Valid

GB/T 9966.16-2021Test methods for natural stone—Part 16: Determination of linear thermal expansion coefficient (English PDF)

天然石材试验方法 第16部分:线性热膨胀系数的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for GB/T 9966.16-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

April 30, 2021

Implementation date

November 1, 2021

Scope

GB/T 9966.16-2021 is the English-translated version of 天然石材试验方法 第16部分:线性热膨胀系数的测定.

GB/T 9966.16-2021 is the part of the Chinese series of test methods for natural stone that measures the coefficient of linear thermal expansion.

It gives the principle, the equipment, the preparation of the specimens, the test procedure, the calculation of the result and the test report, and it describes the mechanical measurement (method A) and the alternative technique, saying which one applies to which kind of stone.

It applies to the determination of the linear thermal expansion coefficient of natural stone, a figure needed when cladding panels are fixed to a façade that moves with temperature.

Quarries, stone processors and façade designers use it. Issued on 30 April 2021, it has applied since 1 November 2021.

Found what you need?

Document preview — GB/T 9966.16-2021

National Standard of the People's Republic of China

ICS
91.100.15
Classification
Q 21

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 3 Principles
  • 4 Instruments and Equipment
  • 5 Sample Preparation
  • 6 Experimental Procedure
  • 7 Test Results
  • 8 Test Reports
  • Foreword
  • 1 Scope
  • 3 Principles
  • 4 Instruments and Equipment
  • 5 Sample Preparation
  • 6 Experimental Procedure
  • 7 Test Results
  • 8 Test Reports

Foreword

GB/T 9966 "Test Methods for Natural Stone" consists of 18 parts.

Part 1: Compression strength test after drying, water saturation, and freeze-thaw cycles;

Part 2: Bending strength test after drying, water saturation, and freeze-thaw cycles;

Part 3: Water absorption, bulk density, true density, and true porosity tests;

Part 4: Abrasion Resistance Test;

Part 5: Hardness Test;

Part 6: Acid Resistance Test;

Part 7: Strength Test of Stone Hanging Component Assembly Unit.

Part 8: Test Method for Structural Strength Testing of Stone Hanging Systems Using Uniform Static Pressure Difference;

Part 9: Determination of dynamic elastic modulus by measuring the fundamental resonant frequency;

Part 10: Determination of the seismic performance of the hanger assembly unit;

Part 11: Determination of Accelerated Aging Strength Due to Rapid Cooling and Heating;

Part 12: Determination of Static Modulus of Elasticity;

Part 13: Determination of capillary water absorption coefficient;

Part 14: Determination of fracture resistance energy;

Part 15: Determination of Salt Spray Aging Resistance;

Part 16: Determination of the linear thermal expansion coefficient;

Part 17: Determination of Salt Crystallization Strength Part 18: Lithofacies Analysis.

This part is Part 16 of GB/T 9966.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This part of GB/T 9966 specifies the principle, equipment, sample preparation, and test procedures for the linear thermal expansion coefficient test of natural stone.

Steps, test results, and test report.

This section applies to the determination of the linear thermal expansion coefficient of natural stone. Mechanical measurement (Method A) is applicable to stones with a maximum particle size greater than [missing value].

For 7mm stone, the thermal expansion meter measurement (Method B) is applicable to stone with a maximum particle size of no more than 7mm.

3 Principles

After the sample is dried to constant weight, the length change in a certain direction at at least two different temperatures is measured, and the linear thermal expansion coefficient between the two temperatures is listed in the table.

This represents the change in length per unit length when the temperature changes by 1°C.

4 Instruments and Equipment

4.1 Forced air drying oven. capable of maintaining the temperature at (65±5)C.

4.2 Constant Temperature Chamber. Capable of raising the temperature from (20 ± 0.5) °C to (80 ± 0.5) °C at a rate of 0.5 °C/min, and maintaining the temperature within the specified range.

The temperature should be measured for at least 2 hours, with a minimum accuracy of ±0.5°C.

4.3 Vernier calipers. accurate to 0.01 mm.

4.4 Micrometer and conversion device (Method A). accurate to 0.001 mm.

4.5 Thermal expansion meter (Method B). Length measurement accuracy not less than 0.0005 mm, temperature measurement accuracy not less than ±0.1°C.

5 Sample Preparation

5.1 Sampling

At least two samples should be prepared in the same direction from the same batch of products, and the length of the samples should be the same as the application direction. No adverse reactions should occur in the samples.

Various defects related to thermal expansion, such as cracks, color spots, and color lines, should be addressed by grinding the two end faces of the sample along its length until they are smooth.

Note: Due to the anisotropy of rocks, the coefficient of thermal expansion may vary depending on the measurement direction. When anisotropic surfaces (such as bedding, foliation, etc.) are present on the sample... Use two parallel lines to indicate the direction. If it is necessary to measure the coefficient of thermal expansion in other directions, prepare the same number of lengths along those other directions simultaneously as required. The sample.

5.2 Sample Specifications

For mechanical measurement (Method A), the rectangular sample size is 250mm x 50mm x 20mm, with a deviation of ±1mm; thermal expansion meter measurement... (Method B) The rectangular sample dimensions are 70mm x 50mm x 20mm, with a deviation of ±1mm. If the maximum particle size in the sample exceeds... The sample length should be at least 10 times the maximum particle size, and the sample diameter should be 7 mm.

5.3 Sample handling

The sample was dried in a forced-air drying oven at (65±5)°C for 48 hours until constant weight, and then placed in a desiccator to cool to room temperature.

The sample was placed in a forced-air drying oven at (20 ± 0.5)°C, and the temperature was stabilized for at least 30 minutes. Then, the drying rate was increased to 0.5°C/min.

The rate was set to bring the temperature to (80±0.5)C and stabilize it for at least 30 min.

Lower the temperature to the initial temperature (20 ± 0.5) °C, and use the same steps to ensure that each sample completes at least two consecutive thermal cycles.

Eliminate changes caused by heating.

6 Experimental Procedure

6.1 Mechanical Measurement (Method A)

6.1.1 Place the sample in a forced-air drying oven at a temperature of (20 ± 0.5)°C, and maintain the temperature stable at ±0.5°C for at least [duration not specified].

30 min.

6.1.2 Take out each sample and quickly measure its length, accurate to 0.01 mm, and fix its initial position on the length conversion device.

6.1.3 Record the initial length (l20) and corresponding temperature (t20) of each sample, accurate to 0.5°C.

6.1.4 Place the sample back into the forced-air drying oven and raise the temperature to (80 ± 0.5)°C at a rate of 0.5°C/min, then maintain the temperature stable.

No less than 30 minutes.

6.1.5 Remove each sample and quickly mark its length position on the length conversion device. Measure its length change with a micrometer, accurate to [value missing].

0.00lmm.

6.1.6 Record the length variation (l8°-l2°) and corresponding temperature (t8°) of each sample, accurate to 0.5°C.

6.2 Thermal expansion tester measurement (Method B)

6.2.1 Place the sample in a thermal dilatometer and maintain it at the initial temperature (20 ± 0.5)°C for at least 2 hours, then measure the length, accurate to [value missing].

Record the initial length (l20) and corresponding temperature (t20) of the sample, accurate to 0.1°C, with a diameter of 0.0005 mm.

6.2.2 Increase the temperature to (80±0.5)°C at a rate of 0.5°C/min, maintain this temperature for at least 2 hours, and then measure the length of the sample accurately.

Record the sample length (l8°) and corresponding temperature (t8°) to 0.0005 mm, with the temperature accurate to 0.1°C.

Note: The coefficient of thermal expansion is not entirely linear with temperature. The method described in this section treats the coefficient of thermal expansion of stone as linear within the temperature range of 20°C to 80°C.

If it is necessary to evaluate the linearity of the coefficient of thermal expansion, perform intermediate measurements using the same procedure at intervals of (20±1)°C during the heating process, and then plot the phase.

The corresponding curve is provided, and the coefficient of thermal expansion can also be measured in different temperature ranges as required.

7 Test Results

Calculate the coefficient of thermal expansion for each sample according to formula (1).

Calculate the average linear thermal expansion coefficient for each group of samples, retaining two significant figures. The test results are expressed as the arithmetic mean of each group of samples. express.

8 Test Reports

The test report should include at least the following information.

a) The commercial name of the stone as specified in GB/T 17670;

b) Sample quantity, dimensions, surface treatment (as required for testing), and orientation of anisotropic surfaces;

c) The name and address of the laboratory where the test was conducted; if the test was not conducted in a testing laboratory, the location of the test should be noted.

d) The standard number followed in the test (GB/T 9966.16-2021);

e) Test methods, sample conditions, and temperature during testing;

f) The linear thermal expansion coefficient, arithmetic mean, and correlation curve (if applicable) for each sample.

GB/T 9966.16-2021. Test methods for natural stone - Part 16. Determination of the linear coefficient of thermal expansion

ICS 91.100.15 National Standards of the People's Republic of China Natural Stone Testing Methods Part 16: Determination of the linear thermal expansion coefficient Published on 2021-04-30 Implemented on 2021-11-01 State Administration for Market Regulation release National Standardization Management Committee

Foreword

GB/T 9966 "Test Methods for Natural Stone" consists of 18 parts.

Part 1: Compression strength test after drying, water saturation, and freeze-thaw cycles;

Part 2: Bending strength test after drying, water saturation, and freeze-thaw cycles;

Part 3: Water absorption, bulk density, true density, and true porosity tests;

Part 4: Abrasion Resistance Test;

Part 5: Hardness Test;

Part 6: Acid Resistance Test;

Part 7: Strength Test of Stone Hanging Component Assembly Unit.

Part 8: Test Method for Structural Strength Testing of Stone Hanging Systems Using Uniform Static Pressure Difference;

Part 9: Determination of dynamic elastic modulus by measuring the fundamental resonant frequency;

Part 10: Determination of the seismic performance of the hanger assembly unit;

Part 11: Determination of Accelerated Aging Strength Due to Rapid Cooling and Heating;

Part 12: Determination of Static Modulus of Elasticity;

Part 13: Determination of capillary water absorption coefficient;

Part 14: Determination of fracture resistance energy;

Part 15: Determination of Salt Spray Aging Resistance;

Part 16: Determination of the linear thermal expansion coefficient;

Part 17: Determination of Salt Crystallization Strength Part 18: Lithofacies Analysis.

This part is Part 16 of GB/T 9966.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This part of GB/T 9966 specifies the principle, equipment, sample preparation, and test procedures for the linear thermal expansion coefficient test of natural stone.

Steps, test results, and test report.

This section applies to the determination of the linear thermal expansion coefficient of natural stone. Mechanical measurement (Method A) is applicable to stones with a maximum particle size greater than [missing value].

For 7mm stone, the thermal expansion meter measurement (Method B) is applicable to stone with a maximum particle size of no more than 7mm.

3 Principles

After the sample is dried to constant weight, the length change in a certain direction at at least two different temperatures is measured, and the linear thermal expansion coefficient between the two temperatures is listed in the table.

This represents the change in length per unit length when the temperature changes by 1°C.

4 Instruments and Equipment

4.1 Forced air drying oven. capable of maintaining the temperature at (65±5)C.

4.2 Constant Temperature Chamber. Capable of raising the temperature from (20 ± 0.5) °C to (80 ± 0.5) °C at a rate of 0.5 °C/min, and maintaining the temperature within the specified range.

The temperature should be measured for at least 2 hours, with a minimum accuracy of ±0.5°C.

4.3 Vernier calipers. accurate to 0.01 mm.

4.4 Micrometer and conversion device (Method A). accurate to 0.001 mm.

4.5 Thermal expansion meter (Method B). Length measurement accuracy not less than 0.0005 mm, temperature measurement accuracy not less than ±0.1°C.

5 Sample Preparation

5.1 Sampling

At least two samples should be prepared in the same direction from the same batch of products, and the length of the samples should be the same as the application direction. No adverse reactions should occur in the samples.

Various defects related to thermal expansion, such as cracks, color spots, and color lines, should be addressed by grinding the two end faces of the sample along its length until they are smooth.

Note: Due to the anisotropy of rocks, the coefficient of thermal expansion may vary depending on the measurement direction. When anisotropic surfaces (such as bedding, foliation, etc.) are present on the sample... Use two parallel lines to indicate the direction. If it is necessary to measure the coefficient of thermal expansion in other directions, prepare the same number of lengths along those other directions simultaneously as required. The sample.

5.2 Sample Specifications

For mechanical measurement (Method A), the rectangular sample size is 250mm x 50mm x 20mm, with a deviation of ±1mm; thermal expansion meter measurement... (Method B) The rectangular sample dimensions are 70mm x 50mm x 20mm, with a deviation of ±1mm. If the maximum particle size in the sample exceeds... The sample length should be at least 10 times the maximum particle size, and the sample diameter should be 7 mm.

5.3 Sample handling

The sample was dried in a forced-air drying oven at (65±5)°C for 48 hours until constant weight, and then placed in a desiccator to cool to room temperature.

The sample was placed in a forced-air drying oven at (20 ± 0.5)°C, and the temperature was stabilized for at least 30 minutes. Then, the drying rate was increased to 0.5°C/min.

The rate was set to bring the temperature to (80±0.5)C and stabilize it for at least 30 min.

Lower the temperature to the initial temperature (20 ± 0.5) °C, and use the same steps to ensure that each sample completes at least two consecutive thermal cycles.

Eliminate changes caused by heating.

6 Experimental Procedure

6.1 Mechanical Measurement (Method A)

6.1.1 Place the sample in a forced-air drying oven at a temperature of (20 ± 0.5)°C, and maintain the temperature stable at ±0.5°C for at least [duration not specified].

30 min.

6.1.2 Take out each sample and quickly measure its length, accurate to 0.01 mm, and fix its initial position on the length conversion device.

6.1.3 Record the initial length (l20) and corresponding temperature (t20) of each sample, accurate to 0.5°C.

6.1.4 Place the sample back into the forced-air drying oven and raise the temperature to (80 ± 0.5)°C at a rate of 0.5°C/min, then maintain the temperature stable.

No less than 30 minutes.

6.1.5 Remove each sample and quickly mark its length position on the length conversion device. Measure its length change with a micrometer, accurate to [value missing].

0.00lmm.

6.1.6 Record the length variation (l8°-l2°) and corresponding temperature (t8°) of each sample, accurate to 0.5°C.

6.2 Thermal expansion tester measurement (Method B)

6.2.1 Place the sample in a thermal dilatometer and maintain it at the initial temperature (20 ± 0.5)°C for at least 2 hours, then measure the length, accurate to [value missing].

Record the initial length (l20) and corresponding temperature (t20) of the sample, accurate to 0.1°C, with a diameter of 0.0005 mm.

6.2.2 Increase the temperature to (80±0.5)°C at a rate of 0.5°C/min, maintain this temperature for at least 2 hours, and then measure the length of the sample accurately.

Record the sample length (l8°) and corresponding temperature (t8°) to 0.0005 mm, with the temperature accurate to 0.1°C.

Note: The coefficient of thermal expansion is not entirely linear with temperature. The method described in this section treats the coefficient of thermal expansion of stone as linear within the temperature range of 20°C to 80°C.

If it is necessary to evaluate the linearity of the coefficient of thermal expansion, perform intermediate measurements using the same procedure at intervals of (20±1)°C during the heating process, and then plot the phase.

The corresponding curve is provided, and the coefficient of thermal expansion can also be measured in different temperature ranges as required.

7 Test Results

Calculate the coefficient of thermal expansion for each sample according to formula (1).

Calculate the average linear thermal expansion coefficient for each group of samples, retaining two significant figures. The test results are expressed as the arithmetic mean of each group of samples. express.

8 Test Reports

The test report should include at least the following information.

a) The commercial name of the stone as specified in GB/T 17670;

b) Sample quantity, dimensions, surface treatment (as required for testing), and orientation of anisotropic surfaces;

c) The name and address of the laboratory where the test was conducted; if the test was not conducted in a testing laboratory, the location of the test should be noted.

d) The standard number followed in the test (GB/T 9966.16-2021);

e) Test methods, sample conditions, and temperature during testing;

f) The linear thermal expansion coefficient, arithmetic mean, and correlation curve (if applicable) for each sample.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

Similar standards

How to Download GB/T 9966.16-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 9966.16-2021

$90.00