QC/T 943-2013Test method for lead and cadmium in automotive materials (English PDF)
汽车材料中铅、镉的检测方法
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for QC/T 943-2013 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
October 17, 2013
Implementation date
March 1, 2014
Scope
QC/T 943-2013 is the English-translated version of 汽车材料中铅、镉的检测方法.
QC/T 943-2013 gives the test methods for measuring lead and cadmium content in automotive materials. X-ray fluorescence spectrometry serves for screening, judging against screening values whether a more accurate determination is needed.
Photoelectric direct reading spectrometry quantifies both elements in steel, copper and copper alloys, and aluminium and aluminium alloys, with repeatability limits for the results.
For other cases, metal, polymer, coating or rubber samples are digested and measured by atomic absorption, ICP atomic emission or ICP mass spectrometry, with duplicate determinations that may not differ by more than 10% of their mean.
Results are rounded to GB/T 8170 and reported with the sample description and any abnormal observations. Issued on 17 October 2013, it has applied since 1 March 2014.
Found what you need?
Document preview — QC/T 943-2013
National Standard of the People's Republic of China
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword6
- 1 Scope8
- 2 Normative references8
- 3 X-ray fluorescence spectrometry9
- 4 Measure the lead and cadmium in the materials of steel, copper and spectrometry11
- 5 Atomic absorption spectrometry, inductive coupling plasma atomic spectrometry - measure lead and cadmium14
- 6 Test report19
1 Scope
This Standard specifies the test method of lead and cadmium content in automobiles materials. "X-ray Fluorescence Spectrometry" applies to the screening and rapid determination of lead and cadmium content in automobiles materials.
"Photoelectric Direct Reading Spectrometry for the Determination of Lead, Cadmium in Steel, Copper and Copper Alloys, Aluminum and Aluminum-Alloys" applies to quantitative detection of lead and cadmium content of steel, copper and copper alloys, aluminum and aluminum alloy rods or aluminum alloy bulks in automobiles materials.
"Methods of atomic absorption spectrometry, inductively coupled plasma atomic emission spectroscopy, or inductively coupled plasma mass spectrometry for the determination of lead, cadmium content in automobiles materials" applies to the quantitative detection of lead and cadmium content in automobiles materials.
2 Normative references
The articles contained in the following documents have become part of this Standard when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this Standard.
GB/T 602 Chemical reagent -- Preparations of standard solutions for impurity
GB/T 4336-2002 Standard test method for spark discharge atomic emission spectrometric analysis of carbon and low-Alloy steel (routine method)
GB/T 7999-2007 Optical emission spectrometric analysis method of aluminum and aluminum alloys
GB/T 8170 Rules of rounding off for numerical values & expression and judgement of limiting values
GB/T 20066 Steel and iron -- Sampling and preparation of samples for the determination of chemical composition
GB/T 30512-2014 Requirements for prohibited substances on automobiles
GB/Z 21277-2007 Rapid screening of lead mercury chromium cadmium and bromine of regulated substances in electrical and electronic equipment-X-ray fluorescence spectrometry
YS/T 482-2005 Methods for analysis of copper and copper alloys - The atomic emission spectrometry
IEC 62321:2008 Ed.1.0 Electrotechnical products - Determination of levels of six regulated substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers)
3 X-ray fluorescence spectrometry
3.1 Principle
Place the prepared samples in X-ray fluorescence spectrophotometer sample chamber.
According to the selected analytical model, conduct X-ray fluorescence spectroscopy analysis for the lead and cadmium content in the samples. According to the screening values, judge if the lead and cadmium content is qualified in the samples, and if it is required for further accurate determination.
3.2 Reagents and materials
3.3 Instruments and equipment
3.3.4 Tableting machine. Working pressure is not less than 20Mpa.
3.3.1 X-ray fluorescence spectrophotometer
3.3.2 Cutting machine
3.3.3 Crushing equipment. Pulverizer, grinder
3.4 Sample preparation
3.4.1 Principle of sample preparation.
3.4.2 Sample preparation method
3.4.2.1 Solid samples. Homogeneous samples may be determined directly by the X-ray fluorescence spectrophotometer. The sample size must meet the requirements of X-ray fluorescence spectrophotometer. In case of the sample is too big, it shall be processed into a smaller size of ±10mm - ± 40mm, and with a smooth surface.
3.4.2.2 Fluid sample. PIPETTE a certain volume of liquid sample into the special plastic cup. USE the polyester film of 6mm in thickness to support the bottom of sample cup.
COVER the cup with an aperture plastic cap. The thickness of the sample is not less than 15mm.
3.5 Analytical steps
3.5.1 Instrument preparation
TURN on the instrument in accordance with the operational specifications of the instrument. PREHEAT the instrument to be stable.
3.5.2 Analyze the spectral line
For X-ray fluorescence spectrometry, the analysis spectral line is recommended to select lead; Cadmium.
3.5.3 Drawing of working curve
SELECT different content's lead and cadmium standard substances that match the tested sample matrix and have no less than 5 points. MEASURE the fluorescence intensity of lead and cadmium in the standard substances in accordance with the measurement conditions of X-ray fluorescence spectrometer. DRAW the working curve in accordance with the given standard values by the standard substances and the measured fluorescence intensity values by the spectrometer.
3.6 Analysis of result
3.6.1 Calculation of result
According to the selected analysis mode, CALCULATE the lead and cadmium content in the sample, based on the measured spectral line intensity of elements lead and cadmium.
4 Measure the lead and cadmium in the materials of steel, copper and copper alloy, aluminum and aluminum alloy - photoelectric direct reading spectrometry
4 Measure the lead and cadmium in the materials of steel, copper and spectrometry
4.1 Determination range of measuring the lead and cadmium in the materials of steel, copper and copper alloy, aluminum and aluminum alloy by photoelectric direct reading spectrometry is shown in Table 2.
4.2 Principle
After the processed sample is excited by light source, the radiated light enters into the beam splitting system through the entrance slit to disperse into spectrum. CONDUCT the photovoltaic conversion for the selected spectral lines by the photo-translating system and measuring system. And measure the spectral line intensity. MEASURE the mass fraction of elements lead and cadmium, according to the working curve made by corresponding standard substances (standard samples).
4.3 Auxiliary materials
4.3.1 Standard substance (standard sample). It shall be a national or recognized authoritative standard substance (standard sample). In principle, the standard substance (standard sample) shall be basically consistent with the chemical composition and metallurgical casting process of the analytical sample.
4.3.2 Control sample. The standard sample that has the exact constant value and has a similar matrix and organization structure with the sample to be tested.
4.4 Instruments and equipment
4.4.2 Sample processing equipment. Grinding machine (sandpaper millstone, abrasive band grinding machine), lathe or milling machine.
4.4.1 Photoelectric direct reading spectrometer
4.5 Sample preparation
Sample shall be prepared according to the requirements of GB/T 20066. The surface of the taken sample shall ensure that it can excite 2 points without overlapping. And it can completely cover the excitation hole, so as to ensure that the excitation chamber does not leak gas.
4.6 Analytical steps
4.6.1 TURN on the instrument in accordance with the requirements of instrument specifications. PREHEAT the instrument to be stable.
4.6.2 Before analysis, firstly USE a sample for continuous excitation and good reproducibility. CONFIRM the instrument is in the best working condition.
4.6.3 According to the material type of sample, SELECT the corresponding appropriate standard substances (standard samples).
4.6.4 According to the type of sample and alloy designation, SELECT the analytical procedure.
4.6.5 Analysis of drift correction of curve. According to the type of sample to be tested, SELECT the control sample. The control sample is continuously excited and has good reproducibility. STORE the mean value, so as to confirm whether the analytical curve is drifted.
4.6.6 Sample analysis
The sample shall be excited to measure at least twice. The mean value shall be used as analysis results when the data is stable. The content is expressed by mass fraction (%).
Rounding off value is in accordance with GB / T 8170.
4.7 Precision
4.7.1 Repeatability
For the measured values of 11 independent test results obtained under repeatability conditions, within the given measured range as follows, their relative standard deviation shall not exceed the provisions of Table 3.
5 Atomic absorption spectrometry, inductive coupling plasma atomic emission spectroscopy or inductively coupled plasma mass spectrometry - measure lead and cadmium
5 Atomic absorption spectrometry, inductive coupling plasma atomic spectrometry - measure lead and cadmium
5.1 Principle
WEIGH appropriate amount of sample. USE dissolved acid to completely digest the sample. PREPARE homogeneous solution. USE atomic absorption spectrometry, inductive coupling plasma atomic emission spectroscopy, or inductively coupled plasma mass spectrometry to measure lead and cadmium concentration in the solution.
5.2 Reagents and materials
Unless otherwise specified, in analysis, only USE recognized analytical pure reagent and distilled water or deionized water or water with equivalent purity.
5.3 Instruments and equipment
5.4 Sample preparation
5.4.1 Metal material
The sample is processed to debris with a thickness not more than 1mm.
5.5 Analytical steps
5.5.1 Sample
WEIGH 0.10g -1.00g of specimen, accurate to 0.0001g.
5.5.2 Determination number of times
PERFORM twice independent determination. TAKE the average values.
5.5.3 Blank test
MAKE a blank test along with the specimen.
5.5.4 Determination
5.5.4.1 Preparing solution of metal material. PLACE the sample (5.5.1) in 250mL beaker.
ADD appropriate amount of dissolved acid to heat to dissolve. After the sample to be tested is completely dissolved, REMOVE it into 100mL volumetric flask. DILUTE to the scale with water and mix evenly.
5.5.4.2 Preparation of polymer solution. PLACE the specimen (5.5.1) into microwave digestion tank. Respectively ADD 5mL of concentrated nitric acid, 1.5mL of tetrafluoro boric acid solution and 1.5mL of hydrogen peroxide. For samples containing more siliceous, it is required to add 1mL of tetrafluoro borate solution. If the sample contains a large number of easily oxidized organic ingredients, it cannot add hydrogen peroxide. CLOSE the digestion tank.
5.5.4.4 Preparation of rubber solution.
5.5.4.3 Preparation of coating solution
5.5.4.5 Measurement of specimen solution. MEASURE the absorbency and intensity
values of the lead and cadmium in the blank test solution along with the specimen and the specimen solution WITH the atomic absorption spectrometer, inductive coupling plasma atomic emission spectrometer, and inductively coupled plasma mass spectrometry. And CHECK out the content of the lead and cadmium from the working curve.
5.5.5 Drawing of working curve
5.5.5.1 Preparation of standard solution working curve. According to the content of lead and cadmium, PREPARE the standard solutions not less than 5 points and with different concentration of lead and cadmium. If the sample matrix has interference on the measured elements, it can use matrix matching method to eliminate the interference. DILUTE with water to the scale. SHAKE evenly.
5.5.5.2 Preparation of working curve of standard substance. According to the material of the sample to be tested, CHOOSE the standard substances not less than 5 points and with different content of lead and cadmium. In accordance with the preparation method of analysis specimen, PREPARE standard substance solutions. DILUTE to the scale with water and mix evenly.
5.5.5.3 Measurement. ARRANGE the solutions of the standard solution working curve and the solutions of standard substance working curve, based on the sequence from low concentration to high concentration. MEASURE the absorbency or intensity value of the lead and cadmium WITH the atomic absorption spectrometer, inductive coupling plasma atomic emission spectrometer, and inductive coupling plasma mass spectrometer. TAKE mass of lead and cadmium as the abscissa; and absorbance and intensity value as the ordinate. DRAW the working curve.
5.6 Result calculation
According to Equation (1), CALULATE the mass fraction (%) of the lead and cadmium. The calculated result is rounded in accordance with GB/T 8170.
5.7 Precision
Under the repeatability conditions, the absolute difference value between the 2 independent determination results shall not exceed 10% of the arithmetic mean value.
6 Test report
The test report shall include the following contents.
a) Sample description, laboratories, test date and other information;
b) The degree of complying the provisions of this standard;
c) Test results and its expression;
d) Abnormal phenomena observed in the test process. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 602Chemical reagent - Preparation of standard solutions for impurity determination
- GB/T 4336-2002Carbon and low-alloy steel—Determination of multi-element contents—Spark discharge atomic emission spectrometric method (routine method)
- GB/T 7999-2007Photoelectric direct reading atomic emission spectrometric analysis of aluminium and aluminium alloys
- GB/T 8170Rules of rounding off for numerical values & expression and judgement of limiting values
- GB/T 20066Steel and iron -- Sampling and preparation of samples for the determination of chemical composition
- GB/T 30512-2014Requirements for prohibited substances on automobiles
IEC 62321:2008
Cited by
- GB/T 47246-2026Technical specification for the electronic functions of child restraint systems for power-driven vehicles
- GB/T 41006-2021General technical requirements for polyurethane synthetic leather used for vehicle
- QC/T 568-2019Specifications and bench test methods for automotive manual transmission assemblies
Similar standards
How to Download QC/T 943-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 20066-2006 — Steel and iron -- Sampling and preparation of samples for the determination of chemical composition
GB/T 30512-2014 — Requirements for prohibited substances on automobiles
GB/T 602-2026 — Chemical reagent - Preparation of standard solutions for impurity determination
Secure payment via Stripe
Payments accepted
QC/T 943-2013
$155.00