Valid

YY/T 0729.1-2009Test methods for bonding properties of tissue adhesives - Part 1: Strength in lap-shear by tension loading (English PDF)

组织粘合剂粘接性能试验方法 第1部分:搭接-剪切拉伸承载强度

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0729.1-2009 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

June 16, 2009

Implementation date

December 1, 2010

Scope

YY/T 0729.1-2009 is the English-translated version of 组织粘合剂粘接性能试验方法 第1部分:搭接-剪切拉伸承载强度.

YY/T 0729.1-2009 is the Chinese pharmaceutical industry standard that gives the lap-shear test under tensile loading for the bonding properties of a tissue adhesive or sealant on soft tissue.

It is the first part of the YY/T 0729 series and provides a comparable measure of the adhesive strength, setting out the substrates and their preparation, the application of the adhesive, the loading and the calculation of the shear strength; with a suitable substrate the method also serves the manufacturer for quality control. Issued on 16 June 2009, it has applied since 1 December 2010.

Found what you need?

Document preview — YY/T 0729.1-2009

National Standard of the People's Republic of China

ICS
11.120.20
Classification
C 48

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Instrument

Foreword

YY/T 0729 "tissue adhesive bonding performance test method", it includes the following components.

--- Part 1. Lap - bearing shear tensile strength; Part --- Article 2. T- peel bearing tensile strength;

--- Part 3. Tensile strength;

--- Part 4. wound closure strength. This section YY/T Section 10729 of.

The partial modification using ASTM F2255-05 "tissue adhesive lap - shear strength Standard Test Method for Tensile bearer", and ASTM F2255-05 no technical difference.

Appendix A to this part of the normative appendix, Appendix B is an informative annex.

Introduction

Surgery for bonding living tissue materials and equipment increasingly used for sutures and staples play a supporting role in all kinds of surgery, Or used to replace these devices. Depending on the patient's specific circumstances, the nature and size of the force is also very different. All applications Material involving varying degrees of mechanical force applied affordability. Thus, the mechanical properties and adhesion properties of the material is unique to comment Price organizational suitability important parameters. In addition, given the mechanical properties of the adhesive can be used to evaluate whether the product is consistent in quality control, Which also can be used to evaluate the adhesive prior to use is affected by various surface treatments.

Application Category tissue adhesion complex instruments. Even in a given application (surgery), if without analysis of the binder Do not understand the performance alone a lap shear test result is unsuitable for determining the allowable design stresses.

Susceptibility test methods given in this section can be used to compare changes or adhesive bonding process to fatigue or the environment, but this ratio We must hold a relatively cautious because of different adhesives for different conditions may show different responses.

1 Scope

YY/T test method specified in this part of the organization for 0729 is expected to be bonded tissue adhesive or sealant on the soft tissue Adhesive strength provide comparable means. The method of selecting suitable substrate, this part can be used for tissue adhesives manufacturing quality control.

2 Normative references

The following documents contain provisions which, through reference YY/T 0729 and become part of the provisions of this section. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage the agreement on this section Whether the parties can study the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

Inspection and correction tension and (or) pressure testing machine force measuring system. GB/T 16825.1 of static uniaxial testing machines - Part 1 Associate (GB/T 16825.1-2008, ISO 7500-1:2004, IDT)

3 Terms and Definitions

The following terms and definitions apply YY/T 0729 to the present section.

3.1 Tissue adhesive

This section refers to the expected tissue adhesives for closing wounds (surgery or trauma) or body fluid leaks or plugging compound system.

3.2 Sealant

In order to prevent leakage of body fluids having a suitable surface coating agent adhesive strength.

3.3 Under

the conditions specified in this section, measured per unit of gradual separation of the desired bonding area when the two adherends bonded Average Load in MPa units.

4 Instrument

4.1 Testing Machine

4.1.1 fixing mechanism, with a fixed or stationary chuck mechanism.

4.1.2 moving mechanism, with the other movable chuck mechanism.

4.1.3 chuck to be sandwiched between the sample testing machine fixing mechanism and moving mechanism may be stationary, but also self-adjusting Style.

4.1.3.1 Fixed chuck. rigid fixing mechanism and moving mechanism connected to the tester, when using this type of chuck, should pay special attention To ensure that the sample is inserted, and ensure the long axis of the sample by stretching direction coincides with the centerline of the collet assembly when clamped.

4.1.3.2 Automatic centering chuck. in such a way that the fixing mechanism and the moving mechanism connected to the tester, that is, once a load is applied, Both will be free to the stretching direction passing through the centerline of the collet assembly coincides with the long axis of the specimen. The sample may be implemented in the tensile direction

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0729.1-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0729.1-2009

$165.00