Valid

GB/T 4372.5-2014Methods for chemical analysis of zinc oxide produced by direct process - Part 5: Determination of manganese content - Flame atomic absorption spectrometry method (English PDF)

直接法氧化锌化学分析方法 第5部分:锰量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 4372.5-2014 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 5, 2014

Implementation date

August 1, 2015

Scope

GB/T 4372.5-2014 is the English-translated version of 直接法氧化锌化学分析方法 第5部分:锰量的测定 火焰原子吸收光谱法.

GB/T 4372.5-2014 is the Chinese standard "Methods for chemical analysis of zinc oxide produced by direct process - Part 5: Determination of manganese content - Flame atomic absorption spectrometry method".

Its scope clause reads: GB/T 4372 provisions of this part of the determination of the direct method zinc oxide manganese content. This section applies to the determination of the direct method zinc oxide manganese content.

Determination range of 0.0001% to 0.0010%. Its clauses include method summary; reagents and materials; instrument.

Found what you need?

Document preview — GB/T 4372.5-2014

National Standard of the People's Republic of China

ICS
77.120.60
Classification
H 13
Replacing
GB/T 4372.5-2001

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Method summary
  • 3 Reagents and materials
  • 4 Instrument

1 Scope

GB/T 4372 provisions of this part of the determination of the direct method zinc oxide manganese content.

This section applies to the determination of the direct method zinc oxide manganese content. Determination range of 0.0001% to 0.0010%.

2 Method summary

Sample dissolved in nitric acid, ferric hydroxide as a co-precipitating agent, a large number of trace manganese and zinc substrate separated and enriched, atomic test solution

Absorption spectrometer wavelength 279.5nm measured absorbance in the working curve method for the determination of manganese content.

3 Reagents and materials

Unless otherwise indicated in the analysis using only recognized as analytical reagents; the water is deionized water, the resistivity of not less than 18.2Mohm.

3.1

ammonium persulfate.

Nitrate 3.2 (rho1.42g/mL).

3.3

Hydrogen peroxide (rho1.44g/mL).

3.4

ammonia.

3.5

nitric acid (11).

3.6

nitric acid (19).

Hydrogen peroxide 3.7 - nitrate mixture. 100mL nitric acid (3.6) was added 5mL of hydrogen peroxide (3.3).

3.8 ferric chloride solution

Weigh 1.43g ferric chloride in 300mL beaker with water wet, add 30mL of nitric acid (3.5), to be dissolved completely shifted

500mL flask, washed with water several times a beaker and poured into a volumetric flask, dilute to the mark, and mix the solution 1mL iron 2.0mg.

3.9 manganese standard stock solution

Weigh 0.1000g of manganese metal (wMn>=99.99%), placed in 300mL beaker, add 20mL of nitric acid (3.5), and heated to dissolve completely cooled. Moved into 1000mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 100µg manganese.

3.10 Manganese standard solution

Pipette 2.5mL manganese standard stock solution (3.9) in 100mL volumetric flask, dilute with water to volume, and mix. this

Solution 1mL manganese 2.5µg.

4 Instrument

Atomic absorption spectrometer, with a manganese hollow cathode lamp.

Under optimum working conditions, can be achieved by the following indicators can be used.

Sensitivity. In line with the measurement sample solution matrix solution, characteristic concentration of manganese should not exceed 0.020µg/mL.

Precision. measuring the absorbance at 10 times the highest concentration of the standard solution, the standard deviation should not exceed the average absorbance of 1.0%; most

Low concentrations of the standard solution (not a zero standard solution) absorbance measured 10 times, and the standard deviation should not exceed the mean absorbance of the highest concentration of the standard

0.5% luminosity.

Linear curve. The curve is divided into five sections according to concentration, than the difference between the absorbance of the absorbance difference between the highest and the lowest segment segment,

It should not be less than 0.7.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 4372.5

EditionTitleRevisionStatus
GB/T 4372.5-2014Methods for chemical analysis of zinc oxide produced by direct process - Part 5: Determination of manganese content - Flame atomic absorption spectrometry methodcurrent editionCurrent
GB/T 4372.5-2001Methods for chemical analysis of zinc oxide produced by direct process - Part 5: Determination of manganese content - Flame atomic absorption spectrometry methodprevious editionSuperseded

This page sells the current edition, GB/T 4372.5-2014. Earlier editions are listed for reference only.

How to Download GB/T 4372.5-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.