Valid

GB/T 45092-2024Testing and evaluation of electrodes performance for hydrogen production by water electrolysis (English PDF)

电解水制氢用电极性能测试与评价

Open the GB/T 45092-2024 preview as PDF

Preview — first pages of GB/T 45092-2024 (full document: 26 pages)

This is a limited preview

Buy now to download the full PDF (26 pages)

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

November 28, 2024

Implementation date

March 1, 2025

Scope

GB/T 45092-2024 is the English-translated version of 电解水制氢用电极性能测试与评价.

GB/T 45092-2024 sets the methods for testing and evaluating the electrodes used in water electrolysis for hydrogen production. In an alkaline electrolyser the electrode is the component that decides both the energy cost of the hydrogen and the life of the stack, and China is installing electrolysers faster than anywhere else, increasingly coupled to wind and solar whose output swings - which is the condition under which coatings delaminate and reverse-current damage occurs. The standard describes the test and evaluation indicators and then the methods: the ultrasonic weight loss test for coating adhesion, the overpotential test, the positive and negative polarisation stability, the average cell voltage and its rate of change, and electrolysis under fluctuating current, each with its principle, reagents, equipment, samples, test conditions, test steps and data processing. It takes effect on 1 March 2025.

Document preview — GB/T 45092-2024

National Standard of the People's Republic of China

ICS
27.010
Classification
F19

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword...4
  • 1 Scope...5
  • 2 Normative references...5
  • 3 Terms and definitions...6
  • 4 Test and evaluation indicators...6
  • 5 Ultrasonic weight loss test...7
  • 5.1 Principle...7
  • 5.2 Reagents...7
  • 5.3 Equipment...7
  • 5.4 Sample...8
  • 5.5 Test conditions...8
  • 5.6 Test steps...8
  • 5.7 Data processing...9
  • 6 Overpotential test...9
  • 6.1 Principle...9
  • 6.2 Reagents...10
  • 6.3 Equipment...10
  • 6.4 Samples...12
  • 6.5 Reference electrode...12
  • 6.6 Counter electrode...13
  • 6.7 Test conditions...13
  • 6.8 Test steps...13
  • 6.9 Data processing...14
  • 7 Positive and negative polarization stability test...14
  • 7.1 Principle...14
  • 7.2 Reagents...15
  • 7.3 Equipment...15
  • 7.4 Sample...15
  • 7.5 Reference electrode and counter electrode...15
  • 7.6 Test conditions...15
  • 7.7 Test steps...15
  • 7.8 Data processing...16
  • 8 Test of average cell voltage and average cell voltage change rate...16
  • 8.1 Principle...16
  • 8.2 Reagents...17
  • 8.3 Equipment...17
  • 8.4 Sample...18
  • 8.5 Test conditions...18
  • 8.6 Test steps...19
  • 8.7 Data processing...19
  • 9 Fluctuating current electrolysis test...20
  • 9.1 Principle...20
  • 9.2 Reagents, equipment, samples, test conditions...21
  • 9.3 Test steps...21
  • 9.4 Data processing...22

1 Scope

GB/T 45092-2024 sets the methods for testing and evaluating the electrodes used in water electrolysis for hydrogen production. In an alkaline electrolyser the electrode is the component that decides both the energy cost of the hydrogen and the life of the stack, and China is installing electrolysers faster than anywhere else, increasingly coupled to wind and solar whose output swings - which is the condition under which coatings delaminate and reverse-current damage occurs. The standard describes the test and evaluation indicators and then the methods: the ultrasonic weight loss test for coating adhesion, the overpotential test, the positive and negative polarisation stability, the average cell voltage and its rate of change, and electrolysis under fluctuating current, each with its principle, reagents, equipment, samples, test conditions, test steps and data processing. It takes effect on 1 March 2025.

This document describes the test and evaluation methods for ultrasonic weight loss, overpotential, positive and negative polarization stability, average cell voltage, average cell voltage change rate, fluctuating current electrolysis of electrodes for hydrogen production by water electrolysis. This document is applicable to the performance test and evaluation of electrodes for hydrogen production by alkaline water electrolysis. The hydrogen evolution electrode and oxygen evolution electrode for hydrogen production by hydroxyl ion exchange membrane water electrolysis shall be implemented with reference to this document.

2 Normative references

The contents of the following documents constitute essential clauses of this document through normative references in the text. Among them, for dated references, only the version corresponding to that date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document.

GB/T 678 Chemical reagent - Ethanol

GB/T 2306 Chemical reagent - Potassium hydroxide

GB/T 2900.98 Electrotechnical terminology - Electrochemistry

GB/T 3634.2 Hydrogen - Part 2: Pure hydrogen, high pure hydrogen and ultrapure hydrogen

GB/T 6682 Water for analytical laboratory use - Specification and test methods

GB/T 14599 Pure oxygen and high purity oxygen and ultra-pure oxygen

GB/T 15724 Laboratory glassware beaker

GB/T 21648 Industrial dense woven wire cloth

GB/T 28817 Single cell test methods for polymer electrolyte fuel cell (PEFC)

3 Terms and definitions

The terms and definitions defined in GB/T 2900.98, as well as the following terms and definitions, apply to this document.

3.1 Overpotential The absolute value of the difference between the working potential and the theoretical potential, when an electrode reaction occurs on the electrode.

Note: The overpotential must indicate the corresponding current density. The working potential and theoretical potential are values relative to the same reference system.

3.2 Average cell voltage The average cell voltage in a certain period of time when electrolysis is carried out at a certain current density.

Note: For a single-cell electrolyzer, the average cell voltage is the average electrolyzer voltage in a certain period of time; for a multi-cell electrolyzer, it is the value obtained by dividing the average electrolyzer voltage in a certain period of time by the number of cells in series.

3.3 Reversible hydrogen electrode When hydrogen is introduced into a solution of a certain pH and reaches saturation, the electrode where the redox reaction of hydrogen and hydrogen ions on the platinum electrode reaches equilibrium and which has a balanced electrode potential.

Note: The potential of the reversible hydrogen electrode is related to pH. The potential of the reversible hydrogen electrode at 25°C is E=-0.0592pH.

4 Test and evaluation indicators

See Table 1 for electrode performance test and evaluation requirements.

5 Ultrasonic weight loss test...

5.4 Sample

5.4.1 Specifications The test electrode is a 40 mm × 40 mm rectangle. A set of test electrodes has 3 pieces; the 3 pieces shall come from the same batch of electrodes. For electrodes that need to be activated, the activated electrodes shall be used for testing.

5.4.2 Sample preparation The samples shall be cut according to the specifications of the test electrodes, with a size error of less than 2%. After cutting, the electrodes shall be kept flat; the burrs, serrations or sharp protrusions on the edges of the electrodes shall be rounded.

5.5 Test conditions The temperature of the test liquid in the ultrasonic cleaning machine is 30 °C ± 1 °C.

5.6 Test steps The test steps for ultrasonic weight loss of electrodes are as follows:

a) Treatment: Rinse the electrodes repeatedly with pure water for at least 3 times; then rinse the electrodes repeatedly with anhydrous ethanol (unless otherwise specified in this document, anhydrous ethanol shall comply with the analytical grade requirements in GB/T 678) for at least 3 times; dry the electrodes in a vacuum oven at 70 °C and a vacuum degree of no more than 200 Pa for more than 2 hours.

b) Weighing: Weigh 3 electrodes in turn; record the initial mass mi,0 of the 3 electrodes respectively, with an accuracy of

0.1 mg.

c) Ultrasonic treatment: Treat one electrode each time; place the electrode horizontally at the bottom of a 250 mL glass beaker containing 200 mL of test solution (unless otherwise specified in this document, the glass beaker shall comply with the specification of 250 mL nominal capacity in GB/T 15724); place the beaker at the bottom of the ultrasonic cleaning machine and fix it; add water to the ultrasonic cleaning machine until the water level in the inner tank is 50 mm; treat it continuously for 60 min at a temperature of 30 °C ± 1 °C. The sample placement position during ultrasonic weight loss test is shown in Figure 1.

d) Take out the test electrode; treat and weigh the post-ultrasonic electrode according to the steps described in

a) and b); record the final mass mi of the three electrodes, respectively. electrode with an external salt bridge. Before use, the reference electrode shall be calibrated for potential according to the method described in Appendix A.

6.6 Counter electrode The counter electrode is a pure nickel electrode with a purity of not less than 99.5% and an effective size of 30 mm × 30 mm.

6.7 Test conditions The electrode overpotential test conditions are as follows:

a) The test solution temperature is controlled at 25.0 °C ± 0.5 °C.

b) When measuring the hydrogen evolution electrode, the test solution is continuously filled with hydrogen to maintain a saturated state; when measuring the oxygen evolution electrode, the test solution is continuously filled with oxygen to maintain a saturated state. Unless otherwise specified in this document, the oxygen used shall comply with the provisions of high purity oxygen in GB/T 14599; the hydrogen shall comply with the provisions of high purity hydrogen in GB/T 3634.2.

7 Positive and negative polarization stability test...

7.3 Equipment

7.3.1 The test of positive and negative polarization stability adopts two-electrode test system and three-electrode test system. The test system shall comply with the provisions of 6.3.1, but the two-electrode test system does not contain a reference electrode.

7.3.2 Electrochemical performance tester, electrolytic cell, constant temperature heating pot shall comply with the relevant provisions of 6.3.

7.4 Sample The test electrode shall comply with the provisions of 6.4.

7.5 Reference electrode and counter electrode The reference electrode shall comply with the provisions of 6.5. The counter electrode shall comply with the provisions of 6.6.

7.6 Test conditions The test conditions shall comply with the relevant provisions of 6.7.

7.7 Test steps The steps for the positive and negative polarization stability test are as follows:

a) In the three-electrode test system, measure the overpotential etai,0 of each test electrode before positive and negative polarization according to the provisions of 6.8;

Note: The single-cell electrolyzer is a normal pressure electrolyzer.

8.3.4 Alkali circulation pump The flow rate of the alkali circulation pump should be

0.5 L/min.

8.3.5 Rehydration pump The flow rate of the rehydration pump is not less than 20 mL/h.

8.3.6 Gas-liquid separator The material of the gas-liquid separator is polypropylene, polytetrafluoroethylene, carbon steel nickel-plated or 316 L stainless steel.

8.4 Sample The test electrode shall meet the following requirements:

a) The electrode shape is rectangular, the size is 50 mm × 40 mm, the length and width size errors are <= ±1 mm; the actual size of the electrode is measured with a vernier caliper;

8 Test of average cell voltage and average cell voltage change rate...

8.7 Data processing

8.7.1 Average cell voltage change rate The average voltage change rate of the cell is calculated according to formula (4): Where: vd - Average cell voltage change rate, in microvolts per hour (µV/h); t - Continued operation time after 72 hours of operation, in hours (h);

Appendix A

(Normative) Electrode potential calibration of reference electrode A.1 Principle A three-electrode test system is used, with high-purity Pt sheets as test electrodes and counter electrodes; the electrode to be calibrated is used as the reference electrode. During the calibration process, hydrogen is introduced into the test solution to maintain it in a saturated state; then the multi-cycle cyclic voltammetry curve is tested at a rate of 1 mV/s. The value of the electrode to be calibrated is calculated based on the potential value of the zero current in the cyclic voltammetry curve. A.2 Calibration reagents, equipment, electrodes A.2.1 Reagents shall comply with the provisions of 6.2. A.2.2 Equipment shall comply with the provisions of 6.3. A.2.3 The electrodes used in calibration shall meet the following requirements:

a) The test electrode is a Pt electrode, which has a purity higher than 99.9%; the effective size of the electrode is 10 mm × 10 mm;

b) The reference electrode is the electrode to be calibrated, which is a mercury/mercury oxide electrode or a saturated calomel electrode with an external salt bridge;

c) The counter electrode is a Pt electrode, which has a purity higher than 99.9% and an effective size of 20 mm × 20 mm. A.3 Calibration steps The reference electrode calibration steps are as follows:

a) Power on and preheat: 10 minutes before starting the test, turn on the power of the electrochemical performance tester for preheating;

b) Inflation: Adjust the gas flow rate to 50 mL/min; fill the test solution with hydrogen until saturated. The hydrogen used shall meet the technical requirements of high-purity hydrogen in GB/T 3634.2;

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 26 pages — is available in the English PDF.

Referenced standards

Similar standards

GB 38031-2025|GB/T 678|GB/T 2306|GB/T 2900.98|GB/T 3634.2|GB/T 6682|GB/T 14599|GB/T 15724

How to Buy GB/T 45092-2024

  1. 1Add to cart. Click the "Buy GB/T 45092-2024" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
26 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 45092-2024

$335.00

$285.00for partners