GB/T 8151.12-2012Methods for chemical analysis of zinc concentrates - Part 12: Determination of sliver content - The flame atomic absorption spectrometric method (English PDF)
锌精矿化学分析方法 第12部分:银量的测定 火焰原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 8151.12-2012 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 31, 2012
Implementation date
October 1, 2013
Scope
GB/T 8151.12-2012 is the English-translated version of 锌精矿化学分析方法 第12部分:银量的测定 火焰原子吸收光谱法.
GB/T 8151.12-2012 is the Chinese standard "Methods for chemical analysis of zinc concentrates - Part 12: Determination of sliver content - The flame atomic absorption spectrometric method".
Its scope clause reads: This section GB/T 8151 provisions of the determination of the amount of silver in the zinc concentrate. This section applies to the determination of zinc concentrates - Determination of silver content range..
20g/t ~ 1000g/t. Its clauses include method summary; reagents; instrument; sample.
Found what you need?
Document preview — GB/T 8151.12-2012
National Standard of the People's Republic of China
- ICS
- 77.120.60
- Classification
- H 13
- Replacing
- GB/T 8151.12-2000
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Method summary
- 3 Reagents
- 4 Instrument
- 5 Sample
1 Scope
This section GB/T 8151 provisions of the determination of the amount of silver in the zinc concentrate.
This section applies to the determination of zinc concentrates - Determination of silver content range.. 20g/t ~ 1000g/t.
2 Method summary
Samples with hydrochloric acid, nitric acid dissolved in dilute hydrochloric acid medium, atomic absorption spectrometer at a wavelength of 328.1nm, air - acetylene flame,
Measuring the absorbance of silver.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical reagent and distilled or deionized water or equivalent purity.
3.1
hydrochloric acid (rho1.19g/mL), pure class distinctions.
3.2
nitrate (rho1.42g/mL), pure class distinctions.
3.3
hydrochloride (11).
3.4
nitric acid (11).
3.5 silver standard stock solution
Weigh 0.5000g metallic silver (wAg>=99.99%) in 100mL beaker, add 20mL of nitric acid (3.4), heat gently to dissolve completely, boiled to remove nitrogen oxides, cooled to room temperature, transferred to 1000mL volumetric flask, 20mL of nitric acid was added (3.4), with no chlorine ions is diluted with water to volume, and mix. This solution 1mL containing 0.5mg silver.
3.6 Silver standard solution
Pipette 5.00mL standard silver stock solution (3.5) in 100mL volumetric flask, was added 4mL of nitric acid (3.4), with
Dilution water does not contain chlorine ions to the mark, and mix. This solution 1mL containing 25µg silver.
4 Instrument
Atomic absorption spectrometer and Silver hollow cathode lamp.
Under optimum working conditions for those who can reach the following indicators can be used.
--- Characteristic concentration. in the matrix solution consistent with the measurement sample solution is characterized in silver concentration should not exceed 0.06µg/mL;
--- Precision. with the highest concentration of the standard solution absorbance measured 10 times, and the standard deviation shall not exceed 1.50% of the average absorbance;
The lowest concentration of standard solution used (instead of "zero" concentration of the standard solution) absorbance measured 10 times, and the standard deviation should not exceed the maximum
0.50% Average high concentration of the standard solution absorbance;
--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment
Ratio of not less than 0.7.
5 Sample
5.1
Samples should sift through the 0.100mm hole.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
Editions of GB/T 8151.12
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 8151.12-2012 | Methods for chemical analysis of zinc concentrates - Part 12: Determination of sliver content - The flame atomic absorption spectrometric method | current edition | Current |
| GB/T 8151.12-2000 | Methods for chemical analysis of zinc concentrates - Part 12: Determination of sliver content - The flame atomic absorption spectrometric method | previous edition | Superseded |
This page sells the current edition, GB/T 8151.12-2012. Earlier editions are listed for reference only.
How to Download GB/T 8151.12-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 8151.1-2012 — Methods for chemical analysis of zinc concentrates -- Part 1: Determination of zinc content -- Precipitate separation-Na2EDTA titrimetric method and extractive separation -- Na2EDTA titrimetric method
GB/T 8151.10-2012 — Methods for chemical analysis of zinc concentrates - Part 10: Determination of tin content - Hydride generation-atomic fluorescence spectrometry
GB/T 8151.11-2012 — Methods for chemical analysis of zinc concentrates - Part 11: Determination of antimony content - Hydride generation-atomic fluorescence spectrometry