Valid

YY/T 0590.3-2011Medical electrical equipment—Characteristics of digital X-ray imaging devices - Part 1-3: Determination of the detective quantum efficiency—Detectors used in dynamic imaging (English PDF)

医用电气设备 数字X射线成像装置特性 第1-3部分:量子探测效率的测定 动态成像用探测器

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0590.3-2011 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

December 31, 2011

Implementation date

June 1, 2013

Scope

YY/T 0590.3-2011 is the English-translated version of 医用电气设备 数字X射线成像装置特性 第1-3部分:量子探测效率的测定 动态成像用探测器.

YY/T 0590.3-2011 is the Chinese standard "Medical electrical equipment—Characteristics of digital X-ray imaging devices - Part 1-3: Determination of the detective quantum efficiency—Detectors used in dynamic imaging".

Its scope clause reads: YY/T 0590 This section specifies the use under medical conditions specified by the manufacturer working to release the kinetic energy of air ratio and spatial frequency Determination of the detective quantum efficiency of digital X-ray imaging apparatus function.

Expected users of this section is the manufacturer and well-equipped test laboratory. This section limits for dynamic imaging of digital X-ray imaging apparatus, such as, but not limited to, directly or indirectly, based on flat panel detector system.

This should not be part of YY/T 0590 is applied based on the X-ray image intensifier digital system. Note 1.

The reason why not is based on the phenomenon of low frequency drop and vignetting and geometric distortion phenomenon appears to consider in these devices, these phenomena may be serious Limit measuring method described in this section applicability.

YY/T 0590 This section does not apply to. --- Use of digital X-ray imaging apparatus mammography or dental photography; --- Computer tomography equipment; and --- Patient scan imaging X-ray systems; Note 2.

Does not include the above-described means, because they contain a lot different than for dynamic imaging very important parameters (for example, radiation quality, geometry, time Dependence, etc.).

Some of these parameters in other parts (YY/T 0590.1 and YY/T 0590.2) has been specified. Its clauses include terms and definitions.

Found what you need?

Document preview — YY/T 0590.3-2011

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C 43

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3 4.1 Operating Conditions
  • 4.2 X-ray equipment
  • 4.3 quality of the radiation
  • 4.4 Experimental Devices
  • 4.5 geometry
  • 4.6.1 General Conditions
  • 4.6.3 lag effect
  • 4.6.4 To obtain the conversion function of irradiation
  • 4.6.5 Irradiation for measuring noise power spectrum and the lagged effects of
  • 4.6.6 radiation beam in irradiated test devices
  • 4.6.7 Overview of all necessary irradiated
  • 5 9 unprocessed data correction
  • 6 Determination of the quantum detection efficiency of
  • 6.1 DQE (u, v) and the definition of formula
  • 6.2 10 parameters for evaluation
  • 11 6.3.1 Data linearization
  • 6.3.3 Determination of the modulation transfer function (MTF) of
  • 8 Accuracy
  • Annex B (informative) Calculation of input noise power spectrum
  • References

1 Scope

YY/T 0590 This section specifies the use under medical conditions specified by the manufacturer working to release the kinetic energy of air ratio and spatial frequency

Determination of the detective quantum efficiency of digital X-ray imaging apparatus function. Expected users of this section is the manufacturer and well-equipped test laboratory.

This section limits for dynamic imaging of digital X-ray imaging apparatus, such as, but not limited to, directly or indirectly, based on flat panel detector system.

This should not be part of YY/T 0590 is applied based on the X-ray image intensifier digital system.

Note 1. The reason why not is based on the phenomenon of low frequency drop and vignetting and geometric distortion phenomenon appears to consider in these devices, these phenomena may be serious

Limit measuring method described in this section applicability.

YY/T 0590 This section does not apply to.

--- Use of digital X-ray imaging apparatus mammography or dental photography;

--- Computer tomography equipment; and

--- Patient scan imaging X-ray systems;

Note 2. Does not include the above-described means, because they contain a lot different than for dynamic imaging very important parameters (for example, radiation quality, geometry, time

Dependence, etc.). Some of these parameters in other parts (YY/T 0590.1 and YY/T 0590.2) has been specified.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

YY/T 0063 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal (YY/T 0063-2007, IEC 60336.

2005, IDT)

YY/T 0481-20042) medical diagnostic X-ray equipment with radiation characteristic measurement conditions (IEC 61267.1994, IDT)

2) Although the IEC 61267 2nd edition (2005) has been released, but in order to make the IEC 62220 series of standards conformance, to the first edition (IEC 61267.

1994) is also a special reservation throughout this standard.

ISO 12232.1998 Determination of the electronic still photographic images from the camera's ISO speed (Photography-Electronicstil- picturecameras-DeterminationofISO speed)

IEC TR60788.2004 Medical electrical equipment defined in the glossary (Medicalelectricalequipment-Glossary ofdefinedterms)

3 Terms and Definitions

IEC 60788 define the following terms and definitions apply to this document.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0590.3-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0590.3-2011

$345.00