Valid

GB/T 4324.15-2008Methods for chemical analysis of tungsten - Determination of magnesium content - The flame atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry (English PDF)

钨化学分析方法 镁量的测定 火焰原子吸收光谱法和电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 4324.15-2008 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 9, 2008

Implementation date

December 1, 2008

Scope

GB/T 4324.15-2008 is the English-translated version of 钨化学分析方法 镁量的测定 火焰原子吸收光谱法和电感耦合等离子体原子发射光谱法.

GB/T 4324.15-2008 is the Chinese standard "Methods for chemical analysis of tungsten - Determination of magnesium content - The flame atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry".

Its scope clause reads: This method provides for the determination of tungsten powder, tungsten trioxide, tungsten, tungsten blue, purple tungsten, tungsten carbide, tungsten acid, ammonium metatungstate, ammonium paratungstate magnesium content method.

This method is suitable for tungsten powder, tungsten measure, tungsten trioxide, tungsten blue, purple tungsten, tungsten carbide, tungsten acid, ammonium metatungstate, ammonium paratungstate magnesium content set.

Measurement range. 0.0003% to 0.050%. Its clauses include method summary; reagents; instrument.

Found what you need?

Document preview — GB/T 4324.15-2008

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 63
Replacing
GB/T 4324.15-1984

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument

1 Scope

This method provides for the determination of tungsten powder, tungsten trioxide, tungsten, tungsten blue, purple tungsten, tungsten carbide, tungsten acid, ammonium metatungstate, ammonium paratungstate magnesium content method.

This method is suitable for tungsten powder, tungsten measure, tungsten trioxide, tungsten blue, purple tungsten, tungsten carbide, tungsten acid, ammonium metatungstate, ammonium paratungstate magnesium content set. Measurement range. 0.0003% to 0.050%.

2 Method summary

Tungsten powder, tungsten bar, fine (in) tungsten carbide particles with hydrogen peroxide decomposition; blue tungsten with hydrogen peroxide and ammonia decomposition; tungsten oxide, tungstate, paratungstate

Ammonium metatungstate aqueous ammonia decomposition; purple tungsten, tungsten carbide coarse particles after firing into tungsten trioxide with ammonia decomposition. Hydrogen peroxide, citric acid complex

Co-tungsten, determination of magnesium content in atomic absorption spectrometer.

3 Reagents

Unless otherwise indicated, used in the analysis confirmed only for the gifted class pure reagents and double distilled water.

3.1

Hydrogen peroxide (rho1.10g/mL).

Ammonia 3.2 (1 + 1).

3.3

citric acid solution (500g/L).

3.4 Magnesium standard stock solution

Weigh 0.1658g pre 1h burning magnesium oxide by 780 °C (magnesium oxide content of not less than

99.99%), placed in a beaker of 250mL, was added 20mL of hydrochloric acid (1 + 1), low dissolved with heating, cooled to room temperature. The solution was transferred to

1000mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 100µg magnesium.

3.5 Magnesium standard solution

Pipette 10.00mL magnesium standard stock solution (3.4) into 100mL volumetric flask, dilute to the mark with water, mix uniform. This solution 1mL containing 10µg magnesium.

3.6 tungsten substrate

magnesium content is less than 0.0001%.

4 Instrument

Atomic absorption spectrometer, with a magnesium hollow cathode lamp.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Characteristic concentration. in the solution was measured and consistent substrate solution, wherein the concentration of magnesium is not more than 0.01µg/mL.

--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed 1.5% of the average absorbance;

With the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum

The average concentration of 0.5% absorbance.

--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment

Ratio should not be less than 0.7.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 4324.15

EditionTitleRevisionStatus
GB/T 4324.15-2008Methods for chemical analysis of tungsten - Determination of magnesium content - The flame atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometrycurrent editionCurrent
GB/T 4324.15-1984Methods for chemical analysis of tungsten - Determination of magnesium content - The flame atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometryprevious editionSuperseded

This page sells the current edition, GB/T 4324.15-2008. Earlier editions are listed for reference only.

How to Download GB/T 4324.15-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 4324.15-2008

$105.00