GB/T 4103.14-2009Methods for chemical analysis of lead and lead alloys - Part 14: Determination of cadmium content - Flame atomic absorption spectrophotometry (English PDF)
铅及铅合金化学分析方法 第14部分:镉量的测定 火焰原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 4103.14-2009 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
April 8, 2009
Implementation date
February 1, 2010
Scope
GB/T 4103.14-2009 is the English-translated version of 铅及铅合金化学分析方法 第14部分:镉量的测定 火焰原子吸收光谱法.
GB/T 4103.14-2009 is the Chinese standard "Methods for chemical analysis of lead and lead alloys -- Part 14: Determination of cadmium content -- Flame atomic absorption spectrophotometry".
Its scope clause reads: This Part of GB/T 4103 specifies the determination of cadmium content in lead and lead-cadmium alloys. This Part applies to the determination of cadmium content in lead and lead-cadmium alloys.
Measuring range. 0.000 1% -0.01%; 0.3% - 2.0%. Its clauses include methods and principles; reagents; instruments; analytical steps; calculation of analytical results; precision; quality assurance and control.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on APRIL 8, 2009 and took effect on FEBRUARY 1, 2010.
Found what you need?
Document preview — GB/T 4103.14-2009
National Standard of the People's Republic of China
- ICS
- 77.120.60
- Classification
- H 13
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface3
- 1 Scope5
- 2 Methods and Principles5
- 3 Reagents5
- 4 Instruments6
- 5 Analytical Steps7
- 6 Calculation of analytical results8
- 7 Precision9
- 8 Quality assurance and control10
- References and Original Chinese Documents11
1 Scope
This Part of GB/T 4103 specifies the determination of cadmium content in lead and lead-cadmium alloys.
This Part applies to the determination of cadmium content in lead and lead- cadmium alloys.
Measuring range: 0.000 1% -0.01%; 0.3% – 2.0%.
2 Methods and Principles
Samples shall be dissolved in nitrate; USE lead sulfate to precipitate and separate lead; USE air-acetylene flame, at wavelength 228.8 nm of atomic absorption spectrometer, to measure absorbance of cadmium. USE standard curve method to calculate cadmium content.
3 Reagents
Unless otherwise stated, water used to prepare the solution and analysis in this test shall be Grade 1 Water; all test utensils used in the test shall be immersed with dilute nitrate (1 + 4), and shall be thoroughly washed with Grade 1 Water.
3.1 Nitrate (rho 1.42 g / mL), superior grade purity.
3.2 Sulfate (rho 1.84 g / mL); superior grade purity.
3.3 Nitrate (1 + 1).
3.4 Nitrate (1 + 3).
3.5 Sulfate (1 + 1).
3.6 Cadmium standard storage solution: WEIGH 0.500 0 g of metal cadmium
(mass fraction of cadmium >= 99.99%) into 250 mL beaker; ADD 20 mL of nitrate (3.1); COVER with watch glass; HEAT it until completely dissolved; BOIL to expel nitrogen oxides; COOL it; MOVE into 1 000 mL volumetric flask; USE water to dilute the volume to the mark; SHAKE well. 1 mL of this solution contains 0.5 mg of cadmium.
3.7 Cadmium standard solution: PIPETTE 10.00 mL of cadmium standard
storage solution (3.6) into 500 mL volumetric flask; ADD 20 mL of nitrate (3.3);
USE water to dilute the volume to the mark; MIX well; 1 mL of this solution contains 10 µg of cadmium.
4 Instruments
Atomic absorption spectrometer, attached with cadmium hollow cathode lamp.
Under the optimum working conditions; those instruments which can achieve the following targets may be used.
- Characteristic concentration: In solution consistent with the matrix of measuring sample solution, the characteristic concentration of cadmium shall be less than 0.05 µg / mL;
- Precision: USE standard solution of the highest concentration to measure absorbance for 10 times, its standard deviation shall not exceed 1.0% of the average absorbance; USE standard solution of the lowest concentration (not the standard solution of “zero” concentration) to measure absorbance for 10 times, its standard deviation shall not exceed 0.5% of the average absorbance of standard solution of the highest concentration;
- Linearity of working curve: DIVIDE the working curve into five sections equally, based on concentration; the ratio between the absorbance difference of the highest section AND the absorbance difference of the lowest section shall not be less than 0.8;
Reference operating conditions of the instruments are shown in Table 1.
Table 4
Mass factor of cadmium / %
0.0002
0.0020 0.0050
0.50 1.00 1.50
R / % 0.0001
0.0005 0.0010
0.04 0.05 0.06
Note: Reproducibility (R) is 2.8SR; SR is the reproducibility standard deviation.
8 Quality assurance and control
Standard samples of national-level or industrial-level shall be used (when these
2 samples are not available, controlled standard sample may be used for substitution); effectiveness of this analytical method shall be calibrated weekly or biweekly. When the process is out of control, root cause shall be found out;
After the error is corrected, calibration shall be repeated.
_________________________
References and Original Chinese Documents
[1] GB/T 4103.14-2009 Methods for chemical analysis of lead and lead alloys - Part
14: Determination of cadmium content - Flame atomic absorption
ID=GB/T%204103.14-2009
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 4103.14-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 4103.15-2009 — Methods for chemical analysis of lead and lead alloys - Part 15: Determination of nickel content - Flame atomic absorption spectrophotometry
GB/T 4103.13-2000 — Methods for chemical analysis of lead and lead alloys Determination of aluminium content
GB/T 4103.16-2009 — Methods for chemical analysis of lead and lead alloys - Part 16: Determination of copper, silver, bismuth, arsenic, antimony, tin and zinc contents - Optical emission spectrometry
Secure payment via Stripe
Payments accepted
GB/T 4103.14-2009
$75.00