Valid

GB/Z 43521-2023General guidelines for the design and analysis of ocean thermal energy conversion plant (English PDF)

海洋温差能转换电站设计和分析的一般指南

Preview PDF

This is a limited preview

Buy now to download the full PDF (31 pages)

Need quotation for your management?

Get a formal quotation for GB/Z 43521-2023 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 28, 2023

Implementation date

December 28, 2023

Scope

GB/Z 43521-2023 is the English-translated version of 海洋温差能转换电站设计和分析的一般指南.

GB/Z 43521-2023 is a Chinese national guidance document for designing and assessing ocean thermal energy conversion (OTEC) power plants, adopted with modifications from IEC TS 62600-20:2019.

It deals with site-specific and marine meteorological design parameters, cold and warm seawater systems, seawater discharge and plume analysis, working fluid and heat exchanger selection, platform type, mooring and positioning, power export and energy storage by hydrogen, ammonia, methanol or batteries.

Further clauses treat land-based and seabed-based plants, cold seawater pipe design, design and operation under risky conditions, transport and installation, commissioning, operation, inspection, maintenance and decommissioning.

It applies to land-based, seabed-based and floating systems, normally up to the point where the main export cable connects to the grid. Developers, engineers, financiers and regulators are its intended readers. It was issued on 28 December 2023.

Found what you need?

Document preview — GB/Z 43521-2023

National Standard of the People's Republic of China

ICS
27.180
Classification
F 14

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Abbreviations
  • 5 Site-specific parameters and marine meteorological design parameters
  • 5.1 Environmental factors
  • 5.2 Biological effects
  • 6 Floating Ocean Thermoelectric Energy Conversion Power Plant --- General Information and Guidelines (Closed Cycle, Deep Sea Water)
  • 6.1 Precautions for seawater
  • 6.2 Cold sea water system
  • 6.3 Warm seawater system
  • 6.4 Seawater discharge arrangements and plume analysis
  • 7 Process System
  • 7.1 Working fluid selection
  • 7.2 Heat exchanger selection
  • 7.3 Material Compatibility
  • 7.4 Risks and hazards in process systems
  • 8 Platform Type
  • 8.1 General
  • 8.2 Mooring and positioning
  • 9 Power output
  • 9.1 Overview
  • 9.2 Design considerations
  • 9.3 Platform equipment
  • 9.4 Power transmission system
  • 9.5 Land-based equipment
  • 10 Energy storage and transportation systems
  • 10.1 Overview
  • 10.2 Hydrogen
  • 10.3 Ammonia
  • 10.4 Methanol
  • 10.5 Battery storage
  • 11 Land-based and seabed-based ocean temperature difference energy conversion power stations
  • 11.1 General information and guidance
  • 11.2 Cold seawater pipe design
  • 12 Design and operation methods of ocean temperature difference energy conversion power station under risky conditions
  • 12.1 Risk Assessment
  • 12.2 Design under risky conditions
  • 12.3 Guidance on operation under risky conditions
  • 13 Transport and installation
  • 14 Trial operation and handover
  • 15 Operation, inspection and maintenance
  • 15.1 Overview
  • 15.2 Run
  • 15.3 Inspection and maintenance
  • 15.4 Hazards and Safety
  • 16 Retired
  • Appendix A (informative) Technical differences between this document and IEC TS62600-20:2019 and their reasons
  • Appendix B (informative) Potential uses and history of ocean temperature difference energy conversion B 2 Installation site

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1. Structure and Drafting Rules of Standardization Documents" Drafting.

This document is modified to adopt IEC TS62600-20:2019 "Ocean energy wave energy, tidal energy and other current energy conversion devices Chapter 20 Part. General Guidelines for Design and Analysis of Ocean Thermoelectric Energy Conversion (OTEC) Power Plants. The file type is adjusted from IEC technical specifications to my country's National standardization guiding technical document.

Compared with IEC TS62600-20:2019, there are many technical differences in this document. A list of these technical differences and their causes is attached. Record A. The following editorial changes have been made to this document.

---The name of the standard was changed to "General Guidelines for Design and Analysis of Ocean Thermoelectric Energy Conversion Power Plants".

Introduction

The ocean covers 70% of the earth's surface, and most of the solar energy entering the ocean is absorbed by the upper water within 100m.

Collected and retained in the form of heat energy. The heated surface seawater expands slightly and continues to absorb solar energy, causing the surface seawater in the tropics to Water temperature usually exceeds 25°C. The temperature of deep seawater is much lower. When the seawater depth is 800m~1000m, the temperature is generally 4°C~5°C, see Figure 1. This type of deep cold seawater is replenished from the polar regions through ocean thermohaline circulation. Take advantage of the gap between surface and deep seawater Temperature difference, a large amount of energy can be continuously obtained through Ocean Temperature Energy Conversion (OTEC).

In the tropics, the diurnal and annual changes in temperature differences between ocean water layers are small and predictable. OTEC power stations take advantage of this stable temperature difference.

It can continuously generate electricity. See Appendix B for other potential uses and history of ocean temperature difference energy. Since OTEC's process is relatively simple, it is It has a high capacity factor compared to most other forms of renewable energy. Capacity factor refers to the actual power generation within a period of time compared with the same time The ratio of the maximum possible power generation in the segment. The maximum power generation capacity of a specific equipment is assumed to be generated when it is operated continuously at rated power during the relevant time period. generated electricity. Compared with the continuous and low capacity factors of most renewable energy sources, OTEC power output has good reliability and Predictability.

0.1 OTEC working principle OTEC power stations use thermodynamic cycles to convert sustainable low-grade ocean thermal energy into electrical energy. The theoretical highest heat transfer efficiency is provided by card The Nolan cycle determines where the absolute ocean temperature is in Kelvin. When the heat source temperature is 27°C and the cold source temperature is 4°C, the Carnot cycle effect The rate is.

Tcold Thot 4 273.15 27 273.15=7.66% Assuming that the conversion process is completed by an ideal reversible heat engine, the efficiency can reach 7.66%. In practical applications, due to the heat transfer in the heat exchanger Temperature difference and other factors, the actual heat exchange is irreversible. When calculating the actual efficiency, such heat transfer losses as well as the turbine and power generation should be considered. the actual performance of the machine. Therefore, under the above seawater temperature conditions, the actual efficiency under non-ideal conditions is 3%~4%.

According to the degree of contact between the system working fluid and the outside air, OTEC power stations can be divided into. closed, open and mixed circulation systems.

Which type of circulation system should be determined based on local conditions such as power and fresh water needs.

0.2 Closed loop

The most basic cycle method of the closed OTEC system is the Rankine cycle. The main devices and processes of the closed Rankine cycle OTEC power plant are shown in Figure 2. The working fluid runs in the closed pipeline of the system. The working fluid pump sends the liquid working fluid into the evaporator. The working fluid absorbs the heat of warm seawater and vaporizes to produce high temperature.

The pressurized steam enters the turbine and drives the turbine to drive the generator; the exhaust gas at the outlet of the turbine enters the condenser and is condensed into liquid by cold seawater. liquid working medium Then it enters the working fluid pump to complete this cycle. Indexing serial number description. 1---Warm seawater pump; 2---Evaporator; 3---Turbine; 4---Generator; 5---Condenser; 6---cold sea water pump; 7---Liquid storage tank; 8---Working fluid pump.

Figure 2 Principle diagram of closed Rankine cycle ocean temperature difference energy conversion power station

Warm seawater transfers heat to the working fluid in the evaporator to boil it. The temperature of the warm seawater decreases, and the deep cold seawater absorbs the steam in the condenser.

The temperature rises after the heat released during condensation. Warm seawater provides 3% to 6% more heat than cold seawater. This difference is due to the Caused by flat work and energy lost due to friction.

Different working fluids have different fluid physical properties, such as ammonia (R717), difluoromethane (R32), 1,1,1,2-tetrafluoroethane (R134a), etc. for For a specific working fluid, its appropriate evaporation and condensation characteristics and thermal performance of the heat exchanger should be selected to obtain the best efficiency. in circulatory system Among them, the highest pressure occurs at the outlet of the working fluid pump, the lowest pressure occurs in the condenser, and the maximum pressure drop occurs in the turbine.

0.3 open cycle

The open cycle uses surface temperature seawater as the working fluid, which is converted into low-pressure steam in the evaporator, drives the turbine to do work, and is then discharged into the condenser.

Cooling circulation system. The process is that warm seawater enters a large evaporator with a vacuum degree of about 96%, part of which evaporates into low-pressure steam, and the rest Seawater provides the heat required for evaporation, and cooled, warm seawater is pumped out of the evaporator. Low-pressure steam drives the low-pressure turbine to operate, and then enters the true A condenser with an air density of about 98%. The steam is condensed into liquid and pumped out of the condenser. A continuously operating vacuum pump removes dissolved air and to maintain the vacuum within the system.

Open cycle OTEC can both generate electricity and produce fresh water by isolating steam from cold seawater in a large surface condenser.

The main difference between closed cycle and open cycle OTEC power plants is that the open cycle system uses a large vacuum chamber and an extremely large volume of low-pressure steam.

A steam turbine is used, while a closed cycle uses a heat exchanger, a smaller turbine and a working fluid pump. The schematic diagram of the open cycle OTEC system is shown in Figure 3. Indexing serial number description. 1---Warm seawater pump; 2---Flash evaporator; 3---Turbine; 4---Generator; 5---Condenser; 6---cold seawater pump; 7---Fresh water pump; 8---Warm seawater drainage pump.

Figure 3 Schematic diagram of the principle of an open cycle ocean temperature difference energy conversion power station

0.4 Mixed cycle

The hybrid cycle combines the characteristics of closed cycle and open cycle systems and can generate electricity and fresh water at the same time. The system uses multi-level cloth Heat exchangers, vacuum chambers and other components can extract more heat from warm and cold seawater. Schematic diagram of hybrid circulation OTEC system See Figure 4. Indexing serial number description. 1---Warm seawater pump; 2---Flash evaporator; 3---Fresh water pump; 4---Warm seawater drainage pump; 5---Evaporator; 6---Turbine;

7 ---Generator;

8 ---Condenser;

9 ---Liquid storage tank; 10---Working fluid pump; 11---Cold seawater pump.

Figure 4 Schematic diagram of the principle of a hybrid cycle ocean temperature difference energy conversion power station

1 Scope

This document establishes the general guidelines for the design evaluation of OTEC power plants. The purpose is to explain the OTEC power plants that can stably generate electricity under various conditions.

Design and evaluation requirements. The target audience is developers, engineers, banks, venture capital practitioners, entrepreneurs, financial institutions and regulatory agencies, etc.

This document applies to land-based (i:e. onshore), seabed-based (i:e. installed on the seabed nearshore) and floating OTEC systems. Scope of application of this document The enclosure usually ends at the connection point of the main power output cable to the grid.

This document is a general document, focusing on OTEC's unique or unique power generation equipment devices and components, especially those related to warm and cold seawater.

Equipment related to the water inlet part. The OTEC system is compatible with other types of power plants and floating oil and gas production vessels (such as floating production storage systems and floating liquid Common components between chemical and natural gas systems refer to established standards. This document lists relevant standards as applicable.

The main design process of floating, seabed-based or land-based OTEC systems is shown in Figure 5.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 31 pages — is available in the English PDF.

Similar standards

How to Download GB/Z 43521-2023

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
31 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 43521-2023