GB/T 41073-2021Surface chemical analysis - Electron spectroscopies - Minimum reporting requirements for peak fitting in X-ray photoelectron spectroscopy (English PDF)

表面化学分析 电子能谱 X射线光电子能谱峰拟合报告的基本要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (37 pages)

Need quotation for your management?

Get a formal quotation for GB/T 41073-2021 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

December 31, 2021

Implementation date

July 1, 2022

Scope

GB/T 41073-2021 is the English-translated version of 表面化学分析 电子能谱 X射线光电子能谱峰拟合报告的基本要求.

GB/T 41073-2021 is the Chinese standard "Surface chemical analysis - Electron spectroscopies - Minimum reporting requirements for peak fitting in X-ray photoelectron spectroscopy".

Its scope clause reads: This document specifies how to report peak fits of X-ray photoelectron spectroscopy and their results: This document applies to the fitting of a single spectrum or a set of related spectra, such as a set of related spectra acquired in a depth profiling test: This document provides a list of parameters that should be reported in order to achieve reproducible peak fitting or to fit and compare multiple spectra: This document does not provide operating instructions for peak fitting, nor the fitting steps that should be taken:. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 41073-2021

National Standard of the People's Republic of China

Classification
G 04

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Symbols and Abbreviations
  • 5 Relevant data collection parameter report
  • 6 Single Spectrum Peak Fitting Parameter Report
  • 7 Multiplex Fitting
  • 8 satellite peak deduction
  • 9 Double Peaks Deduction
  • 10 Spectral deconvolution
  • 11 Fit quality and uncertainty
  • Appendix A (Informative) Reported Peak Fit Example
  • Appendix B (Informative) Multilayer Dataset Peak Fitting Report
  • Appendix C (Informative) Reported Peak Fitting Parameter Template
  • Appendix D (Informative) Statistical Methods

1 Scope

This document specifies how to report peak fits of X-ray photoelectron spectroscopy and their results:

This document applies to the fitting of a single spectrum or a set of related spectra, such as a set of related spectra acquired in a depth profiling test:

This document provides a list of parameters that should be reported in order to achieve reproducible peak fitting or to fit and compare multiple spectra:

This document does not provide operating instructions for peak fitting, nor the fitting steps that should be taken:

2 Normative references

There are no normative references in this document:

3 Terms and Definitions

The following terms and definitions apply to this document:

3:1

Inelastic background, inelastic

Due to single or multiple inelastic scattering processes, particles originally at one energy are now emitted at lower energies and appear more intense in the spectrum degree distribution:

[Source: ISO 18115-1, 4:50]

3:2

Shirley background, Shirley

The background calculated when fitting the measured spectrum at kinetic energies above and below this peak or meaningful peak, such that the background at a given kinetic energy is the same as

The total peak area at higher kinetic energies above background is a fixed proportion of the composition:

[Source: ISO 18115-1:2010, 4:54]

3:3

Tougaard background,Tougaard

Intensities obtained using a differential inelastic scattering cross-section model with respect to energy loss and a three-dimensional distribution model of emitting atoms in the surface region distributed:

[Source: ISO 18115-1:2010, 4:57]

3:4 passenergy

The average kinetic energy of the measured particle in the energy dispersive region located in the energy analyzer:

[Source: ISO 18115-1:2010, 4:325]

3:5 peak fitting

Steps to adjust the spectrum produced by peak synthesis to match the measured spectrum:

GB/T 40244 | GB/T 35924 | GB/T 35930 | GB/T 41072 | GB/T 41064 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 37 pages — is available in the English PDF.

How to Download GB/T 41073-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
37 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 41073-2021

$300.00