YY/T 1307-2024Medical digital X-ray image detector used in mammography (English PDF)
医用乳腺数字化X射线摄影用探测器
Open the YY/T 1307-2024 preview as PDF
This is a limited preview
Buy now to download the full PDF (22 pages)
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
July 8, 2024
Implementation date
July 20, 2025
Scope
YY/T 1307-2024 is the English-translated version of 医用乳腺数字化X射线摄影用探测器.
YY/T 1307 is the product standard for the digital detector used in mammography. Mammography asks more of a detector than any other radiographic application: it has to resolve microcalcifications a few tenths of a millimetre across while distinguishing soft tissue densities that differ barely at all, and it has to do so at a dose low enough to screen healthy women repeatedly. Spatial resolution, detective quantum efficiency, contrast response and defective pixel behaviour are therefore not general characteristics but the properties on which a cancer is seen or missed. The 2024 edition takes effect on 20 July 2025. For a manufacturer or an importer of mammography detectors, or a system integrator specifying one for the Chinese market, this is the standard the type testing follows.
Document preview — YY/T 1307-2024
National Standard of the People's Republic of China
- ICS
- 44.10.50
- Classification
- C43
- Replacing
- YY/T 1307-2016
Issued by: National Medical Products Administration
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and Definitions1
- 4 Classification and composition2
- 5 Requirement3
- 16 Appendix D (Informative) Test Device18
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part
1.Structure and drafting rules for standardization documents" Drafting. This document replaces YY/T 1307-2016 "Detectors for Medical Digital Mammography" and is consistent with YY/T 1307-2016. In addition to structural adjustments and editorial changes, the main technical changes are as follows:
a) Added "Calibration", "Center Axis", "Original Bright Field Image", "Original Dark Field Image", "Noise Equivalent Dose", "Frame Rate", "Exposure Window" 9 terms and definitions (see 3.1, 3.2, 3.3, 3.4, 3.5, 3.10, 3.11, 3.12) and 3.13);
b) Changed the definition of "linear dynamic range" (see 3.6,
3.2 of the.2016 edition);
c) The definition of "blind zone" has been changed (see 3.7,
3.3 of the.2016 edition);
d) Added "Classification" (see 4.1);
e) Added "noise equivalent dose" (see 5.4) and "noise equivalent dose" test method (see 6.4);
f) Deleted the "dose linear range" (see
5.4 of the.2016 edition) and the "dose linear range" test method (see 6.4);
g) Changed the "Linear Dynamic Range" (see 5.6,
5.5 of the.2016 version) and the "Linear Dynamic Range" test method (see 6.6, Version 6.5);
h) Changed the expression of "spatial resolution" (see 5.7,
1 Scope
YY/T 1307 is the product standard for the digital detector used in mammography. Mammography asks more of a detector than any other radiographic application: it has to resolve microcalcifications a few tenths of a millimetre across while distinguishing soft tissue densities that differ barely at all, and it has to do so at a dose low enough to screen healthy women repeatedly. Spatial resolution, detective quantum efficiency, contrast response and defective pixel behaviour are therefore not general characteristics but the properties on which a cancer is seen or missed. The 2024 edition takes effect on 20 July 2025. For a manufacturer or an importer of mammography detectors, or a system integrator specifying one for the Chinese market, this is the standard the type testing follows.
This document specifies the classification, composition and requirements of detectors for medical mammography (hereinafter referred to as detectors), and describes the corresponding test method. This document applies to detectors used in mammography equipment with single or multiple exposure imaging capabilities, including but not limited to amorphous Silicon detector, amorphous selenium detector, CCD (charge coupled device) detector, CMOS (complementary metal oxide semiconductor) detector, IGZO (Indium Gallium Zinc Oxide) detectors, photon counting detectors, etc. This document does not apply to.
--- Detectors for general photography and detectors for dental photography;
--- Detectors for computed tomography;
---Detector for dynamic imaging.
2 Normative references
The contents of the following documents constitute essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document.
GB 9706.1 Medical electrical equipment Part
3 Terms and definitions
The terms and definitions defined in YY/T 0590.2-2010, GB/T 10149-1988, YY/T 0481-2016 and the following apply in this document.
3.1 Calibration The detector performs necessary operations to make the image meet the evaluation requirements. These processes should be linear and independent of the image. Examples. background correction, gain correction, and bad pixel correction, etc.
3.2 Central axis A straight line perpendicular to the incident plane and passing through the center of the incident field.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 9706.1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
- YY 9706.102Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and tests
GB/T 10149-1988 · YY/T 0291 · YY/T 0481-2016 · YY/T 0590.2-2010
Editions of YY/T 1307
| Edition | Title | Revision | Status |
|---|---|---|---|
| YY/T 1307-2024 | Medical digital X-ray image detector used in mammography | current edition | Current |
| YY/T 1307-2016 | Medical digital X-ray image detector used in mammography | previous edition | In force until 2025-07-20 |
This page sells the current edition, YY/T 1307-2024. Earlier editions are listed for reference only.
How to Buy YY/T 1307-2024
- 1Add to cart. Click the "Buy YY/T 1307-2024" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 9706.1-2020 — Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
YY 9706.102-2021 — Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and tests
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
Secure payment via Stripe
Payments accepted
YY/T 1307-2024
$335.00