GB/Z 26208-2010Testing of supplementary systems of photometry (English PDF)
光度辅助测量系统
This is a limited preview
Buy now to download the full PDF (87 pages)
Need quotation for your management?
Get a formal quotation for GB/Z 26208-2010 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
January 14, 2011
Implementation date
January 14, 2011
Scope
GB/Z 26208-2010 is the English-translated version of 光度辅助测量系统.
GB/Z 26208-2010 is a guiding technical document, not a mandatory standard, that reports how ten proposed supplementary photometric systems perform when tested against experimental brightness matching data.
Four systems apply to a 2-degree field of view and six to a 10-degree field, and each is presented with its system equivalent luminance calculation and a worked example.
It sets out the data sources and test procedure, reports the results, adds further tests on data from the CIE 91 study groups, and discusses equivalent luminance calibration and conversion between common reference stimuli.
The tests check how well each system predicts matched brightness rather than absolute luminance levels, and no new CIE system is recommended. Eleven informative appendices supply conversion and adaptation factors, and the text is an identical adoption of CIE 141-2001. It was issued on 14 January 2011.
Found what you need?
Document preview — GB/Z 26208-2010
National Standard of the People's Republic of China
- ICS
- 17.180.20
- Classification
- K 70
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- Introduction
- 1 General
- 2 Metering system for evaluating the brightness of objects and light sources
- 2.1 2 ° field of view system
- 2.2 10 ° field of view system
- 3 Test Data and Test Procedures
- 3.1 Data Sources
- 3.2 Test program proposed system
- 4 test program results
- 4.1 Results of 2 ° field matching data on a 2 ° system
- 4.2 Results of 10 ° field matching data on a 10 ° system
- 5 Other tests based on data from CIE91 study group
- 5.1 CIE91 Study Group Data
- 5.2 Photometry System Test Using Study Group Data
- 6 Discussion
- 6.1 System Equivalent Brightness Calibration
- 6.2 Evaluation of Common Reference Stimulus Transitions
- 7 Summary and Conclusions
- Appendix 1 (Informative) Calculates the luminosity and chromaticity data for the color samples used in the examples
- Appendix 2 (informative) Ware-Cowan conversion factor B/L contours
- Appendix 3 (informative) Sagawa-Takeichi system adaptation factor
- Appendix 4 (informative) Kokoschka-Bodmann system F-factor
- Appendix 5 (informative) Retina illumination and brightness conversion table
- Appendix 6 (informative) Ashizawa-Ikeda system of equivalent brightness
- Appendix 7 (Informative) Surface brightness calculation method
- Appendix 8 (Informative) Data Source for Testing Brightness Matching Data
- Appendix 9 (Informative) CIE91 Melbourne Study Group Data (Corrected EDL-50)
- Appendix 10 (informative) experimental group used in all research groups in different color brightness matching test instruction
- Appendix 11 (Informative) Intermediate Photometry (TC1.21) Minority Report
- References
Foreword
This guideline is equivalent to the CIE141-2001 "Photometric Aided Measurement System" (English version).
This Guidance Document is equivalent to CIE 141-2001.
For ease of use, the following technical editorial changes have been made to this technical document.
a) Replace "This Technical Report" with "This Guidance Technical Paper";
b) Use "." instead of "," as the decimal point
c) Delete the foreword of CIE141-2001;
d) The CIE141-2001 "intermediate photometry (TC1.21) Minority Report" chapter into the informative appendix.
Appendices 1 to 11 of this Guidance Document are informative appendices.
Introduction
This guidance document covers the latest protocols for 10 types of metering systems (4 for a 2 ° field of view and 6 for a 10 ° field of view), which These programs were submitted to Division 1 of the International Commission on Illumination (CIE) as a light-to-light relative to all ranges of human visual acuity Brightness determination method. In order to quantitatively test these systems, a number of applications submitted by independent laboratories for different color brightness Assay (HCBM) Data sets obtained using different stimulation combinations and experimental procedures. Also, six research groups are using the same color Color samples were tested on each system using the data obtained from HCBM experiments under very similar conditions. These numerical tests are mainly Instead of testing the absolute level of the brightness metric, in order to test the equality of the equivalent brightness of the brightness-matching stimulus. This instructional technical article Describe the results of these quantitative tests and make no recommendations regarding the new CIE system.
1 General
The current metering brightness, as defined by the CIE metering system, is not sufficiently correlated with the perceived brightness of colored objects or light sources.
The difference between brightness and brightness, itself manifested as a superposition missing problem; the superposition of two or more monochromatic light source table Viewing brightness often differs from the sum of their brightness. In the bright vision, the superposition effect is usually less than the sum of brightness, then addability missing Loss mainly in the sub-additivity. The current color theory accounts for this phenomenon based on the interaction between human eye cones Helmholtz-Kohlrausch); the saturated color gives a "color contribution" to the physiological brightness signal.
Strong overdisappearances can also occur, in which case the effect of two or more monochromatic light sources superimposing is much greater than their brightness Overlay effect. Since this phenomenon often occurs at intermediate visual levels, it is inferred that it is the interaction between the human eye's cones - the human eye's rod cells The result of the action. Spectral sensitivity changes from human eye cones to human eye rod cells, accompanied by a reduction in apparent brightness, In terms of shades of light, the brightness of blue light is enhanced. In dark vision, this purkinjeshift is complete, because Here, the phenomenon of overlay loss tends to disappear.
Recognizing these differences in brightness and brightness, Division 1 of CIE has appointed several technical committees in the past 15 years Will investigate the issue of Heterochromatic Brightness Matching (HCBM) and work hard to develop a new type of metering system for measuring brightness. The earliest Several technical committees are shown below.
TC1-01 Intermediate Visual Photometry (by JAS Kinney)
TC1-02 luminous efficiency function (by M. Ikeda)
TC1-03 Heterogeneous luminance matching model (by PKKaiser)
TC1-01 provides an excellent summary of intermediate vision photometry systems that have emerged since the late 1980s Ming Committee, 1989) laid the foundation for TC1-21. The TC1-02 is built for point light sources at 2 ° and 10 ° field-of-view, depending on the brightness of the light Degree of spectral luminous efficiency function (International Commission on Illumination, 1988). These luminous efficiency functions can not only be used as a photometric reference data, But also provides reference data for the further study of different color brightness matching test. TC1-03 investigated and studied the brightness matching test Physiological model of the trial (International Commission on Illumination, 1986).
In response to these technical committee initiatives, some research groups have proposed photometric system solutions based on different color brightness matching tests.
Taking into account the future development of international standards, the standard required to provide a satisfactory, suitable for all brightness levels of brightness measurement Volume 1, Division 1 evaluated these systems.
TC1-21, Testing of Auxiliary Metering Systems, at the 21st Annual International Lighting Convention, Venice, 1987 Set up The technical committee directly quantified the system by using the proposed system for data from HCBM experiments test. Its mission is to report how well the system predicts these data. However, its terms of reference will not extend to recommending any one System as an international lighting standard.
The current report provides numerical data and procedures for testing. Considering the predictability of the relationship between the brightness of colored objects or light sources is One of the main functions of photometric measurement, the current test is designed to be used for each proposed system to verify that its description is from the HCBM test The brightness of the test match the brightness of the same degree of the pros and cons.
Chapter 1 points out the problems with the current lighting system of the International Commission on Illumination and the setting of TC1-21 to solve these problems aims. Chapter 2 outlines the currently proposed HCBM-based metering system, updated TC1-01 report (International Lighting Commission Yes, 1989) and added some recently proposed systems. For each system, this chapter provides a calculation for "system equivalent brightness" As well as a computational example, "System Equivalent Luminance" is used as a measure of apparent brightness for a particular reference stimulus. Chapter 3 describes it System testing selected data sets and testing process. Chapter 4 reports on the application of the proposed metering system to these data sets System equivalent brightness. Chapter 5 reports on the quantitative results obtained using these systems on a new dataset from Tests carried out in six laboratories in four different countries under general stimulation and general test conditions are those of TC1-21 for.1991
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 87 pages — is available in the English PDF.
Similar standards
How to Download GB/Z 26208-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 102.17-2026 — Semiconductor devices - Discrete devices - Part 17: Magnetic and capacitive coupler for basic and reinforced insulation
GB/Z 103-2026 — Health informatics - The architecture of internet healthcare service network
GB/Z 108-2026 — Health informatics - Internet healthcare service pattern
GB/Z 26208-2010
$1,160.00