Scope
GB/T 4074.21-2018 is the English-translated version of 绕组线试验方法 第21部分:耐高频脉冲电压性能.
GB/T 4074.21-2018 is Part 21 of the Chinese test methods for winding wires and covers electrical endurance under high-frequency voltage impulses, also known as the corona resistance test.
It measures how long a winding wire withstands repeated high-frequency pulse voltage in atmospheric air, and sets out the terms used, such as bipolar impulse, impulse-voltage repetition rate, peak impulse voltage and steady-state impulse voltage magnitude, the tester with its independent power supply, timing device and heating oven, specimen preparation and power-frequency AC screening, test parameters and records.
It applies to corona-resistant enamelled round wire, grade-240 aromatic corona-resistant polyimide film wrapped sintered round and flat wire, glass fibre wrapped film flat wire and mica tape wrapped flat wire. It was issued on 15 March 2018 and has applied since 1 October 2018.
Found what you need?
Document preview — GB/T 4074.21-2018
National Standard of the People's Republic of China
- ICS
- 29.060.10
- Classification
- K 12
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope5
- 2 Normative references5
- 3 Terms and definitions5
- 4 General provisions for testing8
- 5 High frequency pulse voltage tester8
- 6 Specimen10
- 7 Test11
- Appendix A (Informative) Method for verifying polarity of output waveform of equipment15
- References18
1 Scope
This part of GB/T 4074 stipulates the test method (also known as corona resistance test method) for using high-frequency pulse voltage to determine the resistance of the winding wire to high-frequency pulse voltage in atmospheric air, including the terms and definitions of the test, test equipment, specimen preparation, test procedures, test parameters and test records.
This part applies to the following winding wires.
- Corona-resistant enameled round winding wire;
- Grade-240 aromatic corona-resistant polyimide film wrapped sintered round and flat winding wire;
- Glass fiber wrapped film winding flat winding wire;
- Mica tape wrapped flat winding wire.
2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard.
GB/T 4074.5-2008 Winding wires - Test methods - Part 5: Electrical properties
GB/T 4074.7-2009 Winding wires - Test methods - Part 7: Test procedure for the determination of the temperature index of enameled winding wires
GB/T 30435 Electric gravity convection and forced ventilation ovens
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Bipolar impulse
For voltage pulses, the polarity alternates from positive to negative or from negative to positive.
3.2 Impulse-voltage repetition rate
Regardless of unipolar or bipolar pulses, at the same time interval, the reciprocal of the time between two consecutive complete pulses. [IEC 62068:2013, definition 3.14]
3.5 Peak impulse voltage
The maximum voltage value reached during the unipolar surge voltage period (see Figure 1).
Note: For bipolar pulse voltage, the pulse peak voltage is half of the pulse peak-peak voltage (Upk/pk). The pulse peak-peak voltage (Upk/pk) is as shown in Figure 1.
3.6 Steady-state impulse voltage magnitude
The final value of the impulse voltage (see Figure 1).
4 General provisions for testing
4.1 Test principle
For the test conditions and test requirements not specified in this part, they shall be carried out in accordance with the product standard.
4.2 Standard environment for specimen state conditioning and testing
4.2.1 When the test winding wire is removed from the spool, it shall neither withstand tension or unnecessary bending, nor shall it be contaminated by the outside.
5 High frequency pulse voltage tester
5.1 Composition of tester
It shall include the following three parts. test power supply, timing device and hot state tester.
5.2 Test power
Each specimen shall use an independent power supply during the test. The test equipment shall meet the following parameter requirements under load conditions.
5.3 Timing device
Each specimen shall be timed separately. When the tested specimen is short-circuited, the timer stops counting and records the test value.
5.4 Hot state tester
The electric heating oven used for the test shall meet the requirements of GB/T 30435. Room temperature ~ 200 °C, temperature deviation is ± 3 °C.
6 Specimen
6.1 Corona-resistant round winding wire
6.1.1 Product types
Corona-resistant enameled round winding wire suitable for conductors which have a nominal diameter greater than 0.250 mm and less than or equal to 1.600 mm as well as the grade-240 aromatic corona-resistant polyimide film wrapped sintered round winding wire.
6.1.2 Specimen preparation
For the grade-240 aromatic corona-resistant polyimide film wrapped sintered round winding wire, prepare specimen according to the provisions of 5.1.2 in GB/T 4074.7-2009.
6.1.3 Specimen screening
6.1.3.1 Grade-240 aromatic corona-resistant polyimide film wrapped sintered round winding wire
6.1.3.2 Corona-resistant enameled round winding wire
For the corona-resistant enameled round winding wire, in order to ensure the uniform performance of the same batch of specimens, all specimens shall be subject to power frequency AC withstanding voltage test screening according to the voltage specified in Table 1, before the high-frequency pulse resistance test. The voltage duration is 1 s.
6.1.4 Test sample
Only the samples that pass the screening of 6.1.3 power frequency AC withstanding voltage test can be subjected to the high frequency pulse test in Chapter 7.
6.2 Flat winding wire
Scope of application. Glass fiber wrapped film wrapped flat winding wire, mica tape wrapped flat winding wire and grade-240 aromatic corona-resistant polyimide film wrapped sintered flat winding wire.
7 Test
7.1 Corona-resistant enameled round winding wire
7.1.1 Product types
Only suitable for corona-resistant enameled round winding wires which has a paint film thickness of grade 2 and 3.
7.1.2 Main parameters of high frequency impulse voltage resistance
See Table 2 for the test parameters of the corona-resistant enameled round
7.1.3 Test procedure
Prepare specimen according to the provisions of 6.1 and conduct power frequency AC voltage withstanding test.
7.1.4 Test results
Test 5 specimens. Record the test results. Take the minimum value and intermediate values.
7.2 Grade-240 aromatic corona-resistant polyimide film wrapped sintered round and flat winding wire
7.2.1 Main parameters of high-frequency impulse voltage resistance
See Table 4 for test parameters of grade-240 aromatic corona-resistant polyimide film wrapped sintered winding wire's resistance to high-frequency pulse voltage.
7.3 Glass fiber film wrapped flat winding wire and mica tape wrapped flat winding wire
7.3.1 Main parameters of high-frequency pulse voltage resistance
See Table 6 for the test parameters of resistance to high-frequency impulse voltage performance of glass fiber film wrapped flat winding wire and mica tape wrapped flat winding wire.
7.3.2 Test procedure
Prepare specimens according to the provisions of 6.2 and conduct power frequency AC voltage withstanding test.
7.3.3 Test results
Test 5 specimens. Record the test results. Take the minimum value and intermediate values. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 4074.21-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 30435-2013 — Electric gravity convection and forced ventilation ovens
GB/T 4074.1-2024 — Test methods of winding wires - Part 1: General
GB/T 4074.2-2024 — Test methods of winding wires - Part 2: Determination of dimensions
Secure payment via Stripe
Payments accepted
GB/T 4074.21-2018
$185.00