Valid

GB/T 4372.4-2015Methods for chemical analysis of zincoxide produced by direct process - Part 4: Determination of cadmium oxide content - Flame atomic absorption spectrometry method (English PDF)

直接法氧化锌化学分析方法 第4部分:氧化镉量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 4372.4-2015 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

September 11, 2015

Implementation date

April 1, 2016

Scope

GB/T 4372.4-2015 is the English-translated version of 直接法氧化锌化学分析方法 第4部分:氧化镉量的测定 火焰原子吸收光谱法.

GB/T 4372.4-2015 is the Chinese standard "Methods for chemical analysis of zincoxide produced by direct process - Part 4: Determination of cadmium oxide content - Flame atomic absorption spectrometry method".

Its scope clause reads: This part of GB/T 4372 specifies the method for the determination of cadmium oxide in direct zinc oxide. This part applies to the determination of cadmium oxide in direct zinc oxide.

Measuring range. 0.0020% ~ 0.300%. Its clauses include method summary; reagent; instruments; samples.

Found what you need?

Document preview — GB/T 4372.4-2015

National Standard of the People's Republic of China

ICS
77.120.60
Classification
H 13
Replacing
GB/T 4372.4-2001

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 method summary
  • 3 reagent
  • 4 instruments
  • 5 samples

1 Scope

This part of GB/T 4372 specifies the method for the determination of cadmium oxide in direct zinc oxide.

This part applies to the determination of cadmium oxide in direct zinc oxide. Measuring range. 0.0020% ~ 0.300%.

2 method summary

The sample was dissolved in nitric acid and used in a dilute nitric acid medium using an air-acetylene flame at a wavelength of 228.8 nm at the atomic absorption spectrometer

Cadmium absorbance, the standard curve method to calculate the amount of cadmium oxide.

3 reagent

Unless otherwise stated, only the reagents identified as analytical reagents and distilled or deionized water or comparable purity were used in the analysis.

3.1

nitric acid (rho = 1.42 g/mL).

3.2

nitric acid (1 1).

3.3 Cadmium standard storage solution

Weigh 1.0000g metal cadmium (wCd >= 99.99%) placed in 250mL beaker, add 10mL nitric acid (3.2), slightly heat dissolved, remove the cooling, into the 1000mL volumetric flask, add 40mL nitric acid (3.2), diluted with water to the mark, mix.

1 mL of this solution contains 100 µg of cadmium.

3.4 Cadmium standard solution

Remove 10.00mL cadmium standard storage solution (3.3) in 100mL volumetric flask, add 5mL nitric acid (3.2), with

Water diluted to the mark, mix well. 1 mL of this solution contains 10 µg of cadmium, respectively

4 instruments

Atomic Absorption Spectrometer, Cadmium Hollow Cathode Lamp.

In the best working conditions of the instrument, who can meet the following indicators can be used.

Sensitivity. The concentration of copper and cadmium should not be greater than 0.035 µg/mL in solutions consistent with the measurement sample solution matrix.

Precision. the highest concentration of the standard solution measured 10 times the absorbance, the standard deviation should not exceed 1.0% of the average absorbance; with the most

Low standard solution (not zero standard solution) measured 10 times the absorbance, the standard deviation does not exceed the maximum concentration of standard solution average absorbance

0.5% of the degree.

The linearity of the working curve. the ratio of the difference between the absorbance difference and the absorbance difference of the lowest section is divided into five segments according to the concentration,

Should not be less than 0.7.

5 samples

5.1

Specimen size should be less than 0.10mm.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 4372.4

EditionTitleRevisionStatus
GB/T 4372.4-2015Methods for chemical analysis of zincoxide produced by direct process - Part 4: Determination of cadmium oxide content - Flame atomic absorption spectrometry methodcurrent editionCurrent
GB/T 4372.4-2001Methods for chemical analysis of zincoxide produced by direct process - Part 4: Determination of cadmium oxide content - Flame atomic absorption spectrometry methodprevious editionSuperseded

This page sells the current edition, GB/T 4372.4-2015. Earlier editions are listed for reference only.

How to Download GB/T 4372.4-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 4372.4-2015