Valid

GB/T 6150.7-2008Methods for chemical analysis of tungsten concentrates - Determination of tantalum content and niobium content - Inductively coupled plasma emission spectrometry and spectrophotometry (English PDF)

钨精矿化学分析方法 钽铌量的测定 等离子体发射光谱法和分光光度法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 6150.7-2008 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 17, 2008

Implementation date

December 1, 2008

Scope

GB/T 6150.7-2008 is the English-translated version of 钨精矿化学分析方法 钽铌量的测定 等离子体发射光谱法和分光光度法.

GB/T 6150.7-2008 is the Chinese standard "Methods for chemical analysis of tungsten concentrates - Determination of tantalum content and niobium content - Inductively coupled plasma emission spectrometry and spectrophotometry".

Its scope clause reads: This method specifies the amount of tantalum, niobium determination of the amount of tungsten concentrate. This method is applicable to the determination of the amount of tungsten concentrates tantalum, niobium content.

Measurement range. tantalum oxide mass fraction of 0.020% to 1.00%, five Niobium pentoxide mass fraction of 0.020% to 1.00%. Its clauses include method summary; reagents; instrument; sample.

Found what you need?

Document preview — GB/T 6150.7-2008

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 63
Replacing
GB/T 6150.9-1985

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument
  • 5 Sample

1 Scope

This method specifies the amount of tantalum, niobium determination of the amount of tungsten concentrate.

This method is applicable to the determination of the amount of tungsten concentrates tantalum, niobium content. Measurement range. tantalum oxide mass fraction of 0.020% to 1.00%, five

Niobium pentoxide mass fraction of 0.020% to 1.00%.

2 Method summary

Sample with nitric acid, hydrofluoric acid dissolved, the solution by ICP spectrometer to eliminate interference on the determination of tungsten matrix matching method.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.

3.1

nitrate (rho1.42g/mL), pure class distinctions.

3.2

hydrofluoric acid (rho1.14g/mL), pure class distinctions.

3.3

metatungstate (AMT) .( AMT) >=99.99%.

3.4 tantalum standard stock solution

Weigh 0.1000g pure tantalum [(Ta) >=99.9%], placed in 100mL teflon beaker, add

5mL nitric acid (3.1), 5mL of hydrofluoric acid (3.2), cover sheet pan, over low heat until completely dissolved tantalum, removed, cooled to room temperature, transferred to

100mL plastic volumetric flask, dilute with water to volume, and mix. Store in plastic bottle. This solution 1mL containing 1.0mg tantalum.

3.5 niobium standard stock solution

Weigh 0.1000g pure niobium [(Nb) >=99.9%], placed in 100mL teflon beaker, add

5mL nitric acid (3.1), 5mL of hydrofluoric acid (3.2), cover sheet pan, over low heat until completely dissolved niobium, removed, cooled to room temperature, transferred to

100mL plastic volumetric flask, dilute with water to volume, and mix. Store in plastic bottle. This solution 1mL containing 1.0mg niobium.

3.6

tantalum and niobium mixed standard solution A. Pipette 10.00mL tantalum standard stock solution (3.4), 10.00mL niobium standard stock solution (3.5),

In 100mL plastic flask supplemented with 5mL of hydrofluoric acid (3.2) diluted with water to volume, and mix. Store in plastic bottle. This solution

1mL each containing 100µg and 100µg of tantalum and niobium.

3.7 tantalum and niobium mixed standard solution B

Pipette 10.00mL tantalum and niobium mixed standard solution A (3.6), in 100mL plastic flask, supplemented

5mL of hydrofluoric acid (3.2), diluted with water to volume, and mix. Store in plastic bottle. This solution 1mL containing 10µg respectively, and tantalum

10µg niobium.

4 Instrument

Inductively coupled plasma spectrometer, hydrofluoric acid resistant sample introduction system.

5 Sample

5.1

Sample size of less than 0.074mm.

5.2

sample was pretreated at 105 °C ~ 110 °C drying 2h, placed in a desiccator to cool to room temperature.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 6150.7

EditionTitleRevisionStatus
GB/T 6150.7-2008Methods for chemical analysis of tungsten concentrates - Determination of tantalum content and niobium content - Inductively coupled plasma emission spectrometry and spectrophotometrycurrent editionCurrent
GB/T 6150.9-1985Methods for chemical analysis of tungsten concentrates - Determination of tantalum content and niobium content - Inductively coupled plasma emission spectrometry and spectrophotometryprevious editionSuperseded

This page sells the current edition, GB/T 6150.7-2008. Earlier editions are listed for reference only.

How to Download GB/T 6150.7-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 6150.7-2008

$135.00