HG 2227-2004Water treatment chemicals - Aluminium sulfate (English PDF)
水处理剂 硫酸铝
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for HG 2227-2004 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Mandatory
Issue date
December 14, 2004
Implementation date
June 1, 2005
Scope
HG 2227-2004 is the English-translated version of 水处理剂 硫酸铝.
HG 2227-2004 is the Chinese standard "Water treatment chemicals - Aluminium sulfate". Its scope clause reads: This Standard specifies the technical requirements, classification, test methods, inspection rules and marking, labelling and packaging of water treatment chemicals - aluminium sulfate.
This Standard applies to water treatment chemicals - aluminium sulfate (solid and solution) Molecular formula: Al 2(SO4) 3·xH2O Relative molecular mass [in terms of Al 2(SO4) 3]: 342.15 (based on 2 000 International Relative Atomic Masses). Its clauses include application scope; inspection rules.
Found what you need?
Document preview — HG 2227-2004
National Standard of the People's Republic of China
- Replacing
- HG 2227-1991
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword3
- 1 Application Scope4
- 2 Normative References4
- 3 Product Classification5
- 4 Technical Requirements5
- 5 Test Methods5
- 6 Inspection Rules20
- 7 Marking, Labelling and Packaging21
1 Application Scope
This Standard specifies the technical requirements, classification, test methods, inspection rules and marking, labelling and packaging of water treatment chemicals - aluminium sulfate.
This Standard applies to water treatment chemicals - aluminium sulfate (solid and solution)
Molecular formula: Al 2(SO4) 3·xH2O
Relative molecular mass [in terms of Al 2(SO4) 3]: 342.15 (based on 2 000 International
Relative Atomic Masses)
2 Normative References
The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who enter into an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies.
GB/T 191-2000, Packaging - Pictorial Marking for Handling of Goods
GB/T 601-2002, Chemical Reagent - Preparations of Standard Volumetric Solutions
GB/T 602-2002, Chemical Reagent - Preparations of Standard Solutions for
Impurity (neq ISO 6353-1:1982)
GB/T 603-2002, Chemical Reagent - Preparations of Reagent Solutions for Use in
Test Methods (neq ISO 6353-1:1982)
GB/T 610.1-1988, Chemical Reagent - General Method for the Determination of
Arsenic
GB/T 1250, Rules for Expression and Judgement of Limiting Values
GB/T 6678-1986, General Principles for Sampling Chemical Products
GB/T 6680, General Rules for Sampling Liquid Chemical Products
GB/T 6682-1992, Water for Analytical Laboratory Use - Specification and Test
Methods (neq ISO 3696:1987) […]
5.2.2.4 Ammonium hydroxide solution
1 + 3.
5.2.2.5 Acetic acid-sodium acetate buffer solution
pH = 4.5.
5.2.2.6 Ascorbic acid solution
20 g/l/
Weigh 10.0 g of ascorbic acid to dissolve in about 200 mL of water; add 0.20 g of dihydrogen disodium ethylenediaminetetraacetate and 8 mL of formic acid; use water to dilute to 500 mL; and mix up. Store in a brown bottle as standby with the period of
15 d.
5.2.2.7 Phenanthroline solution
2 g/l.
Dissolve 0.5 g of phenanthroline hydrochloric acid (monohydrate) (C12H9CLN2·H2O) in water and dilute to 100 mL.
Or dissolve 0.42 g of phenanthroline (monohydrate) (C 12H8N 2·H2O) in 100 mL of water containing 2 drops of hydrochloric acid.
The solution is stored in the dark; and it can be stored stably for one week.
5.2.2.8 Iron standard stock solution
1 mL contains 0.1 mg of Fe.
5.2.2.9 Iron standard solution
1 mL contains 0.01 mg of Fe.
Transfer 10 mL of iron standard stock solution into a 100 mL measuring flask; and dilute to the marked line. The solution shall be prepared immediately before use.
5.2.3 Apparatus and implements
Commonly-used laboratory instruments.
Spectrophotometer: carrying an absorption cell of an optical path 3 cm.
5.2.4 Plotting of calibration curve
Take successively, 0 (blank), 2.00 mL, 4.00 mL, 6.00 mL, 8.00 mL and 10.00 mL of iron standard solution into six 100 mL measuring flasks; add water up to about 40 mL; add
0.50 mL of sulfuric acid solution to adjust the pH to close to 2; add 3.0 mL of ascorbic acid solution, 10.0 mL of acetic acid-sodium acetate buffer solution and 5.0 mL of phenanthroline solution. Use water to dilute to the marked line; and shake up. Store for 15 min at room temperature; measure its absorbance by means of spectrophotometry using the reagent blank to set zero at the wavelength of 510 nm.
Plot the calibration curve making use of the absorbance measures as the ordinate and the corresponding iron content (mg) as the abscissa.
5.2.5 Analytical procedures
Transfer an appropriate volume (e.g. 2 ml) of test solution A and the corresponding volume of blank test solution respectively into a 100 mL measuring flask; add water to […]
5.6 Determination of lead content
5.6.1 Method summary
Use the electric heating atomic absorption spectrometry; and measure the absorbance at the wavelength of 283.3 nm.
5.6.2 Reagents and materials
5.6.2.1
Water, of grade 3 as specified in GB/T 6682.
5.6.2.2 Nitric acid solution
1 + 1.
5.6.2.3 Lead standard stock solution
1 mL contains 0.1 mg of Pb.
Weigh 0.100 g of lead (of mass fraction greater than 99.9%), accurate to the nearest
0.000 2 g; add 20 mL of nitric acid to dissolve; heat to get rid of nitric oxide; transfer into a 1 000 mL measuring flask after cooling; add water up to the marked line; and shake up.
5.6.2.4 Lead standard solution
1.00 mL contains 0.01 mg of Pb.
Transfer 10.00 mL of lead standard stock solution into a 1 000 mL measuring flask;
add 20 mL of nitric acid solution; add water up to the marked line; and shake up.
5.6.3 Apparatus
General laboratory instruments.
Electric heating atomic absorption spectrometer.
Hollow cathode lamp for lead.
5.6.4 Analytical procedures
5.6.4.1
Weigh about 10 g of liquid sample or 5 g of solid sample, accurate to 0.000 2 g. Put it into a 250 mL beaker; add 30 mL of water and 10 mL of nitric acid solution;
cover the watch glass to boil for about 1 min; transfer into a 1 000 mL measuring flask after cooling to room temperature; dilute to the marked line; and shake up. This is test solution B for the determination of Pb and Cd.
5.6.4.2
Transfer respectively 5.00 mL of test solution B to put into four 50 mL measuring flasks; add successively 0.00, 1.00 mL, 2.00 mL and 3.00 mL of lead standard solution; add water up to the marked line; and shake up. Use a micropipette to inject the prepared sample into the heating furnace; and measure its absorbance at […]
5.7.2.6 Ammonium hydroxide solution
1 + 3.
5.7.2.7 Ammoniacal washing solution
take 1 mL of ammonium hydroxide; add water
up to 100 mL; and add 5 mL of EDTA solution.
5.7.2.8
Potassium permanganate.
5.7.2.9 Hydroxylamine hydrochloride
200 g/l.
Take 20 g of hydroxylamine hydrochloride; and use water to dissolve up to 100 mL.
Transfer the solution into a 200 mL separating funnel; add 10 mL of diphenylthiocarbazone-carbon tetrachloride solution; and discard the carbon tetrachloride layer. Repeat the operation until the colour of diphenylthiocarbazone solution becomes the inherent green colour.
5.7.2.10 Urea solution
200 g/l.
Take 20 g of urea; use water to dissolve to 100 mL. Transfer the solution into a 200 mL separating funnel; add 10 mL of diphenylthiocarbazone-carbon tetrachloride solution;
shake up before allowing to stand; and discard the carbon tetrachloride layer. Repeat the operation until the colour of diphenylthiocarbazone solution becomes the inherent green colour.
5.7.2.11 Ethylenediaminetetraacetic acid disodium salt solution
38 g/l.
Take 3.8 g of ethylenediaminetetraacetic acid disodium salt (dihydrate); and use water to dissolve to 100 mL. Transfer the solution into a 200 mL separating funnel; add 10 mL of diphenylthiocarbazone-carbon tetrachloride solution; shake up before allowing to stand; and discard the carbon tetrachloride layer. Repeat the operation until the colour of diphenylthiocarbazone solution becomes the inherent green colour.
5.7.2.12 Refined carbon tetrachloride
add sulfuric acid about 5% of the volume of carbon tetrachloride into carbon tetrachloride before shaking up to mix up; and allow to stand before discarding the sulfuric acid layer. Repeat the operation until the sulfuric acid layer becomes colourless. Then use water to wash; add flaky calcium oxide before shaking up to mix up; distill carrying the flaky calcium oxide; and take the cut fraction of 77°C.
5.7.2.13 Diphenylthiocarbazone-carbon tetrachloride stock solution
0.1 g/l.
Take diphenylthiocarbazone into an agate mortar; and grind into powder. Take 100 mg from it; add 1 l of refined carbon tetrachloride; stir from time to time; and allow to stand for more than 24 h to fully dissolve diphenylthiocarbazone.
5.7.2.14
Diphenylthiocarbazone-carbon tetrachloride concentrated solution: 0.05 g/l.
Accurately measure 100.00 mL of diphenylthiocarbazone-carbon tetrachloride stock solution; pour it into a 200 mL measuring flask; add refined carbon tetrachloride up to the marked line.
5.8.4.2 Plotting of calibration curve
Transfer 0.00, 1.00 mL, 2.00 mL, 3.00 mL and 4.00 mL of chromium standard solution into 100 mL measuring flasks; use water to dilute to the marked line; and shake up.
The chromium contents of the standard series are 0.00, 0.10 mg, 0.20 mg, 0.30 mg and 0.40 mg; measure its absorbance at the wavelength of 357.9 nm under the optimum working conditions of the apparatus, using the blank to set zero.
5.8.4.3 Determination of sample
Under the equivalent instrument conditions to the calibration curve, measure its absorbance using the blank to set zero; and obtain the chromium content from the calibration curve.
5.8.5 Expression of analytical results
The chromium content W6, expressed with mass fraction, the value in %, is calculated in accordance with Formula (6):
where, m--the value of the mass of chromium obtained from the calibration curve, in mg;
m0--the value of the mass of sample, in g.
5.8.6 Tolerance
Take the arithmetic mean value of the results determined in parallel as the determination result. The absolute difference of the results determined in parallel shall not be greater than 0.000 1%.
5.9 Determination of cadmium content
5.9.1 Method summary
Use the atomic absorption spectrometric method; at the wavelength of 228.8 nm, use the air-acetylene flame to determine the absorbance of cadmium atom; and obtain the cadmium content.
5.9.6 Tolerance
Take the arithmetic mean value of the results determined in parallel as the determination result. The absolute difference of the results determined in parallel shall not be greater than 0.000 05%.
6 Inspection Rules
6.1
All indexes specified in this Standard are the type inspection items. Under the normal production conditions, type inspection shall be carried out at least once every three months. For the items including aluminum oxide, insoluble matter, pH and iron, inspection shall be carried out batch by batch.
6.2
Each batch of products shall not exceed 150 t.
6.3
The number of sampling units shall be as specified in GB/T 6678. When sampling solid products, first remove the material layer about 30 cm thick in the upper part of the packaging bag; use a sampling instrument to take not less than 100 g of sample from the centre of each bag; crush rapidly the sample taken to approximately less than
10 mm; mix up; and divide it into shares of not less than 500 g by quartering. The sampling for liquid products shall be as specified in GB/T 6680; take more than 500 mL of sample by inserting through the top inlet of storage tank, ship cabin and tank truck into the upper, middle and lower parts of the liquid layer, or from the material outlet in the first, middle and last stages; and mix up.
6.4
Water treatment chemicals-aluminium sulfate shall be inspected for product quality by the quality inspection department of the manufacturer in accordance with the test methods and inspection rules specified by this Standard; and the manufacturer shall ensure all products delivered are as specified in this Standard.
6.5
Each batch of products delivered shall be accompanied by quality specifications, indicating manufacturer name, product name, category, batch number, manufacturing date, net content, certificate of product quality in compliance with this Standard and a reference to this Standard.
6.6
The user shall be entitled to carry out quality inspection for the products received as specified in this Standard and verify whether the quality complies with this Standard.
6.7
Use the rounded-off value comparison method specified in GB/T 1250 to decide whether the inspection results comply with this Standard. If one items of the inspection results fails to comply with this Standard, take a double number of samples to conduct inspection once again; and if one item of inspection results fails to comply with this
Standard, then the batch of products are not acceptable.
6.8
In case of any dispute in the product quality between the supplier and the […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of HG 2227
| Edition | Title | Revision | Status |
|---|---|---|---|
| HG 2227-2004 | Water treatment chemicals - Aluminium sulfate | current edition | Current |
| HG 2227-1991 | Water treatment chemicals - Aluminium sulfate | previous edition | Superseded |
This page sells the current edition, HG 2227-2004. Earlier editions are listed for reference only.
How to Download HG 2227-2004
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
HG 20226-2015 — Code for construction and acceptance of tubular furnace installation works
HG 20202-2014 — Code for construction and acceptance of degreasing project
HG 20231-2014 — Code for project commissioning in chemical industry
HG 2227-2004
$125.00