GB/Z 43280-2023Medical laboratories - Practical guidance for the estimation of measurement uncertainty (English PDF)

医学实验室 测量不确定度评定指南

Preview PDF

This is a limited preview

Buy now to download the full PDF (54 pages)

Need quotation for your management?

Get a formal quotation for GB/Z 43280-2023 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

November 27, 2023

Implementation date

November 27, 2023

Scope

GB/Z 43280-2023 is the English-translated version of 医学实验室 测量不确定度评定指南.

GB/Z 43280-2023 offers practical guidance to medical laboratories on estimating measurement uncertainty (MU), and is identical to ISO/TS 20914:2019.

Following the top-down approach of the GUM, it explains the concept of MU, maximum allowable MU, its sources, expression and reporting, then walks through the steps of evaluation: defining the measurand, measurement precision, changes in reagent and internal quality control lots, multiple measuring systems, end-user calibrator uncertainty, bias, re-evaluation, qualitative results based on numerical values and counting.

Worked examples cover the anion gap, glomerular filtration rate, white blood cell counts, albumin, the international normalized ratio, HIV-1 viral load, BCR-ABL1, rubella IgG and hepatitis B surface antigen.

It also applies to point-of-care testing, and advises that MU be supplied on request rather than routinely reported. It was issued on 27 November 2023.

Found what you need?

Document preview — GB/Z 43280-2023

National Standard of the People's Republic of China

ICS
11.100
Classification
C 30

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 symbols
  • 5 Measurement uncertainty for use in medical laboratories
  • 5.1 Concept of measurement uncertainty
  • 5.2 Maximum allowable measurement uncertainty
  • 5.3 Sources of measurement uncertainty
  • 5.4 Expression of measurement uncertainty
  • 5.5 Calculating Uncertainty Estimates Using Relative Standard Uncertainty
  • 5.6 Reporting measurement uncertainty
  • 6 Uncertainty evaluation steps of measured values
  • 6.1 Definition of measurand
  • 6.2 Measurement precision
  • 6.3 The impact of changes in batch numbers of reagents and indoor quality control materials on uncertainty assessment
  • 6.4 The laboratory uses multiple measurement systems for the same measured object
  • 6.5 Uncertainty of end-user calibration values (ucal)
  • 6.6 Measurement bias
  • 6.7 Overview of the evaluation process of measurement uncertainty
  • 6.8 Re-evaluation of measurement uncertainty
  • 6.9 Qualitative results based on numerical values
  • 6.10 Uncertainty in entity counting
  • 6.11 Limitations of measurement uncertainty assessment values
  • Appendix A (Informative) Examples of Evaluating Measurement Uncertainty A 1 Introduction

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1. Structure and Drafting Rules of Standardization Documents" Drafting.

This document is equivalent to ISO /T S20914.2019 "Guidelines for the Evaluation of Uncertainty in Measurement in Medical Laboratories". The file type is determined by ISO.

The technical specifications were adjusted into my country's national standardization guiding technical documents.

Introduction

In a global economy where patients and healthcare professionals are increasingly mobile within and between healthcare delivery systems, global healthcare Improvements in standardization and consistency of academic laboratory practices would benefit society. To help achieve the goals of medical laboratory standardization improvement,

ISO 15189 focuses on the application of quality system methods in medical laboratories. Since the publication of ISO 15189:2003, as a recommendation Medical laboratory quality system standards (sometimes mandatory) have been increasingly adopted globally.

To ensure that measurement results are useful and reliable in medical practice and to be able to limit medical decisions to similar results previously measured for the same individual To make meaningful comparisons, medical laboratories need to estimate the overall variability in reported results from measurement procedures. For this purpose, ISO 15189:2012 Requirement 5.5.1.4 in "(Medical laboratories) shall evaluate the measurement accuracy of each measurement procedure used to report measured quantities of patient samples in the test:" Certainty". Furthermore, "on request, laboratories shall provide to their users an estimate of the uncertainty of measurement".

For medical laboratories and medical personnel, estimates of measurement uncertainty (MU).

---Indicates that multiple results may be obtained for a given measurement;

---Prove that the term "the 'true value' of a quantity" is a theoretical concept;

--- Quantified the quality of the results to determine their applicability in medical decision-making;

---Assume that known medically significant biases are eliminated;

--- Helps identify technical steps to reduce MU;

---Allows synthesis with uncertainty from other sources;

---Used to determine whether medically acceptable analytical performance specifications can be achieved;

---Support interpretation of patient results near medical decision limits.

In order to be able to meet the requirements of ISO 15189 for measurement uncertainty assessment, it is necessary to provide techniques for medical laboratories to evaluate MU.

Provide consistent, standardized best practices using language, principles, and statistical methods. JCGM100.2008 "Measurement Data Evaluation Measurement Inaccuracy" The Guide to the Expression of Qualitative Measurements (GUM) is the authoritative reference document on measurement uncertainty, providing in-depth mathematical and metrological information for It is used to conduct a detailed evaluation of the factors to be considered when evaluating the measurement uncertainty of a measurement system, covering many fields such as science and engineering.

Subject. GUM states in the scope section (1.2) that "This document is intended primarily for the measurement uncertainty of physical quantities that are well defined by unique values. express. "GUM also states in the scope section (1.4), "GUM provides general principles for the evaluation and expression of measurement uncertainty, rather than detailed specific technical instructions. GUM does not discuss how the uncertainty of a particular measurement result can be used for different purposes after being evaluated. for example, to conclude whether the result is compatible with other similar results, to determine the tolerance limits of a manufacturing process, or to decide whether it can be safely Take some measures all over the world. Therefore, it is necessary to develop special standards based on GUM to solve problems or instructions unique to certain measurement fields.

Various ways of quantifying uncertainty. These standards may be simplified versions of the GUM, but should include Details of accuracy and complexity. " This document therefore deals with methods for the assessment of measurement uncertainty in results obtained from measuring procedures in medical laboratories which are expected to Used to measure various biological species. These measurands usually exist in complex biological fluids and tissue matrices, and the measured results provide medical Provide medical diagnostic information to service personnel. In contemporary medical laboratories, the vast majority of measurements are performed using commercial equipment, including automated Chemical instruments and packaged test kits. Characterization of the performance of these measurement procedures in end-user laboratories is usually limited to the use Collect empirical performance data using surrogate quality control samples that simulate intended patient samples. These data are often referred to as indoor quality control (IQC) data describing the repeatability and long-term imprecision of a given measurement procedure. For a given measurement procedure, the manufacturer should provide more Information about the uncertainty of high-level elements in the calibration chain and which should be taken into account by medical laboratories in the assessment of measurement uncertainty Inside. Therefore, the GUM top-down method is suitable. See Chapter 6 for specific application examples of this method in medical laboratories. Guidelines for Evaluating Uncertainty of Measurement in Medical Laboratories

1 Scope

This document provides guidance on the evaluation and expression of measurement uncertainty (MU) for quantitative results in medical laboratories and is also applicable to point-of-care testing.

Evaluation of quantitative results obtained by (POCT) systems that are close to medical determination limits. This document also applies to qualitative methods that include measurement steps Evaluation of the measurement uncertainty of the (named) results obtained. In daily testing, it is not recommended to compare the measurement uncertainty assessment results with patient testing.

Results are reported together but should be made available upon request.

Note: See Appendix B for application examples of measurement uncertainty.

2 Normative reference documents

This document has no normative references.

3 Terms and definitions

The following terms and definitions apply to this document.

Standardized terminology database maintained by ISO and IEC at the following address.

---ISO online browsing platform. https://www:iso:org/obp;

3.1 Analyte

The component represented in the name of the measurand.

Example: In the measurand (measurement quantity) of "24h urine total protein mass", "total protein" is the analyte ("mass" is the characteristic). In "Plasma Glucose Substances" In "quantity concentration", "glucose" is the analyte ("quantity concentration of substance" is the characteristic).

Note 1. Sample components with measurable properties.

Note 2. 5.4 in JCGM200.2012 states that "the primary measurement standard is processed by dissolving a known amount of a chemical component in a known volume of solution:" [Source: GB/T 29791.1-2013, 3.3, with modifications]

3.2 Calibration

A set of operations under specified conditions, the first step of which is to determine the quantity provided by a measuring standard (calibrator) with an associated measurement uncertainty The relationship between the value and the corresponding indication value. The second step is to use this relationship to determine the measurement result based on the indication value (unknown sample).

Note 1. Calibration is expressed in the form of text description, calibration function, calibration diagram, calibration curve or calibration table. In some cases, the inclusion of data with associated measurements does not Additive or multiplicative correction of the indication value of the degree of certainty.

Note 2. It is more appropriate that calibration should not be confused with the adjustment of the measurement system (often erroneously called "self-calibration"), nor with calibration verification.

Note 3. Usually, only the first step in the above definition is considered calibration. [Source: JCGM200.2012,2.39, modified]

3.3 Calibrator

Measurement standards used for calibration.

Note 1. In this document, calibrator and calibration substance are synonymous.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 54 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/Z 43280-2023

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
54 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 43280-2023

$875.00