135.00