GB/T 41682-2022 is the English-translated version of 食品塑料包装容器中顶空气体含量的测定 传感器法.
GB/T 41682-2022 describes a sensor method for measuring the headspace gas in a plastic food package. It sets out the principle, sample preparation, the instrument, its calibration, the test procedure, the results and the report.
The instrument is built from a sampler, a sealing gasket, a sample injection port, a sensor whose detection accuracy does not exceed 0,5 % volume fraction, and a pipeline that carries the sample gas.
Calibration uses 99,99 % nitrogen for the zero point, 25 %, 10 % or 3 % carbon dioxide for the three sensor ranges, and 21 % oxygen for the oxygen sensor. Testing is done at 23 °C ± 2 °C and 50 % ± 10 % relative humidity.
It cites GB/T 2918 and ISO 2602:1980, was issued on 14 October 2022 and has applied since 1 May 2023.
Found what you need?
Document preview — GB/T 41682-2022
National Standard of the People's Republic of China
- ICS
- 83.140.01
- Classification
- G 31
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Terms and Definitions4
- 4 Principle5
- 5 Preparation of Sample5
- 6 Instrument5
- 7 Calibration7
- 8 Test Procedures7
- 9 Calculation of Results8
- 10 Expression of Results9
- 11 Test Report9
1 Scope
This Document describes a sensor-based method for the determination of different headspace gas contents in plastic packaging container for food.
This Document is applicable to the determination of the content of oxygen, carbon dioxide and other gases inside the packaging of food plastics and plastics and other materials composite materials that can be pierced by sampling needles. The detection of headspace gas in airtight packaging container of other materials can be carried out by reference of this Document.
2 Normative References
The provisions in following documents become the essential provisions of this Document through reference in this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document.
GB/T 2918 Plastics - Standard Atmospheres for Conditioning and Testing
ISO 2602:1980 Statistical Interpretation of Test Results - Estimation of the Mean - Confidence Interval
3 Terms and Definitions
For the purposes of this Document, the following terms and definitions apply.
3.1 Headspace gas
After the packaging containing food is sealed, a certain amount of gas remains or is filled inside the packaging.
NOTE: Depending on the packaging method, the pressure of the gas inside the package may be equal to or higher than the ambient atmospheric pressure, or maybe lower than the ambient atmospheric pressure.
6 Instrument
6.4 Sealing gasket
Assist the sampler to pierce the packaging to avoid breakage of the packaging material. If the elasticity of the material of the package to be sampled is sufficient to prevent leakage when the sampler penetrates, the sealing gasket may be exempted from use.
6.5 Sample injection port
Through the sample injection port, the sample gas in the sampler can be introduced into the detection device.
6.6 Sensor
Accurately detect the content of specific gases in the sample gas, and the detection accuracy does not exceed ±0.5% (volume fraction).
6.7 Pipeline
The gas flow path that is used to transmit the sample gas to be tested.
7 Calibration
Use standard gas for equipment calibration; and the corresponding standard gas shall be used for calibration of different gas analysis sensors. During calibration, the gas is drawn from the standard gas source and introduced into the detection device; and the sensor shall be calibrated with standard gases of different gas concentrations.
Usually, various gas analysis sensors use 99.99% nitrogen standard gas for zero calibration.
During the calibration process, the carbon dioxide analysis sensor shall use different concentrations of carbon dioxide standard gas according to the range of the sensor; the analysis sensors with three ranges of 0%~100%, 0%~20%, and 0%~5% can respectively use 25%, 10%, 3% carbon dioxide standard gas for calibration. Oxygen analysis sensor shall be calibrated with 21% oxygen standard gas.
8 Test Procedures
8.1 In accordance with the requirements of GB/T 2918, conduct the test in a laboratory environment at temperature of 23°C±2°C and relative humidity of 50%±10%. If there are other test requirements, it can be tested under the specified environmental conditions.
8.2 Stick the sealing gasket to the part of the sample to be tested; and pay attention to stick it firmly to prevent air leakage, as shown in Figure 3. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 2602:1980
Similar standards
How to Download GB/T 41682-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2918-2018 — Plastics -- Standard atmospheres for conditioning and testing
GB/T 29180.2-2012 — The investigative methods and procedures for electrical fire - Part 2: Methods for dissolution and separation of physical evidence
GB/T 29181-2024 — Terminology work - Computer applications - Terminological markup framework
Secure payment via Stripe
Payments accepted
GB/T 41682-2022
$150.00