Scope
GB/T 41800-2022 is the English-translated version of 信息技术 传感器网络 爆炸危险化学品贮存安全监测系统技术要求.
GB/T 41800-2022 sets out what a sensor-network system for monitoring the safety of explosive hazardous chemicals in storage has to do and what it is built from.
It fixes the functional and the technical architecture, then the functional requirements for the perception and control domain, the service provider domain, the resource exchange domain and the operation and maintenance control domain, and the technical requirements for the perception devices, the IoT gateway, the platform, the terminal equipment and data security.
It applies to building such systems at explosive hazardous chemical storage units, tank areas and storage areas, that count as major hazard sources. Among the standards it quotes are GB 18218-2018, GB/T 22239-2019 and GB/T 50493-2019. Issued on 14 October 2022, it has applied since 1 May 2023.
Found what you need?
Document preview — GB/T 41800-2022
National Standard of the People's Republic of China
- ICS
- 35.110
- Classification
- L 77
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Abbreviations
- 5 System Architecture
- 5.1 Functional Architecture
- 5.2 Technical Architecture
- 6 Functional Requirements
- 6.1 Perception Control Domain
- 6.2 Service Provider Domain
- 6.3 Resource Exchange Domain
- 6.4 O&M Control Domain
- 7 Technical Requirements
- 7.1 Perception device
- 7.2 IoT Gateway
- 7.3 Platform
- 7.4 Terminal equipment
- 7.5 Data Security
- Reference
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted.
1 Scope
This document specifies the architecture, functional requirements and technical requirements of the storage safety monitoring system for explosive hazardous chemicals (hereinafter referred to as the "system").
This document is applicable to the safety monitoring system of explosive hazardous chemical storage units (tank areas, reservoir areas) that are major hazard sources of hazardous chemicals system construction.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.
GB 18218-2018 Identification of Major Hazardous Sources of Hazardous Chemicals
GB/T 22239-2019 Basic requirements for classified protection of information security technology network security
GB/T 50493-2019 Petrochemical flammable and toxic gas detection and alarm design standards
HG/T 20507-2014 Specification for selection and design of automatic instrumentation
HG/T 21581-2012 Automatic Control Installation Atlas
SH/T 3005-2016 Specification for selection and design of petrochemical automation instruments
SH/T 3104-2013 Specification for installation and design of petrochemical instruments
3 Terms and Definitions
The terms and definitions defined in GB 18218-2018 and the following terms and definitions apply to this document.
3.1 Hazardous chemicals
Highly toxic chemicals and other chemicals that have the properties of toxicity, corrosion, explosion, combustion and combustion support, and are harmful to human body, facilities and the environment. [Source: GB 18218-2018, 3.1]
3.2 Explosive hazardous chemicals
Chemicals with potential explosion risk properties such as explosion and combustion, combustion support, and self-reaction, which are harmful to human body, facilities and the environment.
3.3 Storage unit
A relatively independent area composed of storage tanks or warehouses used to store hazardous chemicals, and the storage tank area is divided into independent areas with the tank area fire dike as the boundary.
The warehouse is divided into independent units with the independent warehouse (independent building) as the boundary. [Source: GB 18218-2018, 3.6]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 18218-2018Identification of major hazard installations for hazardous chemicals
- GB/T 22239-2019Information security technology - Baseline for classified protection of cybersecurity
- GB/T 50493-2019Specification for design of combustible gas and toxic gas detection and alarm for petrochemical industry
- HG/T 21581-2012Instrument hook-up drawings (Volumes I and II)
- SH/T 3005-2016Design specification for instrumentation selection in petrochemical industry
HG/T 20507-2014 · SH/T 3104-2013
Similar standards
How to Download GB/T 41800-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 18218-2018 — Identification of major hazard installations for hazardous chemicals
GB/T 22239-2019 — Information security technology - Baseline for classified protection of cybersecurity
GB/T 50493-2019 — Specification for design of combustible gas and toxic gas detection and alarm for petrochemical industry
Secure payment via Stripe
Payments accepted
GB/T 41800-2022
$210.00