Valid

GB/T 41783-2022General specification for modular data centers (English PDF)

模块化数据中心通用规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for GB/T 41783-2022 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 14, 2022

Implementation date

May 1, 2023

Scope

GB/T 41783-2022 is the English-translated version of 模块化数据中心通用规范.

GB/T 41783-2022 sets out the composition, categories and classes of modular data centers and specifies their technical requirements, test methods and the identification, packaging, transportation and storage.

It applies to the design, manufacture, installation and application of modular data centers.

The technical requirements cover the energy efficiency level, the cabinet and channel system, the refrigeration, power distribution, power supply, integrated monitoring, lighting, generic cabling and lightning protection and grounding systems, and the site and its environment, with a matching inspection and test method for each.

The document defines the modular data center, the channel system that closes the cold or hot aisle together with the cabinet, and redundancy. Clause 2 cites twelve documents, among them GB/T 2887-2011, GB 7000.1, GB 8624, GB/T 22690 and GB 51215. It was issued on 14 October 2022 and has applied since 1 May 2023.

Found what you need?

Document preview — GB/T 41783-2022

National Standard of the People's Republic of China

ICS
35.020
Classification
L 73

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Components of a Modular Data Center
  • 5 Modular data center classification and classification
  • 5.1 Category
  • 5.2 Class
  • 6 Technical Requirements
  • 6.1 Energy Efficiency Level Requirements
  • 6.2 Cabinet and Channel System Requirements
  • 6.3 Refrigeration system requirements
  • 6.4 Power distribution system requirements
  • 6.5 Power supply system requirements
  • 6.6 Integrated Monitoring System Requirements
  • 6.7 Lighting system requirements
  • 6.8 General wiring system requirements
  • 6.9 Lightning protection and grounding system requirements
  • 6.10 Site Selection and Environmental Requirements
  • 7 Test methods
  • 7.1 Test environment
  • 7.2 Energy Efficiency Test
  • 7.3 Cabinet and channel inspection and test
  • 7.4 Refrigeration system inspection and test
  • 7.5 Power distribution system inspection and test
  • 7.6 Inspection and test of power supply system
  • 7.7 Comprehensive monitoring system inspection and test
  • 7.8 Inspection and test of lighting system
  • 7.9 General wiring system inspection and test
  • 7.10 Inspection and test of lightning protection and grounding system
  • 7.11 Site Deployment Environment Inspection and Test
  • 8 Identification, packaging, transportation, storage

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted.

1 Scope

This document proposes the composition classification and classification of modular data centers, specifies technical requirements, test methods and identification, packaging, transportation, storage requirements.

This document applies to the design, manufacture, installation and application of modular data centers.

2 Normative references

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.

GB/T 191 Graphical signs of packaging, storage and transportation

GB/T 2887-2011 General Specification for Computer Fields

GB/T 5267.4 Fastener Surface Treatment Corrosion Resistant Stainless Steel Passivation Treatment

GB 7000.1 Lamps Part 1: General Requirements and Tests

GB 8624 Classification of Combustion Properties of Building Materials and Products

GB/T 8923 (all parts) Visual assessment of surface cleanliness of steel surface preparation before coating

GB/T 14295 Air filter

GB/T 18455 Packaging Recycling Mark

GB/T 22690 General Mechanical Structure Cabinets and Subracks for Data Communication Equipment

GB/T 26125 Determination of six restricted substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls and polybrominated diphenyl ethers) in electrical and electronic products

GB/T 26572 Limit Requirements for Restricted Substances in Electrical and Electronic Products

GB 51215 Specification for Engineering Design of Communication High Voltage DC Power Supply Equipment

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Modular data center

Installed in a building, it is composed of modular functional modules, and the building provides a data center with supporting facilities for electronic information design. The backup system provides services.

3.2 Channel system

It cooperates with the cabinet to form the components that close the cold/hot aisle, mainly including aisle doors, skylights, bases, etc.

3.3 Redundancy

The key components of the function module are repeatedly configured to share the system load. When some of the key components fail, the repeatedly configured The component supplements the load borne by the faulty component to ensure the normal operation of the functional module.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 41783-2022

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 41783-2022

$300.00