Valid

GB/T 6150.9-2009Methods for chemical analysis of tungsten concentrates - Determination of copper content - Flame atomic absorption spectrometry (English PDF)

钨精矿化学分析方法 铜量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 6150.9-2009 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 30, 2009

Implementation date

June 1, 2010

Scope

GB/T 6150.9-2009 is the English-translated version of 钨精矿化学分析方法 铜量的测定 火焰原子吸收光谱法.

GB/T 6150.9-2009 gives the flame atomic absorption spectrometric method for determining the copper content of tungsten concentrates. Clause 1 applies it to the determination of copper in tungsten concentrates over a measuring range of 0.005 % to 1.00 %.

GB/T 6150, Methods for chemical analysis of tungsten concentrates, is divided into 17 parts and this document is part 9.

The method summary has the sample decomposed with hydrochloric, nitric and perchloric acid, heated until dense white fumes come off, then cooled and taken up in a nitric acid medium, after which the absorbance of copper is measured on an atomic absorption spectrometer at a wavelength of 324.8 nm in an air-acetylene flame and the copper mass fraction is computed by the working curve method, the other impurities of the concentrate causing no interference.

The reagents clause lists hydrochloric, nitric and perchloric acid of stated density, nitric acid diluted 1+1, and a copper stock solution of 200 micrograms per millilitre prepared from 0.2000 g of copper of at least 99.99 % purity.

The instrument clause asks for a spectrometer with a copper hollow cathode lamp and sets the figures it must reach: a characteristic concentration for copper below 0.059 micrograms per millilitre in a solution matching the matrix of the test solution, precision limits on ten absorbance readings of the most and the least concentrated standard solutions, and a linearity check in which the curve is divided into five concentration segments and the ratio between the absorbance difference of the highest segment and that of the lowest must not fall below 0.7.

The remaining clauses cover the sample, ground below 0.074 mm and dried for two hours at 105 to 110 degrees C before being cooled in a desiccator, and the analysis steps, which start from the test portion weighed to 0.0001 g according to Table 1.

Against the edition it replaces, the analysis medium was changed from hydrochloric acid to nitric acid, the measuring range was widened from 0.005 % to 0.500 % up to 0.005 % to 1.00 %, the standard solution is prepared in nitric acid instead of hydrochloric and perchloric acid, and a repeatability clause was added.

It replaces GB/T 6150.11-1985, was issued on 2009-10-30 and has applied since 2010-06-01.

Found what you need?

Document preview — GB/T 6150.9-2009

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 63
Replacing
GB/T 6150.11-1985

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument
  • 5 Sample

Foreword

GB/T 6150 "Methods for chemical analysis of tungsten concentrates" is divided into 17 parts.

Determination of GB/T 6150.1 Methods for chemical analysis of tungsten concentrates of tungsten trioxide amount of ammonium tungstate burning gravimetric method

GB/T 6150.2 Methods for chemical analysis of tungsten concentrates - Determination of tin content of potassium iodate volumetric method and hydride generation atomic absorption spectrometry

GB/T 6150.3 Methods for chemical analysis of tungsten concentrates - Determination of phosphorus content of phosphorus molybdenum yellow spectrophotometry Determination of GB/T 6150.4 Methods for chemical analysis of tungsten concentrates sulfur content of high frequency infrared absorption method Determination of EDTA volumetric method and atomic GB/T 6150.5 Methods for chemical analysis of tungsten concentrates calcium absorption spectrometry

GB/T 6150.6 Methods for chemical analysis of tungsten concentrates - Determination of hygroscopic water gravimetric method

GB/T 6150.7 Methods for chemical analysis of tungsten concentrates - Determination of the amount of tantalum and niobium plasma emission spectroscopy and spectrophotometry

GB/T 6150.8 Methods for chemical analysis of tungsten concentrates - Determination of molybdenum content - Thiocyanate spectrophotometric

GB/T 6150.9 Methods for chemical analysis of tungsten concentrates - Determination of copper content - Flame atomic absorption spectrometry

GB/T 6150.10 Methods for chemical analysis of tungsten concentrates - Determination of lead content by flame atomic absorption spectrometry

GB/T 6150.11 Methods for chemical analysis of tungsten concentrates of zinc content - Flame Atomic Absorption Spectrometry

GB/T 6150.12 Methods for chemical analysis of tungsten concentrates - Determination of silicon dioxide content and weight of molybdenum blue spectrophotometric method Hydride atomic GB/T 6150.13 Methods for chemical analysis of tungsten concentrates the amount of arsenic absorption spectroscopy and spectroscopic DDTC-Ag Spectrophotometry

GB/T 6150.14 Methods for chemical analysis of tungsten concentrates - Determination of manganese content of ammonium ferrous sulfate volumetric method and flame atomic absorption spectrometry

GB/T 6150.15 Methods for chemical analysis of tungsten concentrates bismuth content - Flame Atomic Absorption Spectrometry

GB/T 6150.16 Methods for chemical analysis of tungsten concentrates - Determination of iron content sulfonic acid spectrophotometry Hydride atomic GB/T 6150.17 Methods for chemical analysis of tungsten concentrates antimony content absorption spectrometry This section Part 9 GB/T 6150's.

This Part replaces GB/T 6150.11-1985 "chemical analysis of tungsten concentrates - The atomic absorption spectrophotometric determination of copper content." Section compared with the GB/T 6150.11-1985 The main changes are as follows.

--- Assay medium with hydrochloric acid to nitric acid;

--- Expanded measurement range from 0.005 percent to 0.500 percent to 0.005% to 1.00%;

--- Standard solution by adding hydrochloric acid, perchloric acid was added to a solution of nitric acid;

--- Increased repeatability terms.

1 Scope

GB/T 6150 This section provides the determination of copper content of tungsten concentrates.

This section applies to the determination of copper content of tungsten concentrates. Measurement range. 0.005% to 1.00%.

2 Method summary

Sample in a boiling water bath to decompose hydrochloric acid, nitric acid, perchloric acid is heated to dissolve the thick white smoke to take, remove cooling, nitric acid, the nitrate Acid medium, atomic absorption spectrometer at a wavelength of 324.8nm, air - acetylene flame measured the absorbance of copper, calculated using the working curve method Copper quality scores. Tungsten concentrate of impurities did not interfere.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or relative purity of water.

3.1 hydrochloride (rho1.19g/mL).

3.2 Nitrate (rho1.42g/mL).

3.3 Perchloric acid (rho1.67g/mL).

3.4 nitric acid (1 + 1).

3.5 copper standard stock solution. Weigh 0.2000g pure copper [Cu>=99.99%] in 300mL beaker, add 100mL nitric acid (3.4), dissolved by heating, cooling and 1000mL flask in constant volume, mix, and this solution 1mL containing 200µg copper.

4 Instrument

Atomic absorption spectrometer, with copper hollow cathode lamp.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Characteristic concentration. In line with the measuring solution matrix solution features copper concentration should be less than 0.059µg/mL.

--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed 1.5% of the average absorbance;

With the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum The average concentration of 0.5% absorbance.

--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment Ratio should not be less than 0.7.

5 Sample

5.1 Sample size of less than 0.074mm.

5.2 sample was pretreated at 105 °C ~ 110 °C drying 2h, placed in a desiccator to cool to room temperature.

6 Analysis

6.1 Sample

Table 1 sample was weighed (accurate to 0.0001g). […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 6150

Similar standards

Editions of GB/T 6150.9

EditionTitleRevisionStatus
GB/T 6150.9-2009Methods for chemical analysis of tungsten concentrates - Determination of copper content - Flame atomic absorption spectrometrycurrent editionCurrent
GB/T 6150.11-1985Methods for chemical analysis of tungsten concentrates - Determination of copper content - Flame atomic absorption spectrometryprevious editionSuperseded

This page sells the current edition, GB/T 6150.9-2009. Earlier editions are listed for reference only.

How to Download GB/T 6150.9-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 6150.9-2009

$85.00