YY/T 0449-2018Ultrasonic Doppler fetal monitor (English PDF)

超声多普勒胎儿监护仪

Preview PDF

This is a limited preview

Buy now to download the full PDF (24 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0449-2018 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

November 12, 2018

Implementation date

November 1, 2019

Scope

YY/T 0449-2018 is the English-translated version of 超声多普勒胎儿监护仪.

YY/T 0449-2018 is the Chinese pharmaceutical industry standard for the ultrasonic Doppler fetal monitor, the cardiotocograph that follows the fetus through labour and warns when something goes wrong.

It gives the terms and definitions, the requirements, the test methods and the inspection rules, covering the fetal heart rate measurement and its accuracy and resolution, the uterine activity channel, the acoustic output, the alarms and their limits, the recorder and the display, and the electrical safety.

It applies to monitors working on the continuous wave or pulsed Doppler principle. Issued on 12 November 2018, it has applied since 1 November 2019.

Found what you need?

Document preview — YY/T 0449-2018

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C 41
Replacing
YY 0449-2009

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Requirements

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard replaces YY 0449-2009 "Ultrasonic Doppler fetal monitor", compared with YY 0449-2009, except for editorial changes The main technical changes are as follows.

--- Modified the definition of ultrasound Doppler fetal monitor (see 3.1, 3.1 of the 2009 edition);

--- Removed the content of the product category (see Chapter 4 of the 2009 edition);

--- Increased the temperature drift indicator of the contraction pressure value (see 4.6);

--- Modified the requirements for the storage record function (see 4.7, see 5.6 of the 2009 version).

The documents of our country that have a consistent correspondence with the international documents referenced by the standard norms are as follows.

GB-9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1:1988, IDT);

--- GB 9706.9-2008 Medical electrical equipment - Part 2-37. Particular requirements for safety of ultrasonic diagnostic and monitoring equipment (IEC 60601-2-37:2001, IDT);

--- YY 0709-2009 Medical electrical equipment - Part 1-8. General requirements for safety - Parallel standard. General requirements, medical Testing and guidance for alarm systems in gas and medical electrical systems (IEC 60601-1-8:2003, IDT).

Some elements of this standard may involve patents. The issuing organization of this standard does not assume responsibility for identifying these patents.

1 Scope

This standard specifies the terms and definitions, requirements, test methods and inspection rules for ultrasound Doppler fetal monitors.

This standard applies to ultrasound Doppler fetal monitor (hereinafter referred to as "instrument"), which uses continuous wave or pulse wave ultrasound Doppler Principle, continuous monitoring of the fetus during the perinatal period, and timely provide alarm information when an abnormality occurs.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB 9706.1 Medical electrical equipment - Part 1. General requirements for safety

GB 9706.9 Medical electrical equipment - Part 2-37. Particular requirements for safety of medical ultrasound diagnostic and monitoring equipment

GB/T 14710 Medical electrical requirements and test methods

YY 0709 Medical electrical equipment - Part 1-8. Safety general requirements. Parallel standard. General requirements, medical electrical equipment and medical Testing and guidance for alarm systems in electrical systems

YY/T 1142 Medical Ultrasound Equipment and Probe Frequency Characteristics Test Method

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 A device that continuously monitors the fetus during the perinatal period and provides alarm information in the event of an abnormality. The host, the ultrasound probe, and the palace

Compressed pressure sensor and other sensors connected to it, using ultrasonic Doppler principle to detect fetal heart rate, with monitoring and storage Fetal heart rate, contraction pressure, and other parameters.

4 Requirements

4.1 Ultrasonic operating frequency

The deviation of the ultrasonic operating frequency fW from the nominal frequency should be no more than ±10%.

4.2 Fetal heart rate measurement and display range

The measurement and display range of fetal heart rate should be no narrower than 65 times/min~210 times/min.

4.3 Fetal heart rate measurement error

The error in fetal heart rate measurement should be no more than ± 2 times/min.

4.4 Alarm function

The fetal heart rate alarm should meet the requirements specified in YY 0709, and the alarm state delay should not exceed 30s.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of YY/T 0449

EditionTitleRevisionStatus
YY/T 0449-2018Ultrasonic Doppler fetal monitorcurrent editionCurrent
YY 0449-2009Ultrasonic Doppler fetal monitorprevious editionSuperseded

This page sells the current edition, YY/T 0449-2018. Earlier editions are listed for reference only.

How to Download YY/T 0449-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
24 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0449-2018

$145.00