YY/T 0590.2-2010Medical electrical equipment—Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency—Detectors used in mammography (English PDF)

医用电气设备 数字X射线成像装置特性 第1-2部分:量子探测效率的测定 乳腺X射线摄影用探测器

Preview PDF

This is a limited preview

Buy now to download the full PDF (18 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0590.2-2010 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

December 27, 2010

Implementation date

June 1, 2012

Scope

YY/T 0590.2-2010 is the English-translated version of 医用电气设备 数字X射线成像装置特性 第1-2部分:量子探测效率的测定 乳腺X射线摄影用探测器.

YY/T 0590.2-2010 is the Chinese pharmaceutical industry standard that fixes the method for determining the detective quantum efficiency of a digital X-ray imaging device, as a function of the air kerma and of the spatial frequency, under the conditions of medical use the manufacturer states, for the detectors used in mammography.

It is part 1-2 of the YY/T 0590 series and is addressed to manufacturers and to equipped test laboratories. Issued on 27 December 2010, it applies from 1 June 2012.

Found what you need?

Document preview — YY/T 0590.2-2010

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C 43

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions Requirement
  • 3
  • 4.1 Operating Conditions
  • 4.2 X-ray equipment
  • 4.3 Radiation quality
  • 4.4 Experimental Devices
  • 4.5 geometry
  • 5 of 8 unprocessed data correction
  • 6 Determination of the quantum detection efficiency of
  • 6.1 DQE (u, v) of the definition and formula
  • 6.28 parameters for evaluation
  • 6.3 determine different parameters of the image
  • 7 Declaration of Conformity
  • 8 accuracy
  • Appendix A (normative) Hysteresis is determined
  • Annex B (informative) Calculation of input noise power spectrum
  • References

Foreword

YY/T 0590 "Medical electrical equipment - Characteristics of digital X-ray imaging apparatus" is divided into the following sections.

--- YY/T 0590.1 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1. detective quantum efficiency Measurement;

--- YY/T 0590.2 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2. detective quantum efficiency measurement Given breast X-ray photography detectors;

--- YY/T 0590.3 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-3. detective quantum efficiency measurement Given the dynamic photographic detectors. This section YY/T Section 20590 of.

This section equivalent conversion IEC 62220-1-2:2007 "Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2. amount Sub-detection efficiency measured with detectors of breast X-ray photography. " And editorial changes as follows.

--- Remove the IEC foreword;

--- Table 2 under the original standard line comment "Context SNR2in calculations are given in Appendix C" to "SNR2in background letter computing Information is given in Appendix B... " This part of the National Technical Committee of Standardization for medical appliances medical X-ray equipment and utensils Standardization Technical Committee (SAC/TC10 / SC1) centralized.

This part mainly drafted by. Space Star Space Applications Limited, Liaoning Medical Device Control, Shanghai Hua nuclear medical line Child Instruments.

Introduction

Digital X-ray imaging apparatus is becoming widely used in medical diagnostics, and gradually replace the conventional screen film system and mold

Prepared by the X-ray image intensifier television system. Therefore, it is necessary to define the description of digital X-ray imaging device-specific parameters and imaging performance standard Normalized measurement procedures used.

A growing consensus in the scientific community's view that the detective quantum efficiency (DQE) is a description of X-ray imaging device imaging performance most suitable parameters number. DQE describe the imaging device from the radiation field to maintain the ability to output digital image data signal to noise ratio. Since the X-ray imaging, The radiation field of noise and air kerma levels are closely related, DQE values can also be considered a description of a given digital X-ray Efficiency dose-ray imaging apparatus.

Note: Although DQE has been widely used to describe the performance of the imaging device, but the relationship between the physical parameters and hide observed between the performance has not yet fully Clear.

DQE is already widely used by the manufacturer to characterize the performance of its digital X-ray imaging devices. DQE specification also made a number of management Institutions (eg FDA) as a recognized program. There is no standard specification measurement conditions or measurement procedures, resulting in data from different sources Not comparable.

Therefore, the development of this part of the format to standardize measurement procedures and digital X-ray imaging devices detective quantum efficiency of the declaration of conformity.

In the DQE calculation method recommended in this section, the system response is to assume that all the energy is equal attenuation measured. [5]

The development of this part of manufacturers, users, distributors and regulatory agencies are beneficial. It is a series of standards related to three of the second section.

Part 1. suitable for X-ray photography, not including breast X-ray photography and fluoroscopy; This section, namely Part 1-2. suitable for breast X-ray photography; Part 1-3. suitable for dynamic imaging detector.

These standards can be considered a description of digital X-ray imaging device-related parameters YY/T 0590 series of standards first section.

1 Scope

YY/T 0590 provisions of this section under the conditions of use specified by the manufacturer of medical work, as an air kerma and spatial frequency Method for measuring the digital X-ray imaging equipment detective quantum efficiency function. This section is intended user and equipment manufacturers Sophisticated testing laboratory.

This section applies to the breast X-ray photography imaging digital X-ray imaging equipment, such as, but not limited to.

System, scanning system (based on CCD or photon counter) based indirect flat panel detector. This section does not apply to.

--- For ordinary dental X-ray photography or photography digital X-ray imaging equipment;

--- CT;

--- Devices for dynamic imaging (obtain a series of images, such as fluoroscopy or cardiac imaging).

Note: The reason does not include the above device, since a number of very important parameters they contain different from the breast X-ray photography (for example, the quality of the wiring harness, bit geometry Position, time-dependent, etc.). The other part of the technical parameters of the series standards (YY/T 0590.1 and IEC 62220-1-3) conducted It has been described as a description of other parameters of the project, such as processing speed and contrast in IEC and ISO standards.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB 9706.24 Medical electrical equipment - Part 2-45. mammographic X - ray equipment and mammographic stereotactic device security Full-specific requirements (IEC 60601-2-45, IDT)

GB/T 20224-2006 digital camera exposure index, ISO speed ratings, standard output sensitivity, and recommended exposure index does Set (ISO /DIS12232.2004, IDT)

YY/T 0063 with diagnostic X-ray tube assemblies focus feature (YY/T 0063-2007, IEC 60336:2005, IDT)

YY/T 0590.1-2005 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1. detective quantum efficiency (YY/T 0590.1-2005, IDT)

IEC 61267:2005 with diagnostic X-ray equipment with radiation characteristic measurement conditions IEC TR60788 Definition Medical electrical equipment assembly

3 Terms and Definitions

IEC 60788 define the following terms and definitions apply to this document.

3.1 Conversion function

Different doses of radiation exposure, digital X-ray imaging apparatus of the original image with a large area of the pixel average value per unit area of the detector plane The radiation dose Q (the number of photons per unit area) of the corresponding curve.

Note 1. Q is measured backscattered remove air kerma, multiplied by the value calculated in Table 2 of 4 obtained.

Note 2. Many calibration laboratories, such as the National Institute of Metrology, Calibration for measuring air kerma dosimeters.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0590.2-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
18 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0590.2-2010

$285.00