GB/Z 30966.71-2024Wind energy generation systems - Communication for monitoring and control of wind power plant - Part 71: Configuration description language (English PDF)
风能发电系统 风力发电场监控系统通信 第71部分:配置描述语言
This is a limited preview
Buy now to download the full PDF (86 pages)
Need quotation for your management?
Get a formal quotation for GB/Z 30966.71-2024 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 28, 2024
Implementation date
May 28, 2024
Scope
GB/Z 30966.71-2024 is the English-translated version of 风能发电系统 风力发电场监控系统通信 第71部分:配置描述语言.
GB/Z 30966.71-2024 is the Chinese standard "Wind energy generation systems - Communication for monitoring and control of wind power plant - Part 71: Configuration description language".
Its scope clause reads: The purpose of the IEC 61400-25 series of standards is to regulate the communication between wind farm equipment (such as wind turbines) and SCADA systems.
Non-IEC 61850 and non-IEC 61400-25 communication equipment within a wind farm is not within the scope of the IEC 61400-25 series of standards. Within the enclosure.
This document describes how to extend the IEC 61400-25 standard with the Substation Configuration Description Language (SCL) file format for describing wind power substations.
Configuration of intelligent electronic devices (IEDs) related to communication such as generator sets, wind farm controllers, and wind towers. The power sector aims to simplify the integration of wind farm equipment and its integration into the power system for customers.
The system can exchange IED parameters, communication system configuration, switchyard (function) structure and the relationship between them. The purpose of this document is to formally communicate between IED engineering tools and system engineering tools from different manufacturers in a compatible manner.
This document also aims to provide a means to efficiently exchange functional descriptions and system descriptions of intelligent electronic devices in wind turbines and wind farms.
Reports configuration and alarms from the wind farm and HMI interface information. This information can be used to provide information to the wind farm, the connected distribution system Design upper-level SCADA systems for the operator’s maintenance and monitoring systems.
Finally, SCL is intended to be used as configuration and topology documentation for delivered systems. The System Configuration Description Language (SCL) is defined in IEC 61850-6 and is based on the Extensible Markup Language (XML) version 1.0.
This document also includes extensions to the intelligent electronic device and communication system models in SCL to cover IEC 61400-25-2. The SCSM is extended and the usage rules are added to cover all mappings defined in IEC 61400-25-4 and IEC 61400-25-41.
This document does not specify specific implementations or products using the SCL language, nor does it constrain the entities and interfaces within a computer system.
Furthermore, although the SCL format can be used as part of the configuration data, this document does not specify the configuration data to be downloaded to the intelligent electronic device. The format in the IED is not specified.
Found what you need?
Document preview — GB/Z 30966.71-2024
National Standard of the People's Republic of China
- ICS
- 27.180
- Classification
- F 11
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Abbreviations
- 5 Introduction to SCL
- 5.1 General
- 5.2 SCL Part
- 5.3 SCL file type
- 5.4 SCL Tools
- 6 SCL application cases in wind power industry
- 6.1 Overview
- 6.2 IED level interface server configuration
- 6.3 WPPS level interface server configuration
- 6.4 Client Data Flow Definition
- 6.5 Topology Definition
- 7 Mapping specific configuration
- 7.1 General
- 7.2 Web Service Mapping Configuration Parameters - WS Communication Parameters
- 7.3 MMS Mapping Configuration Parameters
- 7.4 IEC 60870-5-101/IEC 60870-5-104 mapping configuration parameters
- 7.5 DNP3 specific mapping configuration parameters
- 7.6 OPCUA Mapping Configuration Parameters - OPCUA Communication Parameters
- Appendix A (informative) SCL mode extension 32 used in IEC 61400-25 projects
- Appendix B (Normative) SCL framework of IEC 61400-25
- Appendix C (Informative) Configuration Example
- References
1 Scope
The purpose of the IEC 61400-25 series of standards is to regulate the communication between wind farm equipment (such as wind turbines) and SCADA systems.
Non-IEC 61850 and non-IEC 61400-25 communication equipment within a wind farm is not within the scope of the IEC 61400-25 series of standards.
Within the enclosure.
This document describes how to extend the IEC 61400-25 standard with the Substation Configuration Description Language (SCL) file format for describing wind power substations.
Configuration of intelligent electronic devices (IEDs) related to communication such as generator sets, wind farm controllers, and wind towers.
The power sector aims to simplify the integration of wind farm equipment and its integration into the power system for customers.
The system can exchange IED parameters, communication system configuration, switchyard (function) structure and the relationship between them.
The purpose of this document is to formally communicate between IED engineering tools and system engineering tools from different manufacturers in a compatible manner.
This document also aims to provide a means to efficiently exchange functional descriptions and system descriptions of intelligent electronic devices in wind turbines and wind farms.
Reports configuration and alarms from the wind farm and HMI interface information. This information can be used to provide information to the wind farm, the connected distribution system
Design upper-level SCADA systems for the operator’s maintenance and monitoring systems.
Finally, SCL is intended to be used as configuration and topology documentation for delivered systems.
The System Configuration Description Language (SCL) is defined in IEC 61850-6 and is based on the Extensible Markup Language (XML) version 1.0.
This document also includes extensions to the intelligent electronic device and communication system models in SCL to cover IEC 61400-25-2.
The SCSM is extended and the usage rules are added to cover all mappings defined in IEC 61400-25-4 and IEC 61400-25-41.
This document does not specify specific implementations or products using the SCL language, nor does it constrain the entities and interfaces within a computer system.
Furthermore, although the SCL format can be used as part of the configuration data, this document does not specify the configuration data to be downloaded to the intelligent electronic device.
The format in the IED is not specified.
2 Normative references
The contents of the following documents constitute the essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to
This document.
IEC 61400-25-1 Wind power generation systems Part 25-1.Communication principles and models for wind farm monitoring systems (Winden-
Note. GB/T 30966.1-2022 Wind turbine wind farm monitoring system communication Part 1.Principles and models (IEC 61400-25-1.
2017, IDT)
IEC 61400-25-2 Wind turbines Part 25-2.Communication information model for wind farm monitoring systems els)
Note. GB/T 30966.2-2022 Wind turbine wind farm monitoring system communication Part 2.Information model (IEC 61400-25-2.
2015, IDT) […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 86 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 61400-25-1 · IEC 61400-25-2
Similar standards
How to Download GB/Z 30966.71-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 102.17-2026 — Semiconductor devices - Discrete devices - Part 17: Magnetic and capacitive coupler for basic and reinforced insulation
GB/Z 103-2026 — Health informatics - The architecture of internet healthcare service network
GB/Z 108-2026 — Health informatics - Internet healthcare service pattern
GB/Z 30966.71-2024
$1,175.00