NB/T 32015-2013Technical Specification for Distributed Resources Connected to Distribution Network (English PDF)

分布式电源接入配电网技术规定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for NB/T 32015-2013 in 30 minutes.

Issued by

NEA

Level / Type

Industry · Recommended

Issue date

November 28, 2013

Implementation date

April 1, 2014

Scope

NB/T 32015-2013 is the English-translated version of 分布式电源接入配电网技术规定.

NB/T 32015-2013 sets the general principles and technical requirements for connecting distributed resources, meaning synchronous generators, induction generators and converter-based sources located close to users, to the distribution network at 35 kV and below.

It applies to new, rebuilt and expanded installations. Power quality clauses deal with harmonics, voltage deviation, unbalance, fluctuation and flicker, and call for class A power quality monitors at the point of common coupling, keeping at least one year of data.

The standard also defines the point of interconnection and islanding, and draws on quoted standards for relay protection, telecontrol and meter communication such as GB/T 14285, DL/T 634.5104 and DL/T 645. Issued on 28 November 2013, it has applied since 1 April 2014.

Found what you need?

Document preview — NB/T 32015-2013

National Standard of the People's Republic of China

ICS
27.160
Classification
F 12

Issued by: National Energy Administration of the People's Republic of China

Contents

  • 1 Scope
  • 2 Normative reference documents
  • 3 Terms and definitions
  • 4 Power quality

1 Scope

This standard specifies the general principles and technical requirements for distributed power supply access to the grid.

This standard applies to 30kV and below the voltage level access to the new grid, alteration and expansion of distributed power supply.

2 Normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. This is the latest version of the book, including all modifications.

GB 2894 Safety signs and guidelines for their use

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Distributed resources

Access 35kV and below the voltage level, located near the user, local consumption-based power, including synchronous generators, asynchronous generators, Converter and other types.

3.2 Converter

An electrical device for converting electrical power into electrical power for one or more forms suitable for use by a grid or a user. Including rectifiers, Inverters, AC converters and DC converters.

3.3 Converter-type power supply

Converter type power supply converter-type power supply All or part of the power supply connected to the grid through the converter.

Synchronous generator type power supply Asynchronous left motor type power supply Through the asynchronous generator directly connected to the power grid.

Point of interconnection For a distributed power supply with a booster station, it refers to the high voltage side bus or node of the booster station. For distributed power supplies without booster stations, refer to distributed Power output summary point. The definition of the dotted network can be found in Appendix A of this standard.

Public connection point of common coupling User access to the public grid connection.

Island islanding Including the load and power of some of the grid, from the main network after the separation from the state to continue to run alone. Isolated islands can be divided into unplanned islands and planned islands.

Note: Unplanned islands are unscheduled and unregulated. Planned islands are planned to occur in a planned control strategy.

4 Power quality

4.1 General requirements

4.1.1 The quality of the distributed power supply, in terms of harmonics, voltage deviation, voltage imbalance, voltage fluctuation and flicker, etc. Related national standards.

4.1.2 through the voltage level of the converter network type of distributed power supply should be installed at the public connection to meet GB/T 19862 Required level A power fil on-line monitoring device, power quality. n. monitoring historical data should be kept for at least one year.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download NB/T 32015-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

NB/T 32015-2013

$209.00