GB/T 6730.9-2016Iron ores - Determination of silicon content - The silicomolybdic blue spectrophotometric method reduced by ammonium ferrous sulfate (English PDF)
铁矿石 硅含量的测定 硫酸亚铁铵还原-硅钼蓝分光光度法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 6730.9-2016 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 13, 2016
Implementation date
September 1, 2017
Scope
GB/T 6730.9-2016 is the English-translated version of 铁矿石 硅含量的测定 硫酸亚铁铵还原-硅钼蓝分光光度法.
GB/T 6730.9-2016 is the Chinese standard "Iron ores - Determination of silicon content - The silicomolybdic blue spectrophotometric method reduced by ammonium ferrous sulfate".
Its scope clause reads: This Part of GB/T 6730 specifies the determination of silicon content through the silicomolybdic blue spectrophotometric method reduced by ammonium ferrous sulfate.
This Part is applicable to the determination of silicon content in natural iron ore, iron concentrate, sinter and pellets. The range of determination (mass fraction) is: 0.10% ~ 5.00%. Its clauses include principle; reagents; result calculation.
Found what you need?
Document preview — GB/T 6730.9-2016
National Standard of the People's Republic of China
- ICS
- 73.060.10
- Classification
- D 31
- Replacing
- GB/T 6730.9-2006
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Principle5
- 4 Reagents5
- 5 Instruments6
- 6 Sampling and Sample Preparation6
- 7 Analytical Procedures6
- 8 Result Calculation8
- 9 Test Report11
- Appendix B (informative) Iron Ore Specimens for Precision Test13
1 Scope
This Part of GB/T 6730 specifies the determination of silicon content through the silicomolybdic blue spectrophotometric method reduced by ammonium ferrous sulfate.
This Part is applicable to the determination of silicon content in natural iron ore, iron concentrate, sinter and pellets. The range of determination (mass fraction) is: 0.10% ~ 5.00%.
2 Normative References
The following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
GB/T 6730.1 Iron Ores - Preparation of Predried Test Samples for Chemical Analysis
GB/T 8170 Rules of Rounding off for Numerical Values & Expression and Judgement of
Limiting Values
GB/T 10322.1 Iron Ores - Sampling and Sample Preparation Procedures
GB/T 12806 Laboratory Glassware - One-mark Volumetric Flasks
GB/T 12807 Laboratory Glassware - Graduated Pipettes
GB/T 12808 Laboratory Glassware - One Mark Pipettes
3 Principle
Use sodium carbonate-boric acid mixed flux to melt the specimen, use dilute sulfuric acid to leach it, under acidic conditions, silicic acid and ammonium molybdate form yellow molybdenum silicon heteropoly acid, then, add oxalic acid to eliminate the interference of phosphorus and arsenic, and use ferrous ammonium sulfate to reduce silicon molybdenum heteropoly to silicon molybdenum blue. At a wavelength of 760 nm, measure the absorbance, thereby, determining the silicon content.
4 Reagents
Unless it is otherwise specified, only use the recognized reagents of analytical purity and distilled water complying with the stipulations of GB/T 6682, or water of equivalent purity in the analysis.
4.1
Mixed flux, take 3 portions of anhydrous sodium carbonate and 1 portion of boric acid, evenly grind and mix them.
4.2 Sulfuric acid
rho = 1.89 g/mL.
4.3 Sulfuric acid
5 + 95.
4.4
Oxalic acid solution, 50 g/L.
4.5
Ammonium ferrous sulfate solution, 30 g/L.
Weigh-take 3 g of ferrous ammonium sulfate [(NH4 )2 Fe(SO4 )2 - 6H2 O], add 1 mL of sulfuric acid (1 + 1), use water to dilute to 100 mL; dissolve and filter for use. It shall remain valid for
1 week.
4.6
Ammonium molybdate solution, 50 g/L. Store it in a plastic bottle.
4.7
Silicon standard solution.
4.7.1
Silicon stock solution, 200.0 µg/mL.
Weigh-take 0.2140 g of silicon dioxide (above 99.9%) that has been burned to a constant mass at 1,000 °C, place it in a platinum crucible containing 4 g of mixed flux (4.1), carefully and mix it well, then, use 1 g of mixed flux (4.1) to cover it. Cover the platinum cover, melt and decompose it at 900 °C ~ 950 °C for 30 min, take it out, slowly turn it to make the molten liquid evenly distributed on the inner wall of the crucible and cool it down. Put the crucible and the cover into a polytetrafluoroethylene beaker filled with water, at a low temperature, heat and leach it, then, wash the crucible and the cover. Cool it to room temperature, transfer the leaching solution into a 500 mL volumetric flask; use water to dilute to the mark, mix it well, then, immediately transfer it to a plastic bottle for storage.
7.2 Amount of Specimen
Weigh-take 0.20 g of specimen, accurate to 0.0001 g.
7.3 Blank Test and Verification Test
7.3.1 Blank Test
Weigh-take the same amount of high-purity ferric oxide (iron content greater than 99.98%) as the specimen; along with the specimen, conduct a blank test.
7.3.2 Verification test
Along with the specimen, analyze the same type of reference sample.
7.4 Determination
7.4.1 Specimen decomposition
Place the specimen in a platinum crucible containing 4 g of mixed flux (4.1), carefully and mix it well, then, use 1 g of mixed flux (4.1) to cover it. Cover the platinum cover, melt and decompose it at 900 °C ~ 950 °C for 15 min ~ 30 min, take out the crucible, slowly turn it to make the molten liquid evenly distributed on the inner wall of the crucible and cool it down.
Put the cooled crucible in a beaker filled with 200 mL of sulfuric acid (4.3), at a low temperature, heat and leach it, then, wash the platinum crucible and the cover, and cool to room temperature.
Transfer the leaching solution into a 250 mL volumetric flask, use water to dilute to the mark, mix it well and reserve it for later use. If there is precipitation, adopt the dry filtration method to filter it.
7.4.2 Color development
Respectively take two portions of 5.00 mL (when the silicon content is less than 1%, respectively take 10.00 mL) of the solution (7.4.1) in 100 mL volumetric flasks. One is used as a color developing solution, and the other is used as a reference solution.
a) Color developing solution
Take one portion of the test solution, add 5 mL of ammonium molybdate solution (4.6), add 30 mL of water to mix it well, and let it stand for 15 min (when the room temperature is lower than 15 °C, let it stand for 40 min or heat it in a boiling water bath for 30 s, then, immediately cool it). Add 10 mL of oxalic acid solution (4.4) and mix it well; within 30 s after the solution becomes clear, add 10 mL of ammonium ferrous sulfate solution (4.5), use water to dilute to the mark and mix it well.
b) Reference solution
Take the other portion of the test solution, add 10 mL of oxalic acid solution (4.4), 5 mL of ammonium molybdate solution (4.6) and 10 mL of ammonium ferrous sulfate solution (4.5); use water to dilute to the mark and mix it well.
7.4.3 Absorbance measurement
At a wavelength of 760 nm of the spectrophotometer, use an appropriate cuvette to measure the absorbance, subtract the absorbance of the blank test solution, and find out the content of silicon in the test solution on the calibration curve. For specimens with a silicon content lower than
0.5%, the absorbance may be measured at a wavelength of 810 nm.
7.4.4 Preparation of calibration curve
7.4.4.1
When the silicon content is 0.1% ~ 1.0%
Respectively take 0 mL, 1.00 mL, 3.00 mL, 5.00 mL, 7.00 mL and 9.00 mL of silicon standard solution (4.7.3) into 100 mL volumetric flasks. Add 10 mL of the blank test solution (7.3.1) and
5 mL of ammonium molybdate solution (4.6), use water to dilute to 40 mL and mix it well. Let it stand for 15 min (when the room temperature is lower than 15 °C, let it stand for 40 min or heat it in a boiling water bath for 30 s, then, immediately cool it). Add 10 mL of oxalic acid solution (4.4) and mix it well; within 30 s after the solution becomes clear, add 10 mL of ammonium ferrous sulfate solution (4.5), use water to dilute to the mark and mix it well. Take the color developing solution without silicon as a reference, at a wavelength of 760 nm of the spectrophotometer, select an appropriate cuvette, measure the absorbance and draw a calibration curve.
7.4.4.2
When the silicon content is 1.0% ~ 5.0%
Respectively take 0 mL, 1.00 mL, 2.00 mL, 3.00 mL, 4.00 mL and 5.00 mL of silicon standard solution (4.7.2) into 100 mL volumetric flasks. Add 5 mL of the blank test solution (7.3.1) and
5 mL of ammonium molybdate solution (4.6), use water to dilute to 40 mL and mix it well. Let it stand for 15 min (when the room temperature is lower than 15 °C, let it stand for 40 min or heat it in a boiling water bath for 30 s, then, immediately cool it). Add 10 mL of oxalic acid solution (4.4) and mix it well; within 30 s after the solution becomes clear, add 10 mL of ammonium ferrous sulfate solution (4.5), use water to dilute to the mark and mix it well. Take the color developing solution without silicon as a reference, at a wavelength of 760 nm of the spectrophotometer, select an appropriate cuvette, measure the absorbance and draw a calibration curve.
8 Result Calculation
8.1 Calculation of Silicon Content
In accordance with Formula (1), calculate the silicon content (mass fraction) wSi in the specimen:
8.2.3 Inter-laboratory precision
The inter-laboratory precision is used to evaluate the consistency between the final results reported by two laboratories. After the two laboratories report the results in accordance with the same steps specified in 8.2.2, in accordance with Formula (6), calculate the average valueµ12 of the final results:
Where,
µ1 ---the final results reported by Laboratory 1;
µ2 ---the final results reported by Laboratory 2;
µ12 ---the average value of the final results.
If µ1 -µ2 <= P (see 8.2.1), the final results are consistent.
8.2.4 Acceptance of analytical values
The acceptance of analytical values is verified using certified reference samples. The steps are the same as described above. After confirming the precision, the final laboratory results are compared with the standard value Ac . For example:
a) µc - Ac <= C, there is no significant difference between the measured value and the standard value.
b) µc - Ac > C, there is a significant difference between the measured value and the standard value.
Where,
µc ---the measured value of the reference sample;
Ac ---the standard value of the reference sample;
C---this value depends on the type of reference sample used.
For the reference sample determined by inter-laboratory, in accordance with Formula (7), calculate C:
Where, V (Ac ) is the variance of the standard value Ac .
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB/T 6730.9
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 6730.9-2016 | Iron ores - Determination of silicon content - The silicomolybdic blue spectrophotometric method reduced by ammonium ferrous sulfate | current edition | Current |
| GB/T 6730.9-2006 | Iron ores - Determination of silicon content - The silicomolybdic blue spectrophotometric method reduced by ammonium ferrous sulfate | previous edition | Superseded |
This page sells the current edition, GB/T 6730.9-2016. Earlier editions are listed for reference only.
How to Download GB/T 6730.9-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6730.1-2016 — Iron ores -- Preparation of pre-dried test samples for chemical analysis
GB/T 6730.10-2014 — Iron ores -- Determination of silicon content -- Gravimetric methods
GB/T 6730.11-2025 — Iron ores - Determination of aluminium content - EDTA titrimetric method
Secure payment via Stripe
Payments accepted
GB/T 6730.9-2016
$145.00