Valid

JJF 1591-2016Program of Pattern Evaluation of Coriolis Mass Flow Meters (English PDF)

Preview PDF

Also coversJJF1591-2016

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for JJF 1591-2016 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Level / Type

National · Mandatory

Issue date

November 25, 2016

Implementation date

May 25, 2017

Scope

JJF 1591-2016 (Program of Pattern Evaluation of Coriolis Mass Flow Meters) is available as an English-translated PDF.

JJF 1591-2016 is the Chinese standard "Program of Pattern Evaluation of Coriolis Mass Flow Meters". Its scope clause reads: This Program applies to the pattern evaluation of Coriolis mass flow meters (hereinafter referred to as flow meters).

Its clauses include terms; overview; requirements for legal management; measurement requirements; general technical requirements. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on 2016-11-25 and took effect on 2017-05-25.

Found what you need?

Document preview — JJF 1591-2016

National Standard of the People's Republic of China

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Contents

  • Introduction...5
  • 1 Scope...6
  • 2 Normative references...6
  • 3 Terms...7
  • 4 Overview...8
  • 5 Requirements for legal management...8
  • 5.1 Units of measurement...8
  • 5.2 Accuracy level...8
  • 5.3 Sealed structure...9
  • 5.4 Installation marks...9
  • 5.5 Technical documents to be submitted by the applicant...9
  • 5.6 Test prototypes to be submitted by the applicant...9
  • 6 Measurement requirements...10
  • 6.1 Maximum allowable error...10
  • 6.2 Repeatability...10
  • 6.3 Zero stability...10
  • 6.4 Pressure loss...10
  • 7 General technical requirements...10
  • 7.1 Accompany documents...10
  • 7.2 Appearance and nameplate...11
  • 7.3 Protection function...11
  • 7.4 Protective function...11
  • 7.5 Compressive strength...11
  • 7.6 Resistance to transportation and storage...11
  • 7.7 Electromagnetic compatibility performance...12
  • 7.8 Electrical safety performance test...13

1 Scope

This Program applies to the pattern evaluation of Coriolis mass flow meters (hereinafter referred to as flow meters).

2 Normative references

This Rules refers to the following documents.

JJG 1038-2008, Verification Regulation of Coriolis Mass Flow Meters

JJF 1001-2011, General Terms in Metrology and Their Definitions

JJF 1004-2004, Metrological Terms and Their Definitions for Flow Rate

JJF 1094-2002, Evaluation of the Characteristics of Measuring Instruments

GB/T 2423.1, Environmental testing for electric and electronic and electronic products -- Part 2.Test methods -- Tests A. Cold temperature (idt IEC 60068-2-1)

GB/T 2423.2, Environmental testing for electric and electronic products -- Part 2.

Test methods -- Tests B. Dry heat (idt IEC 60068-2-2)

GB/T 2423.3, Environmental testing for electric and electronic products -- Part 2.

Testing method test Cab. Damp heat steady state (idt IEC 60068-2-78)

GB/T 2423.10, Environmental testing -- Part 2.Test methods -- Test Fc. Vibration (sinusoidal) (idt IEC 60068-2-6)

GB 3836.1, Explosive atmospheres -- Part 1.Equipment -- General requirements

GB 3836.2, Explosive atmospheres -- Part 2.Equipment protection by flameproof enclosures "d"

GB 3836.3, Explosive atmospheres -- Part 3.Equipment protection by increased safety "e"

GB 3836.4, Explosive atmospheres -- Part 4.Equipment protection by intrinsic safety "i"

GB 4208, Degrees of Protection Provided by Enclosure (IP Code)

GB/T 13609, Sampling method of natural gas

GB/T 13610, Analysis of natural gas composition -- Gas chromatography

GB/T 17626.2, Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test (idt IEC 61000-4-2)

GB/T 17626.4, Electromagnetic compatibility -- Testing and measurement techniques -- Electrical fast transient/burst immunity test (idt IEC 61000-4-2)

GB/T 17626.5, Electromagnetic compatibility -- Testing and measurement techniques -- Surge immunity test (idt IEC 61000-4-5)

GB/T 17626.11, Electromagnetic compatibility -- Testing and measurement techniques -- Part 11.Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase (idt IEC 61000-

4-11)

GB/T 17747.2, Natural gas -- Calculation of compression factor -- Part 2.

Calculation using molar-composition analysis

GB 17820, Natural gas

GB/T 20728-2006, Measurement of fluid flow in closed conduits -- Guidance to the selection installation and use of Coriolis meters (idt ISO 10790.1999)

GB 50251, Design code for gas transmission pipeline engineering

SY/T 6659-2006, Measurement of Natural Gas by Coriolis Meter

For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies to this Rules.

3 Terms

In addition to the terms and definitions specified in JJF 1094 and JJF 1004, this Program also uses the following terms and definitions.

3.1 zero offset

Before zero adjustment, the instantaneous mass flow rate of the flow meter is measured when the medium inside the flow meter is stationary. This value can be reduced or eliminated by zero adjustment.

3.2 zero stability

After zero adjustment, when the medium inside the flowmeter is stationary, the instantaneous flow rate value of the zero offset is continuously read 30 times at uniform time intervals within 5 min. The average value of the absolute flow rate value each time is taken as the zero stability of the flowmeter.

3.3 pulse per unit (also known as k coefficient)

The number of pulses emitted by the flow meter when a unit mass of fluid passes through it.

3.4 calibration factor

The coefficients related to mass flow rate measurement are obtained through sensor calibration. This factor is unique to each sensor. It is incorporated into the transmitter to ensure the flow meter's metrological performance. Calibration factors are further divided into flow calibration factors and density calibration factors, each composed of one or more parameters.

4 Overview

A flow meter utilizes the Coriolis force generated when fluid flows within a vibrating tube to measure the fluid's mass flow rate, either directly or indirectly. A flow meter consists of a sensor and a transmitter. The sensor primarily comprises a vibrating tube and a drive component. The transmitter mainly consists of a measurement and output unit. It receives signals from the sensor and outputs or displays the mass flow rate measurement results as DC current, pulses, or digital signals.

5 Requirements for legal management

5.1 Units of measurement

Flow meters shall use legal units of measurement.

5.2 Accuracy level

The accuracy level of the flow meter and its corresponding maximum allowable error shall meet the requirements of Table 1.If the accuracy level is not listed in Table 1, its maximum allowable error shall still meet the principle of corresponding accuracy level and maximum allowable error in Table 1.

Table 1 -- Accuracy level of flow meter

5.3 Sealed structure

For flow meters that are not allowed to be adjusted by the user, protective measures shall be in place. Any human interference that can affect the accuracy of the flow meter will leave a mark on the flow meter.

5.4 Installation marks

The flow meter shall have a clear and permanent flow direction mark.

5.5 Technical documents to be submitted by the applicant

The applicant shall provide two copies of the following technical documents.

- Application for "Type Approval of Measuring Instruments", commissioned by the government's metrology administration department;

- Product standards;

- Prototype photos and product structure photos and descriptions;

- Assembly drawings, circuit diagrams, and a list of key components;

- Instruction manual;

- Test reports prepared by the manufacturer or technical institution;

- Measuring instruments operating in explosive atmospheres shall provide explosion-proof certificates.

Technical documentation shall be complete, accurate, scientific, and reasonable. If any significant defects or deficiencies are found, the documentation and prototype shall be returned to the applicant for correction.

5.6 Test prototypes to be submitted by the applicant

5.6.1 For applications for a single product, three sample units shall be provided for flow meters with a diameter less than 100 mm. One sample unit shall be provided for flow meters with a diameter of 100 mm or more.

Accuracy level

Maximum allowable error /%

5.6.2 For applications submitted by product series, at least one-third of the

representative specifications from each product series shall be randomly selected. The number of test samples provided for each specification shall be based on the principle of a single product.

5.6.3 If the product uses key materials or components that are nominally the same but can affect the product's metrological performance, different prototypes shall be provided.

6 Measurement requirements

6.1 Maximum allowable error

The maximum allowable error of the flow meter shall comply with the provisions of

Clause 5.2.

6.2 Repeatability

The repeatability of the flow meter shall not exceed half of the absolute value of the allowable error specified in the corresponding accuracy level in Clause 5.2.

6.3 Zero stability

The ratio of the zero stability of the flow meter to the minimum flow rate shall not exceed 1/2 of the absolute value of the allowable error corresponding to the accuracy level.

6.4 Pressure loss

The pressure loss of the flow meter shall not exceed the specifications in the product instruction manual or product standard.

7 General technical requirements

7.1 Accompany documents

The flow meter shall have an instruction manual. The instruction manual shall provide the flow meter name, model, measuring medium, working pressure range, working temperature range, nominal diameter, flow range, zero stability, accuracy level, power supply voltage, flow sensor material and weight, signal output method, manufacturer, explosion-proof rating and explosion-proof certificate number (for flammable and explosive environments), protection level, installation conditions and methods, and instructions for using the protection functions.

7.2 Appearance and nameplate

7.2.1 Appearance

Newly manufactured flow meters shall have a good appearance. The surface coating shall be uniform in color and free from burrs, scratches, cracks, rust, mildew, and peeling. Sealing surfaces shall be smooth and undamaged. Welded joints shall be smooth and clean, free from incomplete welds or detachment. Flow meter connectors must be secure and reliable, and shall not loosen or detach due to vibration. The numbers, text, and symbols displayed on the flow meter shall be clear and neat. The flow meter buttons shall have a comfortable feel and not be sticky.

7.2.2 Nameplate

The flow meter shall have a nameplate. The nameplate shall indicate the name, model, serial number, K coefficient, calibration factor, measuring medium (gas, liquid), flow range (qmin ~ qmax), nominal diameter, accuracy level, maximum working pressure, power supply voltage, flow sensor material, manufacturer and manufacturing date, manufacturing instrument license mark and number, explosion-proof rating (for flammable and explosive environments), and protection class.

7.3 Protection function

Flow meters with protection features shall have protection functions for flow meter parameters (such as passwords). If parameters are modified, the modification traces shall be left and permanently saved.

7.4 Protective function

For flow meters used in different applications, the corresponding protection level requirements specified in GB 4208 shall be met, and a protection level certificate issued by a nationally recognized institution shall be obtained.

7.5 Compressive strength

The flow meter shall be able to withstand 1.5 times the maximum working pressure for

5 min, and shall show no leakage, no damage, and no seepage.

7.6 Resistance to transportation and storage

The flow meter shall have good resistance to transportation and storage.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

Referenced standards

Normative references

JJF 1004-2004 · JJF 1094-2002 · GB 3836.1 · GB 3836.2 · GB 3836.3 · GB 3836.4 · GB 4208 · GB/T 13609 · GB/T 17747.2 · SY/T 6659-2006

How to Download JJF 1591-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1591-2016

$370.00