GB/T 4324.13-2008Methods for chemical analysis of tungsten - Determination of calcium content - The inductively coupled plasma atomic emission spectrometry (English PDF)

钨化学分析方法 钙量的测定 电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 4324.13-2008 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 9, 2008

Implementation date

December 1, 2008

Scope

GB/T 4324.13-2008 is the English-translated version of 钨化学分析方法 钙量的测定 电感耦合等离子体原子发射光谱法.

GB/T 4324.13-2008 is the Chinese standard "Methods for chemical analysis of tungsten - Determination of calcium content - The inductively coupled plasma atomic emission spectrometry".

Its scope clause reads: This section provides tungsten powder, tungsten, tungsten trioxide determination, tungsten blue, purple tungsten, tungsten carbide, tungsten acid, ammonium paratungstate, metatungstate calcium content method.

This Part applies to tungsten powder, tungsten measure, tungsten trioxide, tungsten blue, purple tungsten, tungsten carbide, tungsten acid, ammonium paratungstate, metatungstate calcium content set.

Measurement range. 0.0003% to 0.050%. Its clauses include method summary; reagents; instrument; sample.

Found what you need?

Document preview — GB/T 4324.13-2008

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 63
Replacing
GB/T 4324.14-1984

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument
  • 5 Sample

1 Scope

This section provides tungsten powder, tungsten, tungsten trioxide determination, tungsten blue, purple tungsten, tungsten carbide, tungsten acid, ammonium paratungstate, metatungstate calcium content method.

This Part applies to tungsten powder, tungsten measure, tungsten trioxide, tungsten blue, purple tungsten, tungsten carbide, tungsten acid, ammonium paratungstate, metatungstate calcium content set. Measurement range. 0.0003% to 0.050%.

2 Method summary

Tungsten powder, tungsten bar, fine (in) tungsten carbide particles with hydrogen peroxide decomposition; blue tungsten with hydrogen peroxide and ammonia decomposition; tungsten oxide, tungstate, paratungstate

Ammonium metatungstate aqueous ammonia decomposition; purple tungsten, tungsten carbide coarse particles after the oxidation of the tungsten trioxide with ammonia decomposition. Hydrogen peroxide, citric acid complex

Together tungsten, in the determination of calcium inductively coupled plasma atomic emission spectrometer.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical reagents and double distilled water.

3.1

Hydrogen peroxide (rho1.10g/mL).

Ammonia 3.2 (1 + 1), the preparation of a MOS ammonia level.

3.3

citric acid solution (500g/L).

3.4 Calcium standard stock solution

Weigh 0.1399g pre-burning calcium oxide 1h through 900 °C (calcium oxide content of not less than

99.99%), placed in a beaker of 250mL, was added 20mL of hydrochloric acid (1 + 1), covered with a watch glass and heated until completely dissolved and cooled to room temperature.

The solution is transferred to 1000mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 100µg calcium.

3.5 Calcium standard solution

Pipette 10.00mL calcium standard stock solution (3.4) in 100mL volumetric flask, dilute with water to volume, and mix.

This solution 1mL containing 10µg calcium.

3.6 tungsten substrate

calcium mass fraction of less than 0.0001%.

4 Instrument

Inductively coupled plasma atomic emission spectrometer.

5 Sample

5.1

tungsten and shall crush through 125µm sieve.

5.2

average particle size of the tungsten carbide fine particles 1µm ~ 3µm, the average particle size of the tungsten carbide particles is greater than 3µm ~ 9µm, coarse WC particles

The average particle size greater than 9µm.

Step 6 Analysis

6.1 Sample

Weigh 0.5g ~ 1g sample (5), accurate to 0.0001g.

6.2

Determination of the number of

Independently measured twice and averaged.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 4324.13

EditionTitleRevisionStatus
GB/T 4324.13-2008Methods for chemical analysis of tungsten - Determination of calcium content - The inductively coupled plasma atomic emission spectrometrycurrent editionCurrent
GB/T 4324.14-1984Methods for chemical analysis of tungsten - Determination of calcium content - The inductively coupled plasma atomic emission spectrometryprevious editionSuperseded

This page sells the current edition, GB/T 4324.13-2008. Earlier editions are listed for reference only.

How to Download GB/T 4324.13-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 4324.13-2008

$109.00